A distributed local adaptive transmit power assignment (LA-TPA) strategy was proposed to construct a topology with better performance according to the environment and application scenario and prolong the network lifet...A distributed local adaptive transmit power assignment (LA-TPA) strategy was proposed to construct a topology with better performance according to the environment and application scenario and prolong the network lifetime.It takes the path loss exponent and the energy control coefficient into consideration with the aim to accentuate the minimum covering district of each node more accurately and precisely according to various network application scenarios.Besides,a self-healing scheme that enhances the robustness of the network was provided.It makes the topology tolerate more dead nodes than existing algorithms.Simulation was done under OMNeT++ platform and the results show that the LA-TPA strategy is more effective in constructing a well-performance network topology based on various application scenarios and can prolong the network lifetime significantly.展开更多
There are abundant water power resources in the Yalong River which are suitable for the large hydroelectric engineering. But a reliability study should be made for the valley which liable to frequent earthquakes. The ...There are abundant water power resources in the Yalong River which are suitable for the large hydroelectric engineering. But a reliability study should be made for the valley which liable to frequent earthquakes. The color infrared aerophotos, multi-spectral photography and thermal infrared scanning had been specially done besides MSS image, processing. Researches on remote sensing applications to engineering geology, hydrogeology, deformation of neo-tectonics, Iandslide, mud-rock flow, ecological environment and geographical information system had been carried out by more than 20 research units.展开更多
An improved method for calculating the corona power loss and the ground-level electric field on HVAC transmission lines induced by corona is proposed.Based on a charge simulation method combined with a method of succe...An improved method for calculating the corona power loss and the ground-level electric field on HVAC transmission lines induced by corona is proposed.Based on a charge simulation method combined with a method of successive images,the proposed method has the number and location of the simulated charges not arbitrary.When the surface electric field of a conductor exceeds the onset value,charges are emitted from corona into the space around,and the space ions and the surface charges on each sub-conductor are simulated by using the images of the other sub-conductors.The displacements of the space ions are calculated at every time step during corona periods in both the positive and the negative half cycles.Several examples are calculated by using the proposed method,and the calculated electric field at the ground level and the corona power loss agree well with previous measurements.The results show that simulating 12 charges in each conductor during 600 time steps in one cycle takes less time while guarantees the accuracy.The corona discharge from a 220 kV transmission line enhances slightly(less than 2%) the electric field at the ground level,but this effect is little from a 500 kV line.The improved method is a good compromise between the time cost and the accuracy of calculation.展开更多
To reduce the negative impact of the power amplifier(PA)nonlinear distortion caused by the orthogonal frequency division multiplexing(OFDM)waveform with high peak-to-average power ratio(PAPR)in integrated radar and co...To reduce the negative impact of the power amplifier(PA)nonlinear distortion caused by the orthogonal frequency division multiplexing(OFDM)waveform with high peak-to-average power ratio(PAPR)in integrated radar and communication(RadCom)systems is studied,the channel estimation in passive sensing scenarios.Adaptive channel estimation methods are proposed based on different pilot patterns,considering nonlinear distortion and channel sparsity.The proposed methods achieve sparse channel results by manipulating the least squares(LS)frequency-domain channel estimation results to preserve the most significant taps.The decision-aided method is used to optimize the sparse channel results to reduce the effect of nonlinear distortion.Numerical results show that the channel estimation performance of the proposed methods is better than that of the conventional methods under different pilot patterns.In addition,the bit error rate performance in communication and passive radar detection performance show that the proposed methods have good comprehensive performance.展开更多
虚拟电厂(virtual power plant,VPP)可利用异构网络实现分布式新能源聚合调度,实现综合效益提升。为了提高VPP在不同网络下的丢包与时延等非理想传输能力,提出面向异构通信网络的设备接入优化算法。首先,分析总结了VPP设备充放电容量、...虚拟电厂(virtual power plant,VPP)可利用异构网络实现分布式新能源聚合调度,实现综合效益提升。为了提高VPP在不同网络下的丢包与时延等非理想传输能力,提出面向异构通信网络的设备接入优化算法。首先,分析总结了VPP设备充放电容量、出力特性、接入网络时延、网络承载能力等约束条件,考虑异构网络下设备接入的丢包率和时延理论性能构建了以收益损失最小化为目标的优化模型。然后,利用分层求解和贪婪算法进行模型求解,获得设备的接入方式。最后,仿真验证了所提模型和算法的有效性和可靠性。结果表明,所提算法可提高网络接入容量并降低系统收益损失,实现收益最大化。展开更多
基金Projects(61101104,61100213) supported by the National Natural Science Foundation of ChinaProject(NY211050) supported by Fund of Nanjing University of Posts and Telecommunications,China
文摘A distributed local adaptive transmit power assignment (LA-TPA) strategy was proposed to construct a topology with better performance according to the environment and application scenario and prolong the network lifetime.It takes the path loss exponent and the energy control coefficient into consideration with the aim to accentuate the minimum covering district of each node more accurately and precisely according to various network application scenarios.Besides,a self-healing scheme that enhances the robustness of the network was provided.It makes the topology tolerate more dead nodes than existing algorithms.Simulation was done under OMNeT++ platform and the results show that the LA-TPA strategy is more effective in constructing a well-performance network topology based on various application scenarios and can prolong the network lifetime significantly.
