Understanding the steady mechanism of biomass smoldering plays a great role in the utilization of smoldering technology.In this study numerical analysis of steady smoldering of biomass rods was performed.A two-dimensi...Understanding the steady mechanism of biomass smoldering plays a great role in the utilization of smoldering technology.In this study numerical analysis of steady smoldering of biomass rods was performed.A two-dimensional(2D)steady model taking into account both char oxidation and pyrolysis was developed on the basis of a calculated propagation velocity according to empirical correlation.The model was validated against the smoldering experiment of biomass rods under natural conditions,and the maximum error was smaller than 31%.Parameter sensitivity analysis found that propagation velocity decreases significantly while oxidation area and pyrolysis zone increase significantly with the increasing diameter of rod fuel.展开更多
In order to study the effects of wet compression on a transonic compressor,a full 3-D steady numerical simulation was carried out under varying conditions.Different injected water flow rates and droplet diameters were...In order to study the effects of wet compression on a transonic compressor,a full 3-D steady numerical simulation was carried out under varying conditions.Different injected water flow rates and droplet diameters were considered.The effect of wet compression on the shock,separated flow,pressure ratio,and efficiency was investigated.Additionally,the effect of wet compression on the tip clearance when the compressor runs in the near-stall and stall situations was emphasized.Analysis of the results shows that the range of stable operation is extended,and that the pressure ratio and inlet air flow rate are also increased at the near-stall point.In addition,it seems that there is an optimum size of the droplet diameter.展开更多
A method for computing DC steady-state solutions in complex frequency-domain is put forward. It starts with complex frequency-domain transmission line equations, obtains the complex expressions of voltage and current ...A method for computing DC steady-state solutions in complex frequency-domain is put forward. It starts with complex frequency-domain transmission line equations, obtains the complex expressions of voltage and current at zero initial states, and find the DC steady-state solutions of voltage and current by using the fina value theorem of Laplace transform thory. The solutions are discussed with special internal resistances of DC voltage source and loads. A case study demonstrated that the proposed method is applicable to acquiring the DC steady-state voltage waveform and current waveform without first obtaining the analytic solutions.展开更多
文摘Understanding the steady mechanism of biomass smoldering plays a great role in the utilization of smoldering technology.In this study numerical analysis of steady smoldering of biomass rods was performed.A two-dimensional(2D)steady model taking into account both char oxidation and pyrolysis was developed on the basis of a calculated propagation velocity according to empirical correlation.The model was validated against the smoldering experiment of biomass rods under natural conditions,and the maximum error was smaller than 31%.Parameter sensitivity analysis found that propagation velocity decreases significantly while oxidation area and pyrolysis zone increase significantly with the increasing diameter of rod fuel.
基金Supported by the National Natural Science Foundation of China under Grant No.50776021
文摘In order to study the effects of wet compression on a transonic compressor,a full 3-D steady numerical simulation was carried out under varying conditions.Different injected water flow rates and droplet diameters were considered.The effect of wet compression on the shock,separated flow,pressure ratio,and efficiency was investigated.Additionally,the effect of wet compression on the tip clearance when the compressor runs in the near-stall and stall situations was emphasized.Analysis of the results shows that the range of stable operation is extended,and that the pressure ratio and inlet air flow rate are also increased at the near-stall point.In addition,it seems that there is an optimum size of the droplet diameter.
文摘A method for computing DC steady-state solutions in complex frequency-domain is put forward. It starts with complex frequency-domain transmission line equations, obtains the complex expressions of voltage and current at zero initial states, and find the DC steady-state solutions of voltage and current by using the fina value theorem of Laplace transform thory. The solutions are discussed with special internal resistances of DC voltage source and loads. A case study demonstrated that the proposed method is applicable to acquiring the DC steady-state voltage waveform and current waveform without first obtaining the analytic solutions.