选煤厂能耗标准与节能降耗技术研究 被引量:12
1
作者 赵树彦 任利勤 《中国煤炭》 2022年第6期44-49,共6页
在“能耗双控”的政策指引下,选煤厂高标准节能降耗势在必行。介绍了目前我国选煤厂节能降耗标准建设现状,分析了选煤厂电耗物耗的来源和在节能降耗方面存在的主要问题;有些选煤厂在电耗、水耗等能耗物耗标准建设上存在整体标准偏低、... 在“能耗双控”的政策指引下,选煤厂高标准节能降耗势在必行。介绍了目前我国选煤厂节能降耗标准建设现状,分析了选煤厂电耗物耗的来源和在节能降耗方面存在的主要问题;有些选煤厂在电耗、水耗等能耗物耗标准建设上存在整体标准偏低、标准不健全和工艺不合理等问题。提出选煤厂节能降耗具体举措;认为,采用先进的选煤技术工艺及其装备非常关键,并对新型高效原料煤不预排矸、不分级、不脱泥无压给料三产品重介质选煤技术工艺先进的节能降耗性能、关键技术及装备进行了系统阐述,介绍了其工业应用效果。 展开更多
关键词 选煤厂 选煤节能降耗标准建设 简单高效选煤工艺 超级重介质旋流器
在线阅读 下载PDF
Energy saving effect of building envelope in summer 被引量:1
2
作者 王厚华 郭锐 肖秋连 《Journal of Central South University》 SCIE EI CAS 2012年第5期1370-1376,共7页
To explore the energy saving effect of building envelope, the experiments were carried out through a comparison of basic cubicle in summer. Experiments show that if energy efficiency measures are applied only in the e... To explore the energy saving effect of building envelope, the experiments were carried out through a comparison of basic cubicle in summer. Experiments show that if energy efficiency measures are applied only in the external walls and windows, the energy saving cubicles have an average energy efficiency ratio of 27.75% and 27.05% when the air change rates are 1.1 and 1.4 h-1 in summer, with both values being over the standard target value by 25%. And the indoor air temperature of the energy saving cubicle is below that of the basic cubicle. The daily mean temperature difference between the interior surface of insulation wall and no insulation reaches 1.47℃, and the mean temperature difference is up to 8.52℃ between the interior surface and exterior surface of insulating glass and single glass. The two cubicles were simulated for energy consumption using VisualDOE4.0 software under real weather conditions in summer. The results show that the mean deviation is 10.02% between experimental and simulated energy efficiency ratio. The correctness and validity of simulation results of the VisualDOE4.0 software are proved. 展开更多
关键词 building energy conservation energy efficiency rate thermal performance air change rate
在线阅读 下载PDF
Weighting indicators of building energy efficiency assessment taking account of experts' priority 被引量:10
3
作者 杨玉兰 邰惠鑫 施韬 《Journal of Central South University》 SCIE EI CAS 2012年第3期803-808,共6页
Analytic hierarchy process(Group AHP) is combined with two different methods of assigning experts' priority to weight indicators in building energy efficiency assessment.One is to assign the experts' priority ... Analytic hierarchy process(Group AHP) is combined with two different methods of assigning experts' priority to weight indicators in building energy efficiency assessment.One is to assign the experts' priority averagely,and the other is to use cluster analysis to assign experts' priority.The results show that,1) Different expert's priority assigns result in great different weights of indicators in building energy efficiency assessment,therefore,the method of assigning experts' priority should be taken into account carefully while weighting indicators of building energy efficiency assessment using Group AHP;2) Three indicators are found to be overwhelmingly important in residential building energy efficiency assessment in the hot summer and cold winter zone in China.They are 'Outdoor & indoor shadow','Heating & air-conditioning facilities' and 'Insulation of envelope';3) The method combining cluster analysis with Group AHP to weight indicator of building energy efficiency assessment has the advantage of finding overwhelming important indicator,whereas,some less important indicators have a tendency to be ignored.A useful reference is provided for building energy conservation including policy revision and energy efficient residential building design. 展开更多
关键词 energy efficiency BUILDING weighting cluster analysis analytic hierarchy process
在线阅读 下载PDF