Ventilation systems are critical for improving the cabin environment in high-speed trains,and their interest has increased significantly.However,whether air supply non-verticality deteriorates the cabin air environmen...Ventilation systems are critical for improving the cabin environment in high-speed trains,and their interest has increased significantly.However,whether air supply non-verticality deteriorates the cabin air environment,and the flow mechanism behind it and the degree of deterioration are not known.This study first analyzes the interaction between deflection angle and cabin flow field characteristics and ventilation performance.The results revealed that the interior temperature and pollutant concentration decreased slightly with increasing deflection angle,but resulted in significant deterioration of thermal comfort and air quality.This is evidenced by an increase in both draught rate and non-uniformity coefficient,an increase in the number of measurement points that do not satisfy the micro-wind speed and temperature difference requirements by about 5% and 15%,respectively,and an increase in longitudinal penetration of pollutants by a factor of about 5 and the appearance of locking regions at the ends of cabin.The results also show that changing the deflection pattern only affects the region of deterioration and does not essentially improve this deterioration.This study can provide reference and help for the ventilation design of high-speed trains.展开更多
The reverse magnetohydrodynamic(MHD)energy bypass technology is a promising energy redis⁃tribution technology in the scramjet system,in augmented with a power generation equipment to supply the neces⁃sary long-distanc...The reverse magnetohydrodynamic(MHD)energy bypass technology is a promising energy redis⁃tribution technology in the scramjet system,in augmented with a power generation equipment to supply the neces⁃sary long-distance flight airframe power.In this paper,a computational model of the scramjet magnetohydrody⁃namic channel is developed and verified by using the commercial software Fluent.It is found that when the mag⁃netic induction intensity is 1,2,3,4 T,the power generation efficiency is 22.5%,22.3%,22.0%,21.5%,and decreases with the increase of the magnetic induction intensity,and the enthalpy extraction rate is 0.026%,0.1%,0.21%,0.34%,and increases with the increase of the magnetic induction intensity.The deceleration ef⁃fect of electromagnetic action on the airflow in the power channel increases with the increase of magnetic induc⁃tion intensity.The stronger the magnetic field intensity,the more obvious the decreasing effect of fluid Mach num⁃ber in the channel.The power generation efficiency decreases as the magnetic induction intensity increases and the enthalpy extraction rate is reversed.As the local currents gathering at inlet and outlet of the power generation area,total temperature and enthalpy along the flow direction do not vary linearly,and there are maximum and minimum values at inlet and outlet.Increasing the number of electrodes can effectively regulate the percentage of Joule heat dissipation,which can improve the power generation efficiency.展开更多
In order to control the dust pollution produced by air leg rock drill in the trolley area during the excavation of long-distance single ended tunnel,the full-scale physical model of working face was established by usi...In order to control the dust pollution produced by air leg rock drill in the trolley area during the excavation of long-distance single ended tunnel,the full-scale physical model of working face was established by using FLUENT software,and the numerical simulation analysis of tunnel drilling ventilation and dust removal parameters was carried out.The results show that it is difficult to control the dust pollution of the face by conventional ventilation,and the drilling dust is distributed in the range of 10 m from the face;after the introduction of the long pressure and short suction ventilation scheme,when the ratio of compressed air volume to exhaust air volume is 0.72,the height of the pressure fan is 2.5 m,the distance between the pressure fan and the palm face is 20 m,and the exhaust fan is 12 m away from the palm,the dust concentration control efficiency of the working face is increased by about 60%.Therefore,in the similar long-distance single head tunnel construction,it is appropriate to adopt the dust removal method of long-distance short suction and exhaust fan to ensure the working environment.展开更多
A numerical study is carried out on particle deposition in ducts with either convex or concave wall cavity.Results show that,if compared with smooth duct,particle deposition velocitiesVd^+increase greatly in ducts wit...A numerical study is carried out on particle deposition in ducts with either convex or concave wall cavity.Results show that,if compared with smooth duct,particle deposition velocitiesVd^+increase greatly in ducts with wall cavities.More specifically,forτ+<1,Vd^+increase by about 2–4 orders of magnitude in the cases with the convex and concave wall cavities;forτ+>1,Vd^+grows relatively slower.Enhancement of particle deposition with wall cavities is caused by the following mechanisms,i.e.,interception by the wall cavities,expanded deposition area,and the enhanced flow turbulence.In general,addition of wall cavities is contributive for particle deposition,so it provides an efficient approach to remove particles,especially with small size,e.g.,PM2.5.Moreover,the convex wall cavity leads to a larger increment ofVd^+than the concave wall cavity.However,taking pressure loss into account,thoughVd^+is relatively lower,duct with the concave wall cavity is more efficient than that with the convex wall cavity.展开更多
