A high current, AC waveform controller with C-type body frame of spot welder(75 k VA), was examined for the electrode actuating system whose pneumatically driven system has been redesigned and refitted for the servo b...A high current, AC waveform controller with C-type body frame of spot welder(75 k VA), was examined for the electrode actuating system whose pneumatically driven system has been redesigned and refitted for the servo based system without any vertical spring assistance in the 50 mm movable distance. Moreover, the pressing mechanism was carefully handled during the entire pressing tasks as to ensure that no catastrophic reaction happens for the electrodes' caps, electrodes' holders as well as the other part of mechanical assembly. With the mechanically originated-pneumatic and also the converted-servo systems, the stainless steels are welded for both systems to characterize the improvements. While the welding processes were carried out, the electrical signals have been captured to compute the signals' representation of entire sequences. Later, the welded samples were underwent the tensile shear test, metallurgical observation and hardness test. The analytical results show distinct changes in the force profiles which has led to profound changes in mechanical properties of welded specimens.展开更多
This paper proposed the reclosing method in distribution system with battery energy storage system(BESS)using wavelet transform(WT).The proposed method performs the WT of load current and then calculates the absolute ...This paper proposed the reclosing method in distribution system with battery energy storage system(BESS)using wavelet transform(WT).The proposed method performs the WT of load current and then calculates the absolute value of slope of detail coefficient.The mother wavelet used is db4of level6.The fault clearing is detected using the rapid increase of this value.After the detection of fault clearing,the reclosing is performed.To verify the proposed method,various simulations according to the fault clearing times,fault resistances,and fault lengths are performed using EMTP.The simulation results show that fault clearing can be detected using proposed absolute value of slope of detail coefficient and hence the reclosing can be performed successfully.展开更多
Matrix Converter(MC),a direct AC-ACconverter which is capable of bidirectional powerflow,unity input power factor control and efficiencyimprovement.Thus,it is more suitable for integrationof motor machine and power el...Matrix Converter(MC),a direct AC-ACconverter which is capable of bidirectional powerflow,unity input power factor control and efficiencyimprovement.Thus,it is more suitable for integrationof motor machine and power electronics systems.This paper investigated a novel generationsystem,which is composed of hybrid excitedsynchronous generator(HESG)and matrix converter(MC),as shown in Fig.1.Owing to the voltage clampcircuit,this structure waived an external DC sourcecommonly used for the excitation for HESG.Thevoltage clamp circuit shared a DC bus with afull-bridge converter and the excitation winding ofHESG is directly connected to the output of thefull-bridge converter achieving a bidirectional currentflow.展开更多
文摘A high current, AC waveform controller with C-type body frame of spot welder(75 k VA), was examined for the electrode actuating system whose pneumatically driven system has been redesigned and refitted for the servo based system without any vertical spring assistance in the 50 mm movable distance. Moreover, the pressing mechanism was carefully handled during the entire pressing tasks as to ensure that no catastrophic reaction happens for the electrodes' caps, electrodes' holders as well as the other part of mechanical assembly. With the mechanically originated-pneumatic and also the converted-servo systems, the stainless steels are welded for both systems to characterize the improvements. While the welding processes were carried out, the electrical signals have been captured to compute the signals' representation of entire sequences. Later, the welded samples were underwent the tensile shear test, metallurgical observation and hardness test. The analytical results show distinct changes in the force profiles which has led to profound changes in mechanical properties of welded specimens.
文摘This paper proposed the reclosing method in distribution system with battery energy storage system(BESS)using wavelet transform(WT).The proposed method performs the WT of load current and then calculates the absolute value of slope of detail coefficient.The mother wavelet used is db4of level6.The fault clearing is detected using the rapid increase of this value.After the detection of fault clearing,the reclosing is performed.To verify the proposed method,various simulations according to the fault clearing times,fault resistances,and fault lengths are performed using EMTP.The simulation results show that fault clearing can be detected using proposed absolute value of slope of detail coefficient and hence the reclosing can be performed successfully.
文摘Matrix Converter(MC),a direct AC-ACconverter which is capable of bidirectional powerflow,unity input power factor control and efficiencyimprovement.Thus,it is more suitable for integrationof motor machine and power electronics systems.This paper investigated a novel generationsystem,which is composed of hybrid excitedsynchronous generator(HESG)and matrix converter(MC),as shown in Fig.1.Owing to the voltage clampcircuit,this structure waived an external DC sourcecommonly used for the excitation for HESG.Thevoltage clamp circuit shared a DC bus with afull-bridge converter and the excitation winding ofHESG is directly connected to the output of thefull-bridge converter achieving a bidirectional currentflow.