钢筋正截面抗弯承载力极限测试 被引量:1
1
作者 李冉 赵云丽 侯风 《兵器材料科学与工程》 CAS CSCD 北大核心 2024年第4期42-47,共6页
用HRB400钢筋为纵向受拉钢筋、HPB235钢筋为纵向受压钢筋,浇筑混凝土,制备配筋率分别为0.57%、1.01%、1.58%的3种建筑钢筋试件。对试件加载,测试每组试件的抗弯承载力。结果表明:当配筋率为0.57%时,试件的跨中挠度较大,易出现疲劳和损伤... 用HRB400钢筋为纵向受拉钢筋、HPB235钢筋为纵向受压钢筋,浇筑混凝土,制备配筋率分别为0.57%、1.01%、1.58%的3种建筑钢筋试件。对试件加载,测试每组试件的抗弯承载力。结果表明:当配筋率为0.57%时,试件的跨中挠度较大,易出现疲劳和损伤,且钢筋应变较小,刚度退化较严重,正截面裂缝宽度较高;当配筋率为1.58%时,试件的抗弯承载力极限可达238.64 kN,为较高水平,且试件的正截面屈服弯矩与开裂弯矩较高,当受到较大载荷时,钢筋试件的应变水平良好。由此可见,当配筋率为1.58%时,建筑钢筋正截面抗弯承载力较好。 展开更多
关键词 钢筋正截面 抗弯承载力 配筋率 跨中挠度 裂缝宽度 屈服弯矩
在线阅读 下载PDF
Properties and calculation of normal section bearing capacity of RC flexural beam with skin textile reinforcement 被引量:2
2
作者 尹世平 吕恒林 徐世烺 《Journal of Central South University》 SCIE EI CAS 2013年第6期1731-1741,共11页
In order to overcome the wide crack of ordinary reinforced concrete (RC) at service stage which affects the service performance and durability of structures,a kind of concrete structure with skin textile reinforcement... In order to overcome the wide crack of ordinary reinforced concrete (RC) at service stage which affects the service performance and durability of structures,a kind of concrete structure with skin textile reinforcement is proposed,namely a part of concrete cover of RC members is replaced by textile reinforced concrete (TRC).The flexural experimental results indicate that when the reinforcement ratios of steel bars are constant,compared with control beams,the average value of crack loads of the beams,whose reinforcement ratios of textile are 0.018%,0.036% and 0.055%,increases by 15.5%,20.4% and 31.1%,respectively,the average value of yield loads respectively increases by 12.5%,19.9% and 21.1% and the average value of ultimate loads respectively increases by 8.5%,26.0% and 44.0%,respectively.Considerable reduction in cracks width and spacing is observed for specimens with a TRC layer,and when the beams yield,the maximum crack width of the beam with textile stuck no sand and the beam with textile stuck sand is reduced by around 60% and 70%,respectively.Surface treatment of textile and mixing polypropylene fiber into fine grained concrete contribute to enhance the service performance of the flexural element.Embedding U-shaped hoop has almost no effect on the control of the crack width.Finally,the calculation method of ultimate bearing capacity of this flexural component with TRC layer was presented.Comparison between the calculated and the experimental values reveals satisfactory agreement,and the maximum error is no more than 6%. 展开更多
关键词 reinforced concrete TEXTILE crack width limitation flexural behavior calculation of flexural capacity
在线阅读 下载PDF