期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
几种复合减水剂的分散效应与作用机理 被引量:8
1
作者 刘才林 任先艳 +1 位作者 杨海君 杨军校 《建筑材料学报》 EI CAS CSCD 北大核心 2011年第1期111-115,共5页
采用合适比例的聚羧酸系高效减水剂复合改性脂肪族系、三聚氰胺系和萘系高效减水剂,制备了3种复合减水剂,研究了它们对水泥净浆性能及混凝土性能的影响;通过Zeta电位测定和X射线光电子能谱(XPS)分析研究了复合减水剂的分散作用机理.结... 采用合适比例的聚羧酸系高效减水剂复合改性脂肪族系、三聚氰胺系和萘系高效减水剂,制备了3种复合减水剂,研究了它们对水泥净浆性能及混凝土性能的影响;通过Zeta电位测定和X射线光电子能谱(XPS)分析研究了复合减水剂的分散作用机理.结果表明:脂肪族系-聚羧酸系复合减水剂是静电斥力起了主导作用,三聚氰胺系-聚羧酸系复合减水剂和萘系-聚羧酸系复合减水剂是聚羧酸系减水剂的空间位阻效应起了主导作用. 展开更多
关键词 混凝土高效减水剂 ZETA电位 分散作用机理
在线阅读 下载PDF
改性木素磺酸盐泵送剂GCL1-3的制备及性能研究 被引量:5
2
作者 庞煜霞 邱学青 +1 位作者 欧阳新平 杨东杰 《精细化工》 EI CAS CSCD 北大核心 2001年第10期595-598,共4页
通过研究缓凝高效减水剂GCL1与保水剂、引气剂的配伍性能 ,研制了混凝土泵送剂GCL1- 3。GCL1与保水剂HEC、引气剂复配时 ,改善了水泥净浆的保水性能 ,提高了硬化水泥的早期及后期抗压强度。实验测试了GCL1- 3的水泥净浆流动度、减水率... 通过研究缓凝高效减水剂GCL1与保水剂、引气剂的配伍性能 ,研制了混凝土泵送剂GCL1- 3。GCL1与保水剂HEC、引气剂复配时 ,改善了水泥净浆的保水性能 ,提高了硬化水泥的早期及后期抗压强度。实验测试了GCL1- 3的水泥净浆流动度、减水率、流动度损失和抗压强度等性能。结果表明 ,当w (水 )∶w(水泥 ) =0 4∶1 0 ,w (GCL1- 3) =0 .5 %时 ,水泥净浆流动度可达2 30mm ,减水率达 18% ,且无离析现象 ;2h内流动度损失仅为 2 4% ,而掺FDN的净浆已经失去流动性 ;w(GCL1- 3) =0 .5 %时 ,水泥净浆硬化 3d、7d、2 8d的抗压强度比分别达 146 %、15 8%与148% 。 展开更多
关键词 改性木钙 泵送剂 滤水 改性木素磺酸盐 混凝土缓凝高效减水剂 GCL1-3 制备
在线阅读 下载PDF
Statistical modelling for effect of mix-parameters on properties of high-flowing sand-concrete 被引量:7
3
作者 T.BOUZIANI A.BENMOUNAH M.BDRINA 《Journal of Central South University》 SCIE EI CAS 2012年第10期2966-2975,共10页
The high-flowing sand-concrete (HFSC) containing natural sands as aggregate was carried out. The high fluidity and stability of HFSC can be achieved by tailoring the mix design parameters, such as fine to coarse san... The high-flowing sand-concrete (HFSC) containing natural sands as aggregate was carried out. The high fluidity and stability of HFSC can be achieved by tailoring the mix design parameters, such as fine to coarse sand ratio, dosage of additions, water to binder ratio and dosage of admixtures. Mini-cone slump test, v-fl.mnel time test and viscosity model parameters were used to characterize the behaviour of HFSC in fresh state. The mechanical compressive strength in 28 d was also determined. A factorial design approach was used to establish models highlighting the effect of each mix-parameter on measured properties of HFSC. The derived models are valid for mixtures made with 0 to 0.3 of dune sand to total sand ratio, 82 to 418 kg/m3 of marble powder, 0.42 to 0.46 of water/binder ratio and 1.3% to 1.9% of superplasticizer high water-reducer. The results show that the derived models constitute very efficient means for understanding the influence of key mix-parameters on HFSC properties and are useful in selecting the optimum mix proportions, by simulating their impact on fluidity, stability and compressive strength. 展开更多
关键词 high-flowing sand-concrete factorial design FLUIDITY VISCOSITY mix-design parameters
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部