计及故障重构的配电网量测系统鲁棒性配置 被引量:8
1
作者 王红 张文 冯宗英 《电力系统自动化》 EI CSCD 北大核心 2016年第16期98-104,共7页
针对网络重构对配电网状态估计精度的影响,在分析量测饱和特性的基础上,提出了一种量测系统的鲁棒性配置方法。该方法综合考虑不同故障重构后的多种网络结构,利用马尔可夫链确定其运行概率,并作为权重引入鲁棒性量测配置的数学模型中,... 针对网络重构对配电网状态估计精度的影响,在分析量测饱和特性的基础上,提出了一种量测系统的鲁棒性配置方法。该方法综合考虑不同故障重构后的多种网络结构,利用马尔可夫链确定其运行概率,并作为权重引入鲁棒性量测配置的数学模型中,利用蒙特卡洛算法模拟量测系统引起的误差。IEEE 33节点配电系统和美国PG&E 69节点配电系统的仿真结果表明,所提出的鲁棒性配置方法可兼顾多种网络结构,并有效提高配电网状态估计的精度。 展开更多
关键词 量测饱和 鲁棒性配置 状态估计 马尔可夫链 网络重构
在线阅读 下载PDF
Online dynamic measurement of saturation-capillary pressure relation in sandy medium under water level fluctuation 被引量:1
2
作者 李雁 周劲风 +1 位作者 徐军 KAMON M 《Journal of Central South University》 SCIE EI CAS 2010年第1期85-92,共8页
An online dynamic method based on electrical conductivity probe, tensiometer and datataker was presented to measure saturation-capillary pressure (S-p) relation in water-light nonaqueous phase liquid (LNAPL) two-p... An online dynamic method based on electrical conductivity probe, tensiometer and datataker was presented to measure saturation-capillary pressure (S-p) relation in water-light nonaqueous phase liquid (LNAPL) two-phase sandy medium under water level fluctuation. Three-electrode electrical conductivity probe (ECP) was used to measure water saturation. Hydrophobic tensiometer was obtained by spraying waterproof material to the ceramic cup of commercially available hydrophilic tensiometer. A couple of hydrophilic tensiometer and hydrophobic tensiometer were used to measure pore water pressure and pore LNAPL pressure of the sandy medium, respectively. All the signals from ECP and tensiometer were collected by a data taker connected with a computer. The results show that this method can finish the measurement of S-R relation of a complete drainage or imbibition process in less than 60 min. It is much more timesaving compared with 10-40 d of traditional methods. Two cycles of water level fluctuation were produced, and four saturation-capillary pressure relations including two stable residual LNAPL saturations of the sandy medium were obtained during in 350 h. The results show that this method has a good durable performance and feasibility in the porous medium with complicated multiphase flow. Although further studies are needed on the signal stability and accuracy drift of the ECP, this online dynamic method can be used successfully in the rapid characterization of a LNAPL migration in porous media. 展开更多
关键词 water level fluctuation saturation-capillary pressure (S-p) relation online dynamic measurement
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部