The wall surface roughness renders a significant impact on ventilation of roadways and cross-sectional wind speed distribution.Herein,the wall roughness(Ra)in the roadway has been defined theoretically.Moreover,three-...The wall surface roughness renders a significant impact on ventilation of roadways and cross-sectional wind speed distribution.Herein,the wall roughness(Ra)in the roadway has been defined theoretically.Moreover,three-center arched roadway models for different situations are established based on the normal distribution of roof roughness.The influence of inlet velocity,roof roughness and roadway height on wind speed distribution is systematically studied by using Fluent software.At Ra=0.1 m,the simulation results reveal that the wind speed is negatively related to the distance from the wall to the point where 80%of the central wind speed is reached(DA).Also,the wind speed distribution is significantly influenced by increasing the roof roughness.However,the wind speed distribution becomes asymmetric at Ra=0.2 m and 0.3 m.Furthermore,the low-speed area(v≤1 m/s)started to concentrate on the roof with the increase of roadway height.Overall,an Ra value of<0.1 m can reduce the influence of wall roughness on wind speed distribution of the roadway,which is suggested in practical applications.展开更多
In recent years,there have been important developments in the joint analysis of the travel behavior based on discrete choice models as well as in the formulation of increasingly flexible closed-form models belonging t...In recent years,there have been important developments in the joint analysis of the travel behavior based on discrete choice models as well as in the formulation of increasingly flexible closed-form models belonging to the generalized extreme value class.The objective of this work is to describe the simultaneous choice of shopping destination and travel-to-shop mode in downtown area by making use of the cross-nested logit(CNL) structure that allows for potential spatial correlation.The analysis uses data collected in the downtown areas of Maryland-Washington,D.C.region for shopping trips,considering household,individual,land use,and travel-related characteristics.The estimation results show that the dissimilarity parameter in the CNL model is 0.37 and significant at the 95% level,indicating that the alternatives have high spatial correlation for the short shopping distance.The results of analysis reveal detailed significant influences on travel behavior of joint choice shopping destination and travel mode.Moreover,a Monte Carlo simulation for a group of scenarios arising from transportation policies and parking fees in downtown area,was undertaken to examine the impact of a change in car travel cost on the shopping destination and travel mode switching.These findings have important implications for transportation demand management and urban planning.展开更多
The method of numerical simulation was applied to investigate the effects of jet impinging plate thickness and its thermal conductivity on the local heat flux distribution along the impinging plate. The results show t...The method of numerical simulation was applied to investigate the effects of jet impinging plate thickness and its thermal conductivity on the local heat flux distribution along the impinging plate. The results show that the two factors have great effects on the heat flux distribution. The non-uniformity of the local heat-flux on the impinging plate surface gets more profound as the plate becomes thicker and thermal conductivity gets larger. When Reynolds number is 5000, the ratio of nozzle-to-plate spacing to nozzle diameter is 5 and thermal conductivity is 16W/(m·K), and even for the plate with only 25μm in thickness, the non-uniformity of the heat flux cannot be neglected. When the plate thickness is 50 μm, only when thermal conductivity is as small as 1W/(m·K), the heat flux curve can be approximately treated as an iso-heat-flux boundary. In the experimental research, a real non-iso-heat-flux boundary is treated as an iso-heat-flux boundary, which would result in under-estimated Nusselt number value in the stagnation zone and an over-estimated value outside. Such an experimental Nusselt number distribution is taken to evaluate turbulent model, and the conclusion would be drawn that the turbulent model over-predicts the stagnation heat transfer. This is one of the important reasons why many literatures reported that k-ε turbulent model dramatically over-predicts the impinging jet heat transfer in the stagnation region.展开更多
