To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) metho...To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) method based on thermal energy storage to eliminate frost off the outdoor coil surface was developed. Comparative experiments using both the stand reverse cycle defrosting (SRCD) method and the NRCD method were carried out on an experimental ASHP unit with a nominal 2.5 kW heating capacity. The results indicate that during defrosting operation, using the NRCD method improves discharge and suction pressures by 0.24 MPa and 0.19 MPa, respectively, shortens defrosting duration by 60%, and reduces the defrosting energy consumption by 48.1% in the experimental environment, compared with those by the use of SRCD method. Therefore, using the NRCD method can shorten the defrosting duration, improve the indoor thermal comfort, and reduce the defrosting energy consumption in defrosting.展开更多
For acquiring the details in aluminum holding furnace with bottom porous brick purging system,efforts were performed to try to find out the potential optimal operation schemes.By adopting transient analysis scheme and...For acquiring the details in aluminum holding furnace with bottom porous brick purging system,efforts were performed to try to find out the potential optimal operation schemes.By adopting transient analysis scheme and constant boundary temperature,combustion in the furnace was investigated numerically using computational fluid dynamics(CFD).The predicted gas temperature shows good agreement with the measured results,and the predicted energy distribution of the furnace is consistent with that obtained from energy balance experiment,which confirms the reliability of the numerical solution.The results show that as the fuel-air mixture temperature rises up from 300 K to 500 K,the energy utilization of the furnace could increase from 34.55% to 37.14%.However,as the excess air coefficient increases from 1.0 to 1.4,energy utilization drops from 34.55% to 29.56%.Increasing the combustion temperature is the most effective way to improve the energy efficiency of the furnace.High reactant temperature and medium excess air coefficient are recommended for high operation performance,and keeping the furnace jamb sealed well for avoiding leakage has to be emphasized.展开更多
基金Project(50606007) supported by the National Natural Science Foundation of China
文摘To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) method based on thermal energy storage to eliminate frost off the outdoor coil surface was developed. Comparative experiments using both the stand reverse cycle defrosting (SRCD) method and the NRCD method were carried out on an experimental ASHP unit with a nominal 2.5 kW heating capacity. The results indicate that during defrosting operation, using the NRCD method improves discharge and suction pressures by 0.24 MPa and 0.19 MPa, respectively, shortens defrosting duration by 60%, and reduces the defrosting energy consumption by 48.1% in the experimental environment, compared with those by the use of SRCD method. Therefore, using the NRCD method can shorten the defrosting duration, improve the indoor thermal comfort, and reduce the defrosting energy consumption in defrosting.
基金Project(2009GK2009) supported by the Science and Technology Program of Hunan Province,China
文摘For acquiring the details in aluminum holding furnace with bottom porous brick purging system,efforts were performed to try to find out the potential optimal operation schemes.By adopting transient analysis scheme and constant boundary temperature,combustion in the furnace was investigated numerically using computational fluid dynamics(CFD).The predicted gas temperature shows good agreement with the measured results,and the predicted energy distribution of the furnace is consistent with that obtained from energy balance experiment,which confirms the reliability of the numerical solution.The results show that as the fuel-air mixture temperature rises up from 300 K to 500 K,the energy utilization of the furnace could increase from 34.55% to 37.14%.However,as the excess air coefficient increases from 1.0 to 1.4,energy utilization drops from 34.55% to 29.56%.Increasing the combustion temperature is the most effective way to improve the energy efficiency of the furnace.High reactant temperature and medium excess air coefficient are recommended for high operation performance,and keeping the furnace jamb sealed well for avoiding leakage has to be emphasized.