Traditional gust load factor(GLF)method,inertial wind load(IWL)method and tri-component method(LRC+IWL)cannot accurately analyze the wind-induced responses of super-large cooling towers,so the real combination formula...Traditional gust load factor(GLF)method,inertial wind load(IWL)method and tri-component method(LRC+IWL)cannot accurately analyze the wind-induced responses of super-large cooling towers,so the real combination formulas of fluctuating wind-induced responses and equivalent static wind loads(ESWLSs)were derived based on structural dynamics and random vibration theory.The consistent coupled method(CCM)was presented to compensate the coupled term between background and resonant response.Taking the super-large cooling tower(H=215 m)of nuclear power plant in Jiangxi Province,China,which is the highest and largest in China,as the example,based on modified equivalent beam-net design method,the aero-elastic model for simultaneous pressure and vibration measurement of super-large cooling tower is firstly carried out.Then,combining wind tunnel test and CCM,the effects of self-excited force on the surface pressures and wind-induced responses are discussed,and the wind-induced response characteristics of background component,resonant component,coupled term between background and resonant response,fluctuating responses,and wind vibration coefficients are discussed.It can be concluded that wind-induced response mechanism must be understood to direct the wind resistant design for super-large cooling towers.展开更多
Most of modern tall buildings using lighter construction materials with high strength and less stiffness are more flexible, which occurs excessive wind-induced vibration, resulting in occupant discomfort and structura...Most of modern tall buildings using lighter construction materials with high strength and less stiffness are more flexible, which occurs excessive wind-induced vibration, resulting in occupant discomfort and structural unsafety. It is necessary to predict wind-induced vibration response and find out a method to mitigate such an excessive wind-induced vibration at the preliminary design stage. Recently, many studies have been conducted in using actuator control force based on the linear quadratic optimum control algorithm. It was accepted as a common knowledge that the performance of passive tuned mass damper(TMD) could increase by incorporating a feedback active control force in the design of TMD, which is called active tuned mass damper(ATMD). However, the fact that ATMD is superior to TMD to reduce wind-induced vibration of a tall building is still a question. The effectiveness of TMD for mitigating the along-wind vibration of a tall building was investigated. Optimum parameters of tuning frequency and damping ratio for TMD under a random load which has a white noise spectra were used. Fluctuating along-wind load acting on a tall building treated as a stationary Gaussian random process was simulated numerically using the along-wind load spectra. And using this simulated along-wind load, along-wind responses of a tall building with and without TMD were calculated and the effectiveness of TMD in mitigating the along-wind response of a tall building was found out.展开更多
In order to study the dynamic response of concrete-filled steel tube(CFST) columns against blast loads,a simplified model is established utilizing the equivalent single-degree-of-freedom(SDOF) method,which considers t...In order to study the dynamic response of concrete-filled steel tube(CFST) columns against blast loads,a simplified model is established utilizing the equivalent single-degree-of-freedom(SDOF) method,which considers the non-uniform distribution of blast loads on real column and the axial load-bending moment(P-M) interaction of CFST columns.Results of the SDOF analysis compare well with the experimental data reported in open literature and the values from finite element modeling(FEM) using the program LS-DYNA.Further comparisons between the results of SDOF and FEM analysis show that the proposed model is effective to predict the dynamic response of CFST columns with different blast conditions and column details.Also,it is found that the maximum responses of the columns are overestimated when ignoring the non-uniformity of blast loads,and that neglecting the effect of P-M interaction underestimates the maximum response of the columns with large axial load ratio against close range blast.The proposed SDOF model can be used in the design of the blast-loaded CFST columns.展开更多
基金Projects(50978203,51208254)supported by the National Natural Science Foundation of ChinaProject(BK2012390)supported by Natural Science Foundation of Jiangsu Province,ChinaProject supported by the Priority Academic Program Development of Jiangsu Higher Education Institutions,China
文摘Traditional gust load factor(GLF)method,inertial wind load(IWL)method and tri-component method(LRC+IWL)cannot accurately analyze the wind-induced responses of super-large cooling towers,so the real combination formulas of fluctuating wind-induced responses and equivalent static wind loads(ESWLSs)were derived based on structural dynamics and random vibration theory.The consistent coupled method(CCM)was presented to compensate the coupled term between background and resonant response.Taking the super-large cooling tower(H=215 m)of nuclear power plant in Jiangxi Province,China,which is the highest and largest in China,as the example,based on modified equivalent beam-net design method,the aero-elastic model for simultaneous pressure and vibration measurement of super-large cooling tower is firstly carried out.Then,combining wind tunnel test and CCM,the effects of self-excited force on the surface pressures and wind-induced responses are discussed,and the wind-induced response characteristics of background component,resonant component,coupled term between background and resonant response,fluctuating responses,and wind vibration coefficients are discussed.It can be concluded that wind-induced response mechanism must be understood to direct the wind resistant design for super-large cooling towers.
基金Project(2011-0028567)supported by the National Research Foundation of Korea
文摘Most of modern tall buildings using lighter construction materials with high strength and less stiffness are more flexible, which occurs excessive wind-induced vibration, resulting in occupant discomfort and structural unsafety. It is necessary to predict wind-induced vibration response and find out a method to mitigate such an excessive wind-induced vibration at the preliminary design stage. Recently, many studies have been conducted in using actuator control force based on the linear quadratic optimum control algorithm. It was accepted as a common knowledge that the performance of passive tuned mass damper(TMD) could increase by incorporating a feedback active control force in the design of TMD, which is called active tuned mass damper(ATMD). However, the fact that ATMD is superior to TMD to reduce wind-induced vibration of a tall building is still a question. The effectiveness of TMD for mitigating the along-wind vibration of a tall building was investigated. Optimum parameters of tuning frequency and damping ratio for TMD under a random load which has a white noise spectra were used. Fluctuating along-wind load acting on a tall building treated as a stationary Gaussian random process was simulated numerically using the along-wind load spectra. And using this simulated along-wind load, along-wind responses of a tall building with and without TMD were calculated and the effectiveness of TMD in mitigating the along-wind response of a tall building was found out.
基金Project(KJZH14220)supported by the Achievement Transfer Program of Institutions of Higher Education in Chongqing,China
文摘In order to study the dynamic response of concrete-filled steel tube(CFST) columns against blast loads,a simplified model is established utilizing the equivalent single-degree-of-freedom(SDOF) method,which considers the non-uniform distribution of blast loads on real column and the axial load-bending moment(P-M) interaction of CFST columns.Results of the SDOF analysis compare well with the experimental data reported in open literature and the values from finite element modeling(FEM) using the program LS-DYNA.Further comparisons between the results of SDOF and FEM analysis show that the proposed model is effective to predict the dynamic response of CFST columns with different blast conditions and column details.Also,it is found that the maximum responses of the columns are overestimated when ignoring the non-uniformity of blast loads,and that neglecting the effect of P-M interaction underestimates the maximum response of the columns with large axial load ratio against close range blast.The proposed SDOF model can be used in the design of the blast-loaded CFST columns.