A single machine-infinite-bus(SMIB) system including the interline power flow controllers(IPFCs) and the power system stabilizer(PSS) controller is addressed. The linearized system model is considered for investigatin...A single machine-infinite-bus(SMIB) system including the interline power flow controllers(IPFCs) and the power system stabilizer(PSS) controller is addressed. The linearized system model is considered for investigating the interactions among IPFC and PSS controllers. To improve the stability of whole system again different disturbances, a lead-lag controller is considered to produce supplementary signal. The proposed supplementary controller is implemented to improve the damping of the power system low frequency oscillations(LFOs). Imperialist optimization algorithm(ICA) and shuffled frog leaping algorithm(SFLA) are implemented to search for optimal supplementary controllers and PSS parameters. Moreover, singular value decomposition(SVD) method is utilized to select the most effective damping control signal of IPFC lead-lag controllers. To evaluate the system performance, different operating conditions are considered. Reponses of system in five modes including uncoordinated and coordinated modes of IPFC and PSS using ICA and SFLA are studied and compared. Considering the results, response of system without controller shows the highest overshoot and the longest settling time for rotor angel at the different operating conditions. In this mode of system, rotor speed has the highest overshoot. Rotor angel in the system with only PSS includes lower overshoot and oscillation than system without controller. When PSS is only implemented, rotor speed deviation has the longest settling time. Rotor speed deviation in the uncoordinated mode of IPFC and PSS shows lower overshoot than system with only PSS and without controller. It is noticeable that in this mode, rotor angel has higher overshoot than system with only PSS. The superiority of the suggested ICA-based coordinated controllers is obvious compared with SFLA-based coordinated controllers and other system modes. Responses of coordinated PSS and IPFC SFLA-based supplementary controllers include higher peak amplitude and longer settling time compared with coordinated IPFC and PSS ICA-based controllers. This comparison shows that overshoots, undershoots and the settling times are reduced considerably in coordinated mode of IPFC based controller and PSS using ICA. Analysis of the system performance shows that the proposed method has excellent response to different faults in power system.展开更多
For the purpose of improving efficiency and realizing start–stop function, an electric oil pump(EOP) is integrated into an 8-speed automatic transmission(AT). A mathematical model is built to calculate the transmissi...For the purpose of improving efficiency and realizing start–stop function, an electric oil pump(EOP) is integrated into an 8-speed automatic transmission(AT). A mathematical model is built to calculate the transmission power loss and the hydraulic system leakage. Based on this model, a flow-based control strategy is developed for EOP to satisfy the system flow requirement. This control strategy is verified through the forward driving simulation. The results indicate that there is a best combination for the size of mechanical oil pump(MOP) and EOP in terms of minimum energy consumption. In order to get a quick and smooth starting process, control strategies of the EOP and the on-coming clutch are proposed. The test environment on a prototype vehicle is built to verify the feasibility of the integrated EOP and its control strategies. The results show that the selected EOP can satisfy the flow requirement and a quick and smooth starting performance is achieved in the start–stop function. This research has a high value for the forward design of EOP in automatic transmissions with respect to efficiency improvement and start–stop function.展开更多
For the conventional single-ended eFuse cell, sensing failures can occur due to a variation of a post-program eFuse resistance during the data retention time and a relatively high program resistance of several kilo oh...For the conventional single-ended eFuse cell, sensing failures can occur due to a variation of a post-program eFuse resistance during the data retention time and a relatively high program resistance of several kilo ohms. A differential paired eFuse cell is designed which is about half the size smaller in sensing resistance of a programmed eFuse link than the conventional single-ended eFuse cell. Also, a sensing circuit of sense amplifier is proposed, based on D flip-flop structure to implement a simple sensing circuit. Furthermore, a sensing margin test circuit is proposed with variable pull-up loads out of consideration for resistance variation of a programmed eFuse. When an 8 bit eFuse OTP IP is designed with 0.18 ~tm standard CMOS logic of TSMC, the layout dimensions are 229.04 μm ×100.15μm. All the chips function successfully when 20 test chips are tested with a program voltage of 4.2 V.展开更多