文摘There are abundant water power resources in the Yalong River which are suitable for the large hydroelectric engineering. But a reliability study should be made for the valley which liable to frequent earthquakes. The color infrared aerophotos, multi-spectral photography and thermal infrared scanning had been specially done besides MSS image, processing. Researches on remote sensing applications to engineering geology, hydrogeology, deformation of neo-tectonics, Iandslide, mud-rock flow, ecological environment and geographical information system had been carried out by more than 20 research units.
基金supported by National Basic Research Program of China(973 Program)(2011CB209404)
文摘An improved method for calculating the corona power loss and the ground-level electric field on HVAC transmission lines induced by corona is proposed.Based on a charge simulation method combined with a method of successive images,the proposed method has the number and location of the simulated charges not arbitrary.When the surface electric field of a conductor exceeds the onset value,charges are emitted from corona into the space around,and the space ions and the surface charges on each sub-conductor are simulated by using the images of the other sub-conductors.The displacements of the space ions are calculated at every time step during corona periods in both the positive and the negative half cycles.Several examples are calculated by using the proposed method,and the calculated electric field at the ground level and the corona power loss agree well with previous measurements.The results show that simulating 12 charges in each conductor during 600 time steps in one cycle takes less time while guarantees the accuracy.The corona discharge from a 220 kV transmission line enhances slightly(less than 2%) the electric field at the ground level,but this effect is little from a 500 kV line.The improved method is a good compromise between the time cost and the accuracy of calculation.
基金supported by the National Natural Science Foundation of China(61931015,62071335,62250024)the Natural Science Foundation of Hubei Province of China(2021CFA002)+1 种基金the Fundamental Research Funds for the Central Universities of China(2042022dx0001)the Science and Technology Program of Shenzhen(JCYJ20170818112037398).
文摘To reduce the negative impact of the power amplifier(PA)nonlinear distortion caused by the orthogonal frequency division multiplexing(OFDM)waveform with high peak-to-average power ratio(PAPR)in integrated radar and communication(RadCom)systems is studied,the channel estimation in passive sensing scenarios.Adaptive channel estimation methods are proposed based on different pilot patterns,considering nonlinear distortion and channel sparsity.The proposed methods achieve sparse channel results by manipulating the least squares(LS)frequency-domain channel estimation results to preserve the most significant taps.The decision-aided method is used to optimize the sparse channel results to reduce the effect of nonlinear distortion.Numerical results show that the channel estimation performance of the proposed methods is better than that of the conventional methods under different pilot patterns.In addition,the bit error rate performance in communication and passive radar detection performance show that the proposed methods have good comprehensive performance.
文摘虚拟电厂(virtual power plant,VPP)可利用异构网络实现分布式新能源聚合调度,实现综合效益提升。为了提高VPP在不同网络下的丢包与时延等非理想传输能力,提出面向异构通信网络的设备接入优化算法。首先,分析总结了VPP设备充放电容量、出力特性、接入网络时延、网络承载能力等约束条件,考虑异构网络下设备接入的丢包率和时延理论性能构建了以收益损失最小化为目标的优化模型。然后,利用分层求解和贪婪算法进行模型求解,获得设备的接入方式。最后,仿真验证了所提模型和算法的有效性和可靠性。结果表明,所提算法可提高网络接入容量并降低系统收益损失,实现收益最大化。