Power transformer is one of the most important equipment in the power system.Its operating condition affects the reliability of power supply directly.Therefore,in order to guarantee transformer operation safely and re...Power transformer is one of the most important equipment in the power system.Its operating condition affects the reliability of power supply directly.Therefore,in order to guarantee transformer operation safely and reliably,it is necessary to assess condition of power transformer accurately.Return voltage method based on voltage response measurements is still a new non-intrusive diagnosis method for internal insulation aging of transformer.In this paper the technique and application of return voltage measurement and some results of voltage response measurements of several transformers was introduced.Voltage response measurements were performed on various transformers with different voltage grades,various operating periods,different moisture contents and aging degrees on site.Derived moisture contents from return voltage measurement were compared with the corresponding moisture contents obtained from the analysis of oil samples.Based on on-site experiments and theoretical analysis,the criteria for insulation state of transformer are proposed.Moisture condition of transformer insulation can be determined by using return dominant time constant,and a good correlation between aging degree and the return voltage initial slopes of the aged transformers.Field test performed on several transformers,its interpretation of results are also presented,which proves that return voltage measurements can be used as a reliable tool for evaluating moisture content in transformer insulation.展开更多
通过监测护层电流可及早发现高压电力电缆线路的潜在故障,有效避免非计划性停电。为此,提出了1种可用于诊断故障与非故障情况下3相交叉互联高压电力电缆中护层电流的研究方案。通过建立数学模型详细分析了2种典型的电缆故障,并基于1条...通过监测护层电流可及早发现高压电力电缆线路的潜在故障,有效避免非计划性停电。为此,提出了1种可用于诊断故障与非故障情况下3相交叉互联高压电力电缆中护层电流的研究方案。通过建立数学模型详细分析了2种典型的电缆故障,并基于1条线路长度为1.5 km、电压等级为110 k V的隧道电缆的仿真计算,提出了1套适用于12种电缆故障的诊断及定位标准。仿真分析结果显示:当电缆接地系统中存在开路故障时,故障回路中的护层电流会降低;而当电缆交叉互联箱进水或电缆接头内环氧预制件击穿时,故障护层回路中将产生高于正常水平的护层电流值。基于故障仿真,所提出的故障诊断标准可准确识别并定位指定的3种电缆故障:接头松动导致护层开路、交叉互联箱进水和接头内环氧预制件击穿。仿真表明地电阻的大幅度变化会导致诊断标准发生变化。展开更多
基金Project Supported by Science and Technology Fund of Fujian E-lectric Power Limited Company(NC2006044)Scientific Research Fund of Fujian Education Depart ment(JB06045)
文摘Power transformer is one of the most important equipment in the power system.Its operating condition affects the reliability of power supply directly.Therefore,in order to guarantee transformer operation safely and reliably,it is necessary to assess condition of power transformer accurately.Return voltage method based on voltage response measurements is still a new non-intrusive diagnosis method for internal insulation aging of transformer.In this paper the technique and application of return voltage measurement and some results of voltage response measurements of several transformers was introduced.Voltage response measurements were performed on various transformers with different voltage grades,various operating periods,different moisture contents and aging degrees on site.Derived moisture contents from return voltage measurement were compared with the corresponding moisture contents obtained from the analysis of oil samples.Based on on-site experiments and theoretical analysis,the criteria for insulation state of transformer are proposed.Moisture condition of transformer insulation can be determined by using return dominant time constant,and a good correlation between aging degree and the return voltage initial slopes of the aged transformers.Field test performed on several transformers,its interpretation of results are also presented,which proves that return voltage measurements can be used as a reliable tool for evaluating moisture content in transformer insulation.
文摘通过监测护层电流可及早发现高压电力电缆线路的潜在故障,有效避免非计划性停电。为此,提出了1种可用于诊断故障与非故障情况下3相交叉互联高压电力电缆中护层电流的研究方案。通过建立数学模型详细分析了2种典型的电缆故障,并基于1条线路长度为1.5 km、电压等级为110 k V的隧道电缆的仿真计算,提出了1套适用于12种电缆故障的诊断及定位标准。仿真分析结果显示:当电缆接地系统中存在开路故障时,故障回路中的护层电流会降低;而当电缆交叉互联箱进水或电缆接头内环氧预制件击穿时,故障护层回路中将产生高于正常水平的护层电流值。基于故障仿真,所提出的故障诊断标准可准确识别并定位指定的3种电缆故障:接头松动导致护层开路、交叉互联箱进水和接头内环氧预制件击穿。仿真表明地电阻的大幅度变化会导致诊断标准发生变化。