A mathematical approach was proposed to investigate the impact of high penetration of large-scale photovoltaic park(LPP) on small-signal stability of a power network and design of hybrid controller for these units.A s...A mathematical approach was proposed to investigate the impact of high penetration of large-scale photovoltaic park(LPP) on small-signal stability of a power network and design of hybrid controller for these units.A systematic procedure was performed to obtain the complete model of a multi-machine power network including LPP.For damping of oscillations focusing on inter-area oscillatory modes,a hybrid controller for LPP was proposed.The performance of the suggested controller was tested using a 16-machine 5-area network.The results indicate that the proposed hybrid controller for LPP provides sufficient damping to the low-frequency modes of power system for a wide range of operating conditions.The method presented in this work effectively indentifies the impact of increased PV penetration and its controller on dynamic performance of multi-machine power network containing LPP.Simulation results demonstrate that the model presented can be used in designing of essential controllers for LPP.展开更多
The variance-dependent Goldstein radar interferogram filter takes into account the information of both interferometric coherence and multilook factors,and can produce very consistent results for interferograms generat...The variance-dependent Goldstein radar interferogram filter takes into account the information of both interferometric coherence and multilook factors,and can produce very consistent results for interferograms generated under a wide variety of multilook factors and with very different noise level.However,the filter is a bit complicated and its application is still very limited.We present the designing and implementation of the variance-dependent Goldstein radar interferogram filtering,emphasizing on the logic flow,the generation of look-up table,the determination of filtering parameter,and the handling of edge information loss.Experiments with real interferograms are provided to demonstrate the applications of the designed filtering.Comparisons with the result of the coherence-dependent Goldstein filter show that improvements from 18.4% to 36.9% are achieved when the variance-dependent filter is used,and the noisier the interferogram,the greater the improvement.展开更多
文摘A single machine-infinite-bus(SMIB) system including the interline power flow controllers(IPFCs) and the power system stabilizer(PSS) controller is addressed. The linearized system model is considered for investigating the interactions among IPFC and PSS controllers. To improve the stability of whole system again different disturbances, a lead-lag controller is considered to produce supplementary signal. The proposed supplementary controller is implemented to improve the damping of the power system low frequency oscillations(LFOs). Imperialist optimization algorithm(ICA) and shuffled frog leaping algorithm(SFLA) are implemented to search for optimal supplementary controllers and PSS parameters. Moreover, singular value decomposition(SVD) method is utilized to select the most effective damping control signal of IPFC lead-lag controllers. To evaluate the system performance, different operating conditions are considered. Reponses of system in five modes including uncoordinated and coordinated modes of IPFC and PSS using ICA and SFLA are studied and compared. Considering the results, response of system without controller shows the highest overshoot and the longest settling time for rotor angel at the different operating conditions. In this mode of system, rotor speed has the highest overshoot. Rotor angel in the system with only PSS includes lower overshoot and oscillation than system without controller. When PSS is only implemented, rotor speed deviation has the longest settling time. Rotor speed deviation in the uncoordinated mode of IPFC and PSS shows lower overshoot than system with only PSS and without controller. It is noticeable that in this mode, rotor angel has higher overshoot than system with only PSS. The superiority of the suggested ICA-based coordinated controllers is obvious compared with SFLA-based coordinated controllers and other system modes. Responses of coordinated PSS and IPFC SFLA-based supplementary controllers include higher peak amplitude and longer settling time compared with coordinated IPFC and PSS ICA-based controllers. This comparison shows that overshoots, undershoots and the settling times are reduced considerably in coordinated mode of IPFC based controller and PSS using ICA. Analysis of the system performance shows that the proposed method has excellent response to different faults in power system.
