Froth flotation is used widely for upgrading raw phosphate.The flotation recovery of coarse phosphate(-1.18+0.425 mm) is much lower than that achieved on the-0.425+0.15 mm size fraction.Enhanced recovery of coarse pho...Froth flotation is used widely for upgrading raw phosphate.The flotation recovery of coarse phosphate(-1.18+0.425 mm) is much lower than that achieved on the-0.425+0.15 mm size fraction.Enhanced recovery of coarse phosphate particles is of great economic and environmental importance for phosphate industry.In this investigation,four different phosphate samples were aquired,characterized and tested in a specially designed laboratory-scale flotation column.Significant recovery improvement of coarse phosphate flotation was achieved using cavitation-generated nanobubble though its effects differ among the four testing phosphate samples.The laboratory-scale flotation column test results indicate that nanobubble increased P_2O_5 recovery by up to 10%~30%for a given Acid Insoluble(A.I.) rejection,depending on the characteristic of phosphate samples.The improvement effect of nanobubble on the hard-to-float particles was more significant than that on easy-to-float particles,especially at lower collector dosages.Nanobubbles reduced the collector dosage by 1/3 to 1/2.Nanobubbles almost doubled the coarse phosphate flotation rate constant and increased the flotation selectivity index by up to 25%.展开更多
This study was performed in two phases of work.In the first stage,four conventional first-order flotation kinetics models were fitted to the measured recoveries data and the best model were selected.In the second stag...This study was performed in two phases of work.In the first stage,four conventional first-order flotation kinetics models were fitted to the measured recoveries data and the best model were selected.In the second stage,influence of pH,solid concentration,water chemistry and the amount of collector dosage were investigated on kinetics parameters including flotation rate constant and ultimate recovery.The results indicated that that perfectly mixed reactor model and Kelsall model gave the best and the weakest fit to the experimental data,respectively.It was observed that flotation rate constant and ultimate recovery were strongly affected by chemical factors investigated especially water quality.The flotation rate constant decreased with increasing the solids content,while ultimate recovery increased to certain value and thereafter reduced.It was also found that the most values of flotation rate constant and ultimate recovery obtained in dosage of collector are 30 and 40 g/t,respectively.展开更多
基金the Florida Institute of Phosphate Research(FIPR),The Center for Advanced Separation Technologies(CAST) and the National Natural Science Foundation of China (Nos.50921002 and 90510002) for the financial supportCF Industry Inc and Mosaic Company for supplying specimens and ArrMaz Custom Chemicals Inc.for providing chemicals employed in this study.
文摘Froth flotation is used widely for upgrading raw phosphate.The flotation recovery of coarse phosphate(-1.18+0.425 mm) is much lower than that achieved on the-0.425+0.15 mm size fraction.Enhanced recovery of coarse phosphate particles is of great economic and environmental importance for phosphate industry.In this investigation,four different phosphate samples were aquired,characterized and tested in a specially designed laboratory-scale flotation column.Significant recovery improvement of coarse phosphate flotation was achieved using cavitation-generated nanobubble though its effects differ among the four testing phosphate samples.The laboratory-scale flotation column test results indicate that nanobubble increased P_2O_5 recovery by up to 10%~30%for a given Acid Insoluble(A.I.) rejection,depending on the characteristic of phosphate samples.The improvement effect of nanobubble on the hard-to-float particles was more significant than that on easy-to-float particles,especially at lower collector dosages.Nanobubbles reduced the collector dosage by 1/3 to 1/2.Nanobubbles almost doubled the coarse phosphate flotation rate constant and increased the flotation selectivity index by up to 25%.
文摘This study was performed in two phases of work.In the first stage,four conventional first-order flotation kinetics models were fitted to the measured recoveries data and the best model were selected.In the second stage,influence of pH,solid concentration,water chemistry and the amount of collector dosage were investigated on kinetics parameters including flotation rate constant and ultimate recovery.The results indicated that that perfectly mixed reactor model and Kelsall model gave the best and the weakest fit to the experimental data,respectively.It was observed that flotation rate constant and ultimate recovery were strongly affected by chemical factors investigated especially water quality.The flotation rate constant decreased with increasing the solids content,while ultimate recovery increased to certain value and thereafter reduced.It was also found that the most values of flotation rate constant and ultimate recovery obtained in dosage of collector are 30 and 40 g/t,respectively.