Numerical computation models of air cooling heat transfer and flow behaviors in triangular wavy fin channels(TWFC) were established with structural parameters of fins considered.The air side properties of heat transfe...Numerical computation models of air cooling heat transfer and flow behaviors in triangular wavy fin channels(TWFC) were established with structural parameters of fins considered.The air side properties of heat transfer coefficient and pressure drop are displayed with variable structural parameters of fins and inlet velocities of cooling air.Within the range of simulation,TWFC has the best comprehensive performance when inlet velocity vin=4-10 m/s.Compared with those of straight fins,the simulation results reveal that the triangular wavy fin channels are of higher heat transfer performances especially with the fin structural parameters of fin-height Fh=9.0 mm,fin-pitch Fp=2.5-3.0 mm,fin-wavelength λ=14.0-17.5 mm and fin-wave-amplitude A=1.0-1.2 mm.The correlations of both heat transfer factor and friction factor are presented,and the deviations from the experimental measurements are within 20%.展开更多
A simulation model was proposed to investigate the relationship between train delays and passenger delays and to predict the dynamic passenger distribution in a large-scale rail transit network. It was assumed that th...A simulation model was proposed to investigate the relationship between train delays and passenger delays and to predict the dynamic passenger distribution in a large-scale rail transit network. It was assumed that the time varying original-destination demand and passenger path choice probability were given. Passengers were assumed not to change their destinations and travel paths after delay occurs. CapaciW constraints of train and queue rules of alighting and boarding were taken into account. By using the time-driven simulation, the states of passengers, trains and other facilities in the network were updated every time step. The proposed methodology was also tested in a real network, for demonstration. The results reveal that short train delay does not necessarily result in passenger delays, while, on the contrary, some passengers may get benefits from the short delay. However, large initial train delay may result in not only knock-on train and passenger delays along the same line, but also the passenger delays across the entire rail transit network.展开更多
Thermal comfort and indoor air quality as well as the energy efficiency have been recognized as essential parts of sustainable building assessment. This work aims to analyze the energy conservation of the heat recover...Thermal comfort and indoor air quality as well as the energy efficiency have been recognized as essential parts of sustainable building assessment. This work aims to analyze the energy conservation of the heat recovery ventilator and to investigate the effect of the air supply arrangement. Three types of mixing ventilation are chosen for the analysis of coupling ANSYS/FLUENT (a computational fluid dynamics (CFD) program) with TRNSYS (a building energy simulation (BES) software). The adoption of mutual complementary boundary conditions for CFD and BES provides more accurate and complete information of indoor air distribution and thermal performance in buildings. A typical office-space situated in a middle storey is chosen for the analysis. The office-space is equipped with air-conditioners on the ceiling. A heat recovery ventilation system directly supplies flesh air to the office space. Its thermal performance and indoor air distribution predicted by the coupled method are compared under three types of ventilation system. When the supply and return openings for ventilation are arranged on the ceiling, there is no critical difference between the predictions of the coupled method and BES on the energy consumption of HVAC because PID control is adopted for the supply air temperature of the occupied zone. On the other hand, approximately 21% discrepancy for the heat recovery estimation in the maximum between the simulated results of coupled method and BES-only can be obviously found in the floor air supply ventilation case. The discrepancy emphasizes the necessity of coupling CFD with BES when vertical air temperature gradient exists. Our future target is to estimate the optimum design of heat recovery ventilation system to control CO2 concentration by adjusting flow rate of flesh air.展开更多
