The Microcystis aeruginosa(MA) was immobilized on sodium alginate and used as biosorbent for removal of Cd(Ⅱ) ions from aqueous solution.The biosorption process is pH dependent,and the optimum biosorption was observe...The Microcystis aeruginosa(MA) was immobilized on sodium alginate and used as biosorbent for removal of Cd(Ⅱ) ions from aqueous solution.The biosorption process is pH dependent,and the optimum biosorption was observed at pH 6.0 with the biosorption capacity of 98.38 mg/g.Among Langmuir,Freundlich and Temkin isotherm models,the Freundlich and the Temkin isotherm fit well with the experimental data.Cd(Ⅱ) ions biosorption follows the pseudo-second-order kinetic model.The rate controlling mechanism study reveals that film diffusion is the rate-limiting step and intraparticle diffusion is also involved in biosorption.Thermodynamic parameters,such as Gibbs free energy(ΔG°),the enthalpy(ΔH°) and entropy(ΔS°) were calculated,and revealed that the biosorption process is spontaneous,exothermic and random.Furthermore,the immobilized MA can be regenerated using 0.1 mol/L HCl solutions.展开更多
Based on theory of variable-mass system thermodynamics, the dynamic mathematic models of each component of the horizontal steam-launch system were established, and by the numerical simulation of the system launching p...Based on theory of variable-mass system thermodynamics, the dynamic mathematic models of each component of the horizontal steam-launch system were established, and by the numerical simulation of the system launching process, the thermodynamics and kinetics characteristics of the system with three valves of different flow characteristics were got. The simulation results show that the values of the peak-to-average ratios of dimensionless acceleration with the equal percentage valve, the linear valve and the quick opening valve are 1.355, 1.614 and 1.722, respectively, and the final values of the dimensionless velocities are 0.843, 0.957 and 1.0, respectively. In conclusion, the value of the dimensionless velocity with the equal percentage valve doesn't reach the set value of 0.90 when the dimensionless displacement is 0.82, while the system with the linear valve can meet the launching requirement, as well as the fluctuation range of dimensionless acceleration is less than that of the quick opening valve. Therefore, the system with the linear valve has the best performance among the three kinds of valves.展开更多
基金Project(41271332) supported by the National Natural Science Foundation of ChinaProject(11JJ2031) supported by the Natural Science Foundation of Hunan Province,China+1 种基金Project(2012SK2021) supported by the Science and Technology Planning Program of Hunan Province,ChinaProject(CX2012B138) supported by the Hunan Provincial Innovation Foundation for Postgraduate,China
文摘The Microcystis aeruginosa(MA) was immobilized on sodium alginate and used as biosorbent for removal of Cd(Ⅱ) ions from aqueous solution.The biosorption process is pH dependent,and the optimum biosorption was observed at pH 6.0 with the biosorption capacity of 98.38 mg/g.Among Langmuir,Freundlich and Temkin isotherm models,the Freundlich and the Temkin isotherm fit well with the experimental data.Cd(Ⅱ) ions biosorption follows the pseudo-second-order kinetic model.The rate controlling mechanism study reveals that film diffusion is the rate-limiting step and intraparticle diffusion is also involved in biosorption.Thermodynamic parameters,such as Gibbs free energy(ΔG°),the enthalpy(ΔH°) and entropy(ΔS°) were calculated,and revealed that the biosorption process is spontaneous,exothermic and random.Furthermore,the immobilized MA can be regenerated using 0.1 mol/L HCl solutions.
基金Project(20080431380)supported by the National Postdoctoral Science Foundation,China
文摘Based on theory of variable-mass system thermodynamics, the dynamic mathematic models of each component of the horizontal steam-launch system were established, and by the numerical simulation of the system launching process, the thermodynamics and kinetics characteristics of the system with three valves of different flow characteristics were got. The simulation results show that the values of the peak-to-average ratios of dimensionless acceleration with the equal percentage valve, the linear valve and the quick opening valve are 1.355, 1.614 and 1.722, respectively, and the final values of the dimensionless velocities are 0.843, 0.957 and 1.0, respectively. In conclusion, the value of the dimensionless velocity with the equal percentage valve doesn't reach the set value of 0.90 when the dimensionless displacement is 0.82, while the system with the linear valve can meet the launching requirement, as well as the fluctuation range of dimensionless acceleration is less than that of the quick opening valve. Therefore, the system with the linear valve has the best performance among the three kinds of valves.