Rogowski线圈电子式电流互感器实时仿真模型 被引量:10
1
作者 周巍 李学太 +1 位作者 张沛超 高杰 《电力系统保护与控制》 EI CSCD 北大核心 2010年第19期125-129,共5页
基于电力系统实时数字仿真系统(RTDS),研究并建立了Rogowski线圈电子式互感器的数值仿真模型和通信模型。建立了Rogowski线圈等值电路、数字积分器、重采样以及相位补偿等环节的数学模型,利用GTNET,依据IEC61850-9-2标准实现了采样值的... 基于电力系统实时数字仿真系统(RTDS),研究并建立了Rogowski线圈电子式互感器的数值仿真模型和通信模型。建立了Rogowski线圈等值电路、数字积分器、重采样以及相位补偿等环节的数学模型,利用GTNET,依据IEC61850-9-2标准实现了采样值的编码与发送;根据IEC61850标准,利用采样值虚拟端子的概念建立了该电子式互感器的通信模型;开发了系统配置器以完成RTDS与实际保护、测控装置之间的可视化的数据流配置。闭环测试结果表明,提出并实现的电子式电流互感器实时仿真模型有利于提高数字化变电站系统测试的有效性。 展开更多
关键词 电子式互感 合并单元 实时数字仿真 IEC61850 系统配置器
在线阅读 下载PDF
Thermal performance analysis of borehole size effect on geothermal heat exchanger 被引量:2
2
作者 CHOI Hoon-ki YOO Geun-jong +2 位作者 LIM Kyung-bin LEE Sang-hoon LEE Chang-hee 《Journal of Central South University》 SCIE EI CAS 2012年第12期3524-3529,共6页
Thermal performance was the most important factor in the development of borehole heat exchanger utilizing geothermal energy. The thermal performance was affected by many different design parameters, such as configurat... Thermal performance was the most important factor in the development of borehole heat exchanger utilizing geothermal energy. The thermal performance was affected by many different design parameters, such as configuration type and borehole size of geothermal heat exchanger. These eventually determined the operation and cost efficiency of the geothermal heat exchanger system. The main purpose of this work was to assess the thermal performance of geother^nal heat exchanger with variation of borehole sizes and numbers of U-tubes inside a borehole. For this, a thermal response test rig was established with line-source theory. The thermal response test was performed with in-line variable input heat source. Effective thermal conductivity and thermal resistance were obtained from the measured data. From the measurement, the effective thermal conductivity is found to have similar values for two- pair type (4 U-tubes) and three-pair type (6 U-tubes) borehole heat exchanger systems indicating similar heat transfer ability. Meanwhile, the thermal resistance shows lower value for the three-pair type compared to the two-pair type. Measured data based resistance have lower value compared to computed result from design programs. Overall comparison finds better thermal performance for the three-pair type, however, fluctuating temperature variation indicates complex flow behavior inside the borehole and requires further study on flow characteristics. 展开更多
关键词 large size borehole heat exchanger thermal response test effective thermal conductivity thermal resistance BOREHOLE
在线阅读 下载PDF