Aim To fuse the fluorescence image and transmission image of a cell into a single image containing more information than any of the individual image. Methods Image fusion technology was applied to biological cell imag...Aim To fuse the fluorescence image and transmission image of a cell into a single image containing more information than any of the individual image. Methods Image fusion technology was applied to biological cell imaging processing. It could match the images and improve the confidence and spatial resolution of the images. Using two algorithms, double thresholds algorithm and denoising algorithm based on wavelet transform,the fluorescence image and transmission image of a Cell were merged into a composite image. Results and Conclusion The position of fluorescence and the structure of cell can be displyed in the composite image. The signal-to-noise ratio of the exultant image is improved to a large extent. The algorithms are not only useful to investigate the fluorescence and transmission images, but also suitable to observing two or more fluoascent label proes in a single cell.展开更多
Full duplex radio increases the frequency efficiency but its performance is limited by the self-interference (SI). We first analyze the multiple noises in the full duplex radio system and model such noises as an α ...Full duplex radio increases the frequency efficiency but its performance is limited by the self-interference (SI). We first analyze the multiple noises in the full duplex radio system and model such noises as an α - stable distribution. Then we formulate a novel non-Gaussian SI problem. Under the maximum correntropy criterion (MCC), a robust digital non-linear self-interference cancellation algorithm is proposed for the SI channel estimation. A gradient descent based algorithm is derived to search the optimal solution. Simulation results show that the proposed algorithm can achieve a smaller estimation error and a higher pseudo signal to interference plus noise ratio (PSINR) than the well-known least mean square (LMS) algorithm and least square (LS) algorithm.展开更多
The reconstruction of background noise from an error signal of an adaptive filter is a key issue for developing Variable Step-Size Normalized Least Mean Square (VSS-NLMS) algorithm in the context of Echo Cancellation ...The reconstruction of background noise from an error signal of an adaptive filter is a key issue for developing Variable Step-Size Normalized Least Mean Square (VSS-NLMS) algorithm in the context of Echo Cancellation (EC). The core parameter in this algorithm is the Background Noise Power (BNP); in the estimation of BNP, the power difference between the desired signal and the filter output, statistically equaling to the error signal power, has been widely used in a rough manner. In this study, a precise BNP estimate is implemented by multiplying the rough estimate with a corrective factor, taking into consideration the fact that the error signal consists of background noise and misalignment noise. This corrective factor is obtained by subtracting half of the latest VSS value from 1 after analyzing the ratio of BNP to the misalignment noise. Based on the precise BNP estimate, the PVSS-NLMS algorithm suitable for the EC system is eventually proposed. In practice, the proposed algorithm exhibits a significant advantage of easier controllability application, as prior knowledge of the EC environment can be neglected. The simulation results support the preciseness of the BNP estimation and the effectiveness of the proposed algorithm.展开更多
文摘Aim To fuse the fluorescence image and transmission image of a cell into a single image containing more information than any of the individual image. Methods Image fusion technology was applied to biological cell imaging processing. It could match the images and improve the confidence and spatial resolution of the images. Using two algorithms, double thresholds algorithm and denoising algorithm based on wavelet transform,the fluorescence image and transmission image of a Cell were merged into a composite image. Results and Conclusion The position of fluorescence and the structure of cell can be displyed in the composite image. The signal-to-noise ratio of the exultant image is improved to a large extent. The algorithms are not only useful to investigate the fluorescence and transmission images, but also suitable to observing two or more fluoascent label proes in a single cell.
基金supported by the National Natural Science Foundation of China under Grants 61372092"863" Program under Grants 2014AA01A701
文摘Full duplex radio increases the frequency efficiency but its performance is limited by the self-interference (SI). We first analyze the multiple noises in the full duplex radio system and model such noises as an α - stable distribution. Then we formulate a novel non-Gaussian SI problem. Under the maximum correntropy criterion (MCC), a robust digital non-linear self-interference cancellation algorithm is proposed for the SI channel estimation. A gradient descent based algorithm is derived to search the optimal solution. Simulation results show that the proposed algorithm can achieve a smaller estimation error and a higher pseudo signal to interference plus noise ratio (PSINR) than the well-known least mean square (LMS) algorithm and least square (LS) algorithm.
文摘The reconstruction of background noise from an error signal of an adaptive filter is a key issue for developing Variable Step-Size Normalized Least Mean Square (VSS-NLMS) algorithm in the context of Echo Cancellation (EC). The core parameter in this algorithm is the Background Noise Power (BNP); in the estimation of BNP, the power difference between the desired signal and the filter output, statistically equaling to the error signal power, has been widely used in a rough manner. In this study, a precise BNP estimate is implemented by multiplying the rough estimate with a corrective factor, taking into consideration the fact that the error signal consists of background noise and misalignment noise. This corrective factor is obtained by subtracting half of the latest VSS value from 1 after analyzing the ratio of BNP to the misalignment noise. Based on the precise BNP estimate, the PVSS-NLMS algorithm suitable for the EC system is eventually proposed. In practice, the proposed algorithm exhibits a significant advantage of easier controllability application, as prior knowledge of the EC environment can be neglected. The simulation results support the preciseness of the BNP estimation and the effectiveness of the proposed algorithm.