Performances and efficiencies of displacement ventilation(DV) and partial ventilation(PV) for industrial halls of different configurations as well as the heat and mass transports within the industrial halls were numer...Performances and efficiencies of displacement ventilation(DV) and partial ventilation(PV) for industrial halls of different configurations as well as the heat and mass transports within the industrial halls were numerically investigated. Three levels of Rayleigh number(5.8×1010, 1.0×1012 and 2.1×1012) and two values of source contaminant flux(5 mg/s and 50 mg/s) were considered. The inlet Reynolds numbers were 2×104, 5×104, 1.5×105 and 4.5×105 for DV and 5×105, 1×106, 2×106 and 4×106 for PV, respectively. From the results, it is concluded that the above parameters have very complex impacts on the conjugated heat and mass transports. From points of view of acceptable indoor air quality and ventilation efficiency, PV at Re=1×106 with side-located sources and 65% of the supply air extracted through floor level outlets is the best choice when Ra=5.8×1010. However, DVs at Re=5×104 and Re=1.5×105with center-located sources and floor-mounted air suppliers are the best choices for Ra=1.0×1012 and Ra=2.1×1012, respectively. When source contaminant flux reaches 50 mg/s, local extraction as a supplement of general ventilation is recommended. The results can be a first approximation to 3D numerical investigation and preliminary ventilation system design guidelines for high-rise industrial halls.展开更多
In order to investigate the temperature distribution, a three-dimensional finite element model (FEM) was developed to simulate the temperature regime in the channels of double-loop inductor, and the simulated result...In order to investigate the temperature distribution, a three-dimensional finite element model (FEM) was developed to simulate the temperature regime in the channels of double-loop inductor, and the simulated results were compared with experimental data from low load trials of a 400 kW inductor. The results of numerical simulations, such as the temperature and Joule heating rate, show reasonable correlation with experimental data. The results indicate that Joule heating rate and the temperature reach the maximum at the comers and the minimum at the centre of the cross-section area. The temperature difference between the inlet and outlet is in an inverse proportion to mass transport. Joule heating rate and the temperature are directly proportional to power frequency. It is concluded that mass transport and power frequency play a critical role in determining the temperature regime and Joule heating rate, the relative permeability of the magnetic core shows no significant influence on temperature regime and Joule heating rate, when the relative permeability varies from 5 000 to 10 000.展开更多
基金Project(12372049)supported by the National Natural Science Foundation of ChinaProject(2682023ZTPY036)supported by the Fundamental Research Funds for the Central Universities,ChinaProject(2023TPL-T06)supported by the Independent Project of State Key Laboratory of Rail Transit Vehicle System,China。
文摘Ventilation systems are critical for improving the cabin environment in high-speed trains,and their interest has increased significantly.However,whether air supply non-verticality deteriorates the cabin air environment,and the flow mechanism behind it and the degree of deterioration are not known.This study first analyzes the interaction between deflection angle and cabin flow field characteristics and ventilation performance.The results revealed that the interior temperature and pollutant concentration decreased slightly with increasing deflection angle,but resulted in significant deterioration of thermal comfort and air quality.This is evidenced by an increase in both draught rate and non-uniformity coefficient,an increase in the number of measurement points that do not satisfy the micro-wind speed and temperature difference requirements by about 5% and 15%,respectively,and an increase in longitudinal penetration of pollutants by a factor of about 5 and the appearance of locking regions at the ends of cabin.The results also show that changing the deflection pattern only affects the region of deterioration and does not essentially improve this deterioration.This study can provide reference and help for the ventilation design of high-speed trains.
文摘The reverse magnetohydrodynamic(MHD)energy bypass technology is a promising energy redis⁃tribution technology in the scramjet system,in augmented with a power generation equipment to supply the neces⁃sary long-distance flight airframe power.In this paper,a computational model of the scramjet magnetohydrody⁃namic channel is developed and verified by using the commercial software Fluent.It is found that when the mag⁃netic induction intensity is 1,2,3,4 T,the power generation efficiency is 22.5%,22.3%,22.0%,21.5%,and decreases with the increase of the magnetic induction intensity,and the enthalpy extraction rate is 0.026%,0.1%,0.21%,0.34%,and increases with the increase of the magnetic induction intensity.The deceleration ef⁃fect of electromagnetic action on the airflow in the power channel increases with the increase of magnetic induc⁃tion intensity.The stronger the magnetic field intensity,the more obvious the decreasing effect of fluid Mach num⁃ber in the channel.The power generation efficiency decreases as the magnetic induction intensity increases and the enthalpy extraction rate is reversed.As the local currents gathering at inlet and outlet of the power generation area,total temperature and enthalpy along the flow direction do not vary linearly,and there are maximum and minimum values at inlet and outlet.Increasing the number of electrodes can effectively regulate the percentage of Joule heat dissipation,which can improve the power generation efficiency.
