自动电压控制中强耦合电厂的协调控制方法 被引量:9
1
作者 王彬 郭庆来 +3 位作者 孙宏斌 汤磊 张伯明 田俊杰 《电力系统自动化》 EI CSCD 北大核心 2015年第12期165-171,共7页
为解决强耦合电厂间无功出力不均衡的问题,提出了强耦合电厂间的无功电压协调控制(厂厂协调)方法。该方法建立包含相互强耦合的厂厂协调组,并作为协调单元;定义厂厂协调组无功负载率偏差指标,若中枢母线电压未调节到位,进行考虑厂厂协... 为解决强耦合电厂间无功出力不均衡的问题,提出了强耦合电厂间的无功电压协调控制(厂厂协调)方法。该方法建立包含相互强耦合的厂厂协调组,并作为协调单元;定义厂厂协调组无功负载率偏差指标,若中枢母线电压未调节到位,进行考虑厂厂协调约束的协调二级电压控制,使得在中枢母线电压追踪优化设定值的同时,保证强耦合电厂间的无功负载率偏差满足控制要求;若中枢母线电压已调节到位,进行基于厂厂协调目标的无功校正控制,降低强耦合电厂间的无功负载率偏差,并保证中枢母线电压维持在控制死区范围内;在传统电压调节指令的基础上增加无功调节指令,抑制强耦合电厂间可能出现的不合理无功分布或无功波动。文中成果已在国内多个网、省级电网得到实际应用,仿真及实际运行效果表明该方法可有效减少强耦合电厂间的不合理无功分布。 展开更多
关键词 控制中心 自动电压控制 协调控制 强耦合电厂 无功负载率 能量管理 运行控制
在线阅读 下载PDF
Middle range wireless power transfer systems with multiple resonators 被引量:1
2
作者 陈新 张桂香 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第6期2127-2136,共10页
The equivalent two-port network model of a middle range wireless power transfer(WPT) system was presented based on strongly coupled multiple resonators. The key parameters of the WPT system include self-inductance, re... The equivalent two-port network model of a middle range wireless power transfer(WPT) system was presented based on strongly coupled multiple resonators. The key parameters of the WPT system include self-inductance, resistance, parasitic capacitance, mutual inductance and S-parameters of coils & resonators were analyzed. The impedance matching method was used to optimize load power and transmission efficiency of the multi-resonator WPT system, and the impedance matching method was realized through adjusting the distances between the coils and resonators. Experiments show that the impedance matching method can effectively improve load power and transmission efficiency for middle range wireless power transfer systems with multiple resonators, at distances up to 3 times the coil radius with efficiency more than 70% and load power also close to 3.5 W. 展开更多
关键词 wireless power transfer middle range multiple resonators S-PARAMETERS two-port network impedance matching
在线阅读 下载PDF
Two new methods for power flow tracing using bus power balance equations
3
作者 Noradin Ghadimi 《Journal of Central South University》 SCIE EI CAS 2014年第7期2712-2718,共7页
Two new methods were presented for power flow tracing(PFT).These two methods were compared and the results were discussed in detail.Both methods use the active and reactive power balance equations at each bus in order... Two new methods were presented for power flow tracing(PFT).These two methods were compared and the results were discussed in detail.Both methods use the active and reactive power balance equations at each bus in order to solve the tracing problem.The first method considers the proportional sharing assumption while the second one uses the circuit laws to find the relationship between power inflows and outflows through each line,generator and load connected to each bus of the network.Both methods are able to handle loop flow and loss issues in tracing problem.A formulation is also proposed to find the share of each unit in provision of each load.These methods are applied to find the producer and consumer's shares on the cost of transmission for each line in different case studies.As the results of these studies show,both methods can effectively solve the PFT problem. 展开更多
关键词 load contribution power flow tracing proportional/non-proportional sharing network Zbus transmission cost allocation
在线阅读 下载PDF
Coordination of multiple grid-connected inverters for harmonic compensation
4
作者 郭晓瑞 郭吉丰 王剑 《Journal of Central South University》 SCIE EI CAS 2014年第8期3126-3132,共7页
For multiple grid-connected inverters with active filter function,it makes sense to regulate every unit to output maximum active power from photovoltaic arrays,as well as eliminate the harmonic due to the non-linear l... For multiple grid-connected inverters with active filter function,it makes sense to regulate every unit to output maximum active power from photovoltaic arrays,as well as eliminate the harmonic due to the non-linear loads connected to the electric networks.Naturally,a centralized control coordination strategy was proposed for the purpose of high facility utilization,good harmonic compensation ability and unwanted overcompensation condition.Based on a vector decoupling control scheme and generalized instantaneous reactive power theory,the solution was to allocate the harmonic eliminating task for every inverter according to the instantaneous power margin of each.The grid current always keeps sinusoidal in spite of non-linear load change and output active power change for any inverter.The simulation results validate the efficacy of the proposed coordination strategy. 展开更多
关键词 active filter HARMONICS grid-connected inverter decoupling control COORDINATION
在线阅读 下载PDF