Predicting the life of Ni-Cd battery for electric multiple units(EMU)can not only improve the safety and reliability of battery,but also reduce the operating costs of EMU.For this reason,a life prediction method based...Predicting the life of Ni-Cd battery for electric multiple units(EMU)can not only improve the safety and reliability of battery,but also reduce the operating costs of EMU.For this reason,a life prediction method based on linear Wiener process is proposed,which is suitable for both monotonic and non-monotonic degraded systems with accurate results.Firstly,a unary linear Wiener degradation model is established,and the parameters of the model are estimated by using the expectation-maximization algorithm(EM).With the established model,the remaining useful life(RUL)of Ni Cd battery and its distribution are obtained.Then based on the unary Wiener process degradation model,the correlation between capacity and energy is analyzed through Copula function to build a binary linear Wiener degradation model,where its parameters are estimated using Markov Chain Monte Carlo(MCMC)method.Finally,according to the binary Wiener process model,the battery RUL and its distribution are acquired.The experimental results show that the binary linear Wiener degradation model based on capacity and energy possesses higher accuracy than the unary linear wiener process degradation model.展开更多
Real time remaining useful life(RUL) prediction based on condition monitoring is an essential part in condition based maintenance(CBM). In the current methods about the real time RUL prediction of the nonlinear degrad...Real time remaining useful life(RUL) prediction based on condition monitoring is an essential part in condition based maintenance(CBM). In the current methods about the real time RUL prediction of the nonlinear degradation process, the measurement error is not considered and forecasting uncertainty is large. Therefore, an approximate analytical RUL distribution in a closed-form of a nonlinear Wiener based degradation process with measurement errors was proposed. The maximum likelihood estimation approach was used to estimate the unknown fixed parameters in the proposed model. When the newly observed data are available, the random parameter is updated by the Bayesian method to make the estimation adapt to the item's individual characteristic and reduce the uncertainty of the estimation. The simulation results show that considering measurement errors in the degradation process can significantly improve the accuracy of real time RUL prediction.展开更多
Chloride-induced corrosion of the reinforcement is considered as one of the major mechanisms resulting in the reduction of structural resistance of reinforced concrete structural elements located in marine and other a...Chloride-induced corrosion of the reinforcement is considered as one of the major mechanisms resulting in the reduction of structural resistance of reinforced concrete structural elements located in marine and other aggressive environments. A study of reinforced concrete structures located at the Fangcheng dock in the Beibu Gulf port, China, was present. The result from field survey indicates that the concrete cover depth and chloride diffusion coefficient fit best normal distribution and lognormal distribution, respectively. The service life of structure is about 55 a, while initiation time is 45 a. Sensitivity analysis indicates that the most influential factor of the structure service life prediction is concrete cover, followed by diffusion coefficient, diffusion decay index, critical chloride concentration, surface chloride concentration, current density and localized pitting corrosion. Finally, the effects of diffusion decay index and critical chloride concentration on structure service life prediction are discussed.展开更多
基金Project(2017 YFB 1200801-12)supported by the National Natural Science Foundation of China。
文摘Predicting the life of Ni-Cd battery for electric multiple units(EMU)can not only improve the safety and reliability of battery,but also reduce the operating costs of EMU.For this reason,a life prediction method based on linear Wiener process is proposed,which is suitable for both monotonic and non-monotonic degraded systems with accurate results.Firstly,a unary linear Wiener degradation model is established,and the parameters of the model are estimated by using the expectation-maximization algorithm(EM).With the established model,the remaining useful life(RUL)of Ni Cd battery and its distribution are obtained.Then based on the unary Wiener process degradation model,the correlation between capacity and energy is analyzed through Copula function to build a binary linear Wiener degradation model,where its parameters are estimated using Markov Chain Monte Carlo(MCMC)method.Finally,according to the binary Wiener process model,the battery RUL and its distribution are acquired.The experimental results show that the binary linear Wiener degradation model based on capacity and energy possesses higher accuracy than the unary linear wiener process degradation model.
基金Projects(51475462,61374138,61370031)supported by the National Natural Science Foundation of China
文摘Real time remaining useful life(RUL) prediction based on condition monitoring is an essential part in condition based maintenance(CBM). In the current methods about the real time RUL prediction of the nonlinear degradation process, the measurement error is not considered and forecasting uncertainty is large. Therefore, an approximate analytical RUL distribution in a closed-form of a nonlinear Wiener based degradation process with measurement errors was proposed. The maximum likelihood estimation approach was used to estimate the unknown fixed parameters in the proposed model. When the newly observed data are available, the random parameter is updated by the Bayesian method to make the estimation adapt to the item's individual characteristic and reduce the uncertainty of the estimation. The simulation results show that considering measurement errors in the degradation process can significantly improve the accuracy of real time RUL prediction.
基金Project(41274012) supported by the National Natural Science Foundation of China
文摘Chloride-induced corrosion of the reinforcement is considered as one of the major mechanisms resulting in the reduction of structural resistance of reinforced concrete structural elements located in marine and other aggressive environments. A study of reinforced concrete structures located at the Fangcheng dock in the Beibu Gulf port, China, was present. The result from field survey indicates that the concrete cover depth and chloride diffusion coefficient fit best normal distribution and lognormal distribution, respectively. The service life of structure is about 55 a, while initiation time is 45 a. Sensitivity analysis indicates that the most influential factor of the structure service life prediction is concrete cover, followed by diffusion coefficient, diffusion decay index, critical chloride concentration, surface chloride concentration, current density and localized pitting corrosion. Finally, the effects of diffusion decay index and critical chloride concentration on structure service life prediction are discussed.