基金Project(51874016)supported by the National Natural Science Foundation of China。
文摘In order to control the dust pollution produced by air leg rock drill in the trolley area during the excavation of long-distance single ended tunnel,the full-scale physical model of working face was established by using FLUENT software,and the numerical simulation analysis of tunnel drilling ventilation and dust removal parameters was carried out.The results show that it is difficult to control the dust pollution of the face by conventional ventilation,and the drilling dust is distributed in the range of 10 m from the face;after the introduction of the long pressure and short suction ventilation scheme,when the ratio of compressed air volume to exhaust air volume is 0.72,the height of the pressure fan is 2.5 m,the distance between the pressure fan and the palm face is 20 m,and the exhaust fan is 12 m away from the palm,the dust concentration control efficiency of the working face is increased by about 60%.Therefore,in the similar long-distance single head tunnel construction,it is appropriate to adopt the dust removal method of long-distance short suction and exhaust fan to ensure the working environment.
基金Project (51506069) supported by the National Natural Science Foundation of ChinaProject (2016YFB0600605) supported by the National Key Research and Development Program of ChinaProjects (HUST2016YXMS286,HUST2015061) supported by the Fundamental Research Funds for the Central Universities,China
文摘A numerical study is carried out on particle deposition in ducts with either convex or concave wall cavity.Results show that,if compared with smooth duct,particle deposition velocitiesVd^+increase greatly in ducts with wall cavities.More specifically,forτ+<1,Vd^+increase by about 2–4 orders of magnitude in the cases with the convex and concave wall cavities;forτ+>1,Vd^+grows relatively slower.Enhancement of particle deposition with wall cavities is caused by the following mechanisms,i.e.,interception by the wall cavities,expanded deposition area,and the enhanced flow turbulence.In general,addition of wall cavities is contributive for particle deposition,so it provides an efficient approach to remove particles,especially with small size,e.g.,PM2.5.Moreover,the convex wall cavity leads to a larger increment ofVd^+than the concave wall cavity.However,taking pressure loss into account,thoughVd^+is relatively lower,duct with the concave wall cavity is more efficient than that with the convex wall cavity.
基金Project(2017YFC0602901)supported by the National Key Research and Development Program of ChinaProject(2019zzts988)supported by the Postgraduate Independent Exploration and Innovative Project of Central South University,China。
文摘The wall surface roughness renders a significant impact on ventilation of roadways and cross-sectional wind speed distribution.Herein,the wall roughness(Ra)in the roadway has been defined theoretically.Moreover,three-center arched roadway models for different situations are established based on the normal distribution of roof roughness.The influence of inlet velocity,roof roughness and roadway height on wind speed distribution is systematically studied by using Fluent software.At Ra=0.1 m,the simulation results reveal that the wind speed is negatively related to the distance from the wall to the point where 80%of the central wind speed is reached(DA).Also,the wind speed distribution is significantly influenced by increasing the roof roughness.However,the wind speed distribution becomes asymmetric at Ra=0.2 m and 0.3 m.Furthermore,the low-speed area(v≤1 m/s)started to concentrate on the roof with the increase of roadway height.Overall,an Ra value of<0.1 m can reduce the influence of wall roughness on wind speed distribution of the roadway,which is suggested in practical applications.