基金Project(51405010)supported by the National Natural Science Foundation of ChinaProject(2011BAG09B00)supported by the National Science and Technology Support Program of China
文摘For the purpose of improving efficiency and realizing start–stop function, an electric oil pump(EOP) is integrated into an 8-speed automatic transmission(AT). A mathematical model is built to calculate the transmission power loss and the hydraulic system leakage. Based on this model, a flow-based control strategy is developed for EOP to satisfy the system flow requirement. This control strategy is verified through the forward driving simulation. The results indicate that there is a best combination for the size of mechanical oil pump(MOP) and EOP in terms of minimum energy consumption. In order to get a quick and smooth starting process, control strategies of the EOP and the on-coming clutch are proposed. The test environment on a prototype vehicle is built to verify the feasibility of the integrated EOP and its control strategies. The results show that the selected EOP can satisfy the flow requirement and a quick and smooth starting performance is achieved in the start–stop function. This research has a high value for the forward design of EOP in automatic transmissions with respect to efficiency improvement and start–stop function.
文摘For the conventional single-ended eFuse cell, sensing failures can occur due to a variation of a post-program eFuse resistance during the data retention time and a relatively high program resistance of several kilo ohms. A differential paired eFuse cell is designed which is about half the size smaller in sensing resistance of a programmed eFuse link than the conventional single-ended eFuse cell. Also, a sensing circuit of sense amplifier is proposed, based on D flip-flop structure to implement a simple sensing circuit. Furthermore, a sensing margin test circuit is proposed with variable pull-up loads out of consideration for resistance variation of a programmed eFuse. When an 8 bit eFuse OTP IP is designed with 0.18 ~tm standard CMOS logic of TSMC, the layout dimensions are 229.04 μm ×100.15μm. All the chips function successfully when 20 test chips are tested with a program voltage of 4.2 V.
文摘A mathematical approach was proposed to investigate the impact of high penetration of large-scale photovoltaic park(LPP) on small-signal stability of a power network and design of hybrid controller for these units.A systematic procedure was performed to obtain the complete model of a multi-machine power network including LPP.For damping of oscillations focusing on inter-area oscillatory modes,a hybrid controller for LPP was proposed.The performance of the suggested controller was tested using a 16-machine 5-area network.The results indicate that the proposed hybrid controller for LPP provides sufficient damping to the low-frequency modes of power system for a wide range of operating conditions.The method presented in this work effectively indentifies the impact of increased PV penetration and its controller on dynamic performance of multi-machine power network containing LPP.Simulation results demonstrate that the model presented can be used in designing of essential controllers for LPP.
基金Project(2013CB733303)supported by the National Basic Research Program of ChinaProjects(41222027,11103068,41104003)supported by the National Natural Science Foundation of China+3 种基金Project(13JJ1006)supported by Hunan Provincial Natural Science Foundation,ChinaProject(TXCL-KF2013-002)supported by the Key Laboratory of Videometric and Vision Navigation of Hunan Province,ChinaProject(SKLGED2013-2-1-E)supported by the State Key Laboratory of Geodesy and Earth’s Dynamics,ChinaProject(K201208)supported by the Key Laboratory of Earth Observation Technique of National Administration of Surveying,Mapping and Geoinformation,China
文摘The variance-dependent Goldstein radar interferogram filter takes into account the information of both interferometric coherence and multilook factors,and can produce very consistent results for interferograms generated under a wide variety of multilook factors and with very different noise level.However,the filter is a bit complicated and its application is still very limited.We present the designing and implementation of the variance-dependent Goldstein radar interferogram filtering,emphasizing on the logic flow,the generation of look-up table,the determination of filtering parameter,and the handling of edge information loss.Experiments with real interferograms are provided to demonstrate the applications of the designed filtering.Comparisons with the result of the coherence-dependent Goldstein filter show that improvements from 18.4% to 36.9% are achieved when the variance-dependent filter is used,and the noisier the interferogram,the greater the improvement.