基金Projects(JCYJ20120615145601342,JCYJ20130325151523015)supported by Shenzhen Science and Technology Development Funding-Fundamental Research Plan,ChinaProject(2013U-6)supported by Key Laboratory of Eco Planning & Green Building,Ministry of Education(Tsinghua University),China
文摘In recent years,there have been important developments in the joint analysis of the travel behavior based on discrete choice models as well as in the formulation of increasingly flexible closed-form models belonging to the generalized extreme value class.The objective of this work is to describe the simultaneous choice of shopping destination and travel-to-shop mode in downtown area by making use of the cross-nested logit(CNL) structure that allows for potential spatial correlation.The analysis uses data collected in the downtown areas of Maryland-Washington,D.C.region for shopping trips,considering household,individual,land use,and travel-related characteristics.The estimation results show that the dissimilarity parameter in the CNL model is 0.37 and significant at the 95% level,indicating that the alternatives have high spatial correlation for the short shopping distance.The results of analysis reveal detailed significant influences on travel behavior of joint choice shopping destination and travel mode.Moreover,a Monte Carlo simulation for a group of scenarios arising from transportation policies and parking fees in downtown area,was undertaken to examine the impact of a change in car travel cost on the shopping destination and travel mode switching.These findings have important implications for transportation demand management and urban planning.
基金Project(50376076) supported by the National Natural Science Foundation of China
文摘The method of numerical simulation was applied to investigate the effects of jet impinging plate thickness and its thermal conductivity on the local heat flux distribution along the impinging plate. The results show that the two factors have great effects on the heat flux distribution. The non-uniformity of the local heat-flux on the impinging plate surface gets more profound as the plate becomes thicker and thermal conductivity gets larger. When Reynolds number is 5000, the ratio of nozzle-to-plate spacing to nozzle diameter is 5 and thermal conductivity is 16W/(m·K), and even for the plate with only 25μm in thickness, the non-uniformity of the heat flux cannot be neglected. When the plate thickness is 50 μm, only when thermal conductivity is as small as 1W/(m·K), the heat flux curve can be approximately treated as an iso-heat-flux boundary. In the experimental research, a real non-iso-heat-flux boundary is treated as an iso-heat-flux boundary, which would result in under-estimated Nusselt number value in the stagnation zone and an over-estimated value outside. Such an experimental Nusselt number distribution is taken to evaluate turbulent model, and the conclusion would be drawn that the turbulent model over-predicts the stagnation heat transfer. This is one of the important reasons why many literatures reported that k-ε turbulent model dramatically over-predicts the impinging jet heat transfer in the stagnation region.
基金Project(50976022) supported by the National Natural Science Foundation of ChinaProject(BY2011155) supported by the Provincial Science and Technology Innovation and Transformation of Achievements of Special Fund Project of Jiangsu Province,China
文摘Numerical computation models of air cooling heat transfer and flow behaviors in triangular wavy fin channels(TWFC) were established with structural parameters of fins considered.The air side properties of heat transfer coefficient and pressure drop are displayed with variable structural parameters of fins and inlet velocities of cooling air.Within the range of simulation,TWFC has the best comprehensive performance when inlet velocity vin=4-10 m/s.Compared with those of straight fins,the simulation results reveal that the triangular wavy fin channels are of higher heat transfer performances especially with the fin structural parameters of fin-height Fh=9.0 mm,fin-pitch Fp=2.5-3.0 mm,fin-wavelength λ=14.0-17.5 mm and fin-wave-amplitude A=1.0-1.2 mm.The correlations of both heat transfer factor and friction factor are presented,and the deviations from the experimental measurements are within 20%.
基金Project(51008229)supported by the National Natural Science Foundation of ChinaProject supported by Key Laboratory of Road and Traffic Engineering of Tongji University,China
文摘A simulation model was proposed to investigate the relationship between train delays and passenger delays and to predict the dynamic passenger distribution in a large-scale rail transit network. It was assumed that the time varying original-destination demand and passenger path choice probability were given. Passengers were assumed not to change their destinations and travel paths after delay occurs. CapaciW constraints of train and queue rules of alighting and boarding were taken into account. By using the time-driven simulation, the states of passengers, trains and other facilities in the network were updated every time step. The proposed methodology was also tested in a real network, for demonstration. The results reveal that short train delay does not necessarily result in passenger delays, while, on the contrary, some passengers may get benefits from the short delay. However, large initial train delay may result in not only knock-on train and passenger delays along the same line, but also the passenger delays across the entire rail transit network.
基金Project supported by Grant-in-Aid for Scientific Research (JSPS KAKENHI for Young Scientists (S), 21676005)
文摘Thermal comfort and indoor air quality as well as the energy efficiency have been recognized as essential parts of sustainable building assessment. This work aims to analyze the energy conservation of the heat recovery ventilator and to investigate the effect of the air supply arrangement. Three types of mixing ventilation are chosen for the analysis of coupling ANSYS/FLUENT (a computational fluid dynamics (CFD) program) with TRNSYS (a building energy simulation (BES) software). The adoption of mutual complementary boundary conditions for CFD and BES provides more accurate and complete information of indoor air distribution and thermal performance in buildings. A typical office-space situated in a middle storey is chosen for the analysis. The office-space is equipped with air-conditioners on the ceiling. A heat recovery ventilation system directly supplies flesh air to the office space. Its thermal performance and indoor air distribution predicted by the coupled method are compared under three types of ventilation system. When the supply and return openings for ventilation are arranged on the ceiling, there is no critical difference between the predictions of the coupled method and BES on the energy consumption of HVAC because PID control is adopted for the supply air temperature of the occupied zone. On the other hand, approximately 21% discrepancy for the heat recovery estimation in the maximum between the simulated results of coupled method and BES-only can be obviously found in the floor air supply ventilation case. The discrepancy emphasizes the necessity of coupling CFD with BES when vertical air temperature gradient exists. Our future target is to estimate the optimum design of heat recovery ventilation system to control CO2 concentration by adjusting flow rate of flesh air.
基金Project(2011BAJ03B07)supported by National Twelve Five-year Science and Technology Support Program of ChinaProject supported by the China Scholarship Council+1 种基金Project(51276057,51376198)supported by the National Natural Science Foundation of ChinaProject(CX2014B064)supported by Hunan Provincial Innovation Foundation for Postgraduate,China
文摘Performances and efficiencies of displacement ventilation(DV) and partial ventilation(PV) for industrial halls of different configurations as well as the heat and mass transports within the industrial halls were numerically investigated. Three levels of Rayleigh number(5.8×1010, 1.0×1012 and 2.1×1012) and two values of source contaminant flux(5 mg/s and 50 mg/s) were considered. The inlet Reynolds numbers were 2×104, 5×104, 1.5×105 and 4.5×105 for DV and 5×105, 1×106, 2×106 and 4×106 for PV, respectively. From the results, it is concluded that the above parameters have very complex impacts on the conjugated heat and mass transports. From points of view of acceptable indoor air quality and ventilation efficiency, PV at Re=1×106 with side-located sources and 65% of the supply air extracted through floor level outlets is the best choice when Ra=5.8×1010. However, DVs at Re=5×104 and Re=1.5×105with center-located sources and floor-mounted air suppliers are the best choices for Ra=1.0×1012 and Ra=2.1×1012, respectively. When source contaminant flux reaches 50 mg/s, local extraction as a supplement of general ventilation is recommended. The results can be a first approximation to 3D numerical investigation and preliminary ventilation system design guidelines for high-rise industrial halls.
基金Project(50876116) supported by the National Natural Science Foundation of ChinaProject(2007CK3077) supported by the Innovative Program of Hunan Science and Technology Agency, ChinaProject(1343-77225) supported by the Graduate School of Central South University, China
文摘In order to investigate the temperature distribution, a three-dimensional finite element model (FEM) was developed to simulate the temperature regime in the channels of double-loop inductor, and the simulated results were compared with experimental data from low load trials of a 400 kW inductor. The results of numerical simulations, such as the temperature and Joule heating rate, show reasonable correlation with experimental data. The results indicate that Joule heating rate and the temperature reach the maximum at the comers and the minimum at the centre of the cross-section area. The temperature difference between the inlet and outlet is in an inverse proportion to mass transport. Joule heating rate and the temperature are directly proportional to power frequency. It is concluded that mass transport and power frequency play a critical role in determining the temperature regime and Joule heating rate, the relative permeability of the magnetic core shows no significant influence on temperature regime and Joule heating rate, when the relative permeability varies from 5 000 to 10 000.