期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
EFFECTS OF ANTICOAGULATION PROTEIN DEFECT IN MATERNAL PLASMA ON SPONTANEOUS ABORTION 被引量:1
1
作者 Chun-meiBai Shui-qingMa Ming-yingGai Lian-kaiFan Feng-yanRen Guang-shengFan 《Chinese Medical Sciences Journal》 CAS CSCD 2004年第4期290-292,共3页
Objective To investigate the mechanism of anticoagulation protein defect in the pathogenesis of unexplained recurrent miscarriage. Methods Fifty-seven patients with a history of unexplained abortion were enrolled as t... Objective To investigate the mechanism of anticoagulation protein defect in the pathogenesis of unexplained recurrent miscarriage. Methods Fifty-seven patients with a history of unexplained abortion were enrolled as the investigation group for tests of protein C, protein S, antithrombinⅢ(AT-Ⅲ), as well as activated protein C resistance (APC-R). The control group con-sisted of fifty healthy women with a history of normal pregnancy and delivery. Blood samples were obtained for measuring serum activity of protein C, protein S, AT-Ⅲ, and APC-R. Patients with positive APC-R were tested for factorⅤ(FⅤ) Lei-den gene mutation by PCR-RFLP method. Results Of the 57 patients, 12 (21.1%), 1 (1.8%), and 5 (8.8%) cases were found with protein S, protein C, and AT-Ⅲdeficiency respectively, and 13 (22.8%) cases with positive results of APC-R. Of the control group, no protein C or AT-Ⅲdeficiency was ever found, whereas 2 (4.0%) volunteers were presented with protein S deficiency and 3 (6.0%) with positive results of APC-R. No FⅤLeiden gene mutation was identified in all the patients with positive APC-R results. Late spontan-eous abortion cases had higher incidence of anticoagulation protein defect than the early cases. Conclusion Anticoagulation protein defect may play a role in the pathogenesis of fetal loss, especially for those occurr-ing in late stage of pregnancy. 展开更多
关键词 protein S deficiency protein C deficiency activated protein C resistance spontaneous abortion
在线阅读 下载PDF
Anticoagulation early after mechanical heart valve replacement 被引量:2
2
作者 Qin Chuan Xiao Yingbin Chen Lin 《Journal of Medical Colleges of PLA(China)》 CAS 2010年第1期24-28,共5页
Objective: To explore the changes of coagulation activity and the characters of anticoagulation early after mechanical heart valve replacement. Methods: All patients only took warfarin orally for anticoagulation. Th... Objective: To explore the changes of coagulation activity and the characters of anticoagulation early after mechanical heart valve replacement. Methods: All patients only took warfarin orally for anticoagulation. The predicted international normalized ratio (INR) was 1.5 to 2.0. Several coagulation markers were monitored early after valve replacement. Complications associated with anticoagulation were recorded and analyzed. The patients were divided into three groups based on the number and position of mechanical valve prothesis, including group M (mitral valve replacement), group A (aortic valve replacement) and group D (mitral and aortic valve replacement).Comparison was made between the three groups. Results: Three events of mild cerebral embolism and five events of mild bleeding occurred during the early postoperative period. One patient suffered from mild cerebral embolism on the 4th day after operation, accompanied by large volume of pericardial drainage. Two patients with bleeding had lower INRs than predicted range. However, INR in one patient with mild cerebral embolism was in the predicted range. There was no significant difference in thrombo time (TT), activated partial thromboplastin time (APTT) and 1NR on the 3rd day after operation compared to those before operation; meanwhile, plasma fibrinogen (FIB) concentration was higher than that before operation (P〈0.05). 1NR had no significant changes on the 2nd day after the beginning of anticoagulation compared to that before operation; however, 1NR was significantly elevated on the 4th day (P〈0.05). Warfarin doses and INRs were similar among the three groups, but FIB concentrations in plasma were higher in groups M and D than in group A (P〈0.01). Conclusion: Hypercoagulabale state exists early after mechanical heart valve replacement. When anticoagulation begins is determined by the change of coagulation markers, not by the volume of chest or pericardial drainage. INR can not accurately reflect the coagulation state sometimes, especially during the first 3 days after anticoagulation. The number and position of mechanical valve prothesis could affect coagulation state. Therefore, anticoagulation therapy should be regulated accordingly. 展开更多
关键词 ANTICOAGULATION Mechanical heart valve replacement International normalized ratio WARFARIN
在线阅读 下载PDF
Thrombus precursor protein for monitoring anticoagulation in patients with mechanical valve prosthesis
3
作者 Qin Chuan Xiao Yingbin 《Journal of Medical Colleges of PLA(China)》 CAS 2009年第1期45-49,共5页
Objective: To evaluate the plasma concentration of thrombus precursor protein (TPP) in patients after mechanical heart valve replacement, and to explore whether it can be used as a marker for monitoring anticoagulatio... Objective: To evaluate the plasma concentration of thrombus precursor protein (TPP) in patients after mechanical heart valve replacement, and to explore whether it can be used as a marker for monitoring anticoagulation. Methods: Totally 60 patients who took warfarin after mitral valve replacement and 20 control patients with non-valvular heart diseases were subjected in this study. Their plasma TPP concentration and international normalized ratio (INR) were determined, and compared not only between the anticoagulant patients and the control patients, but also between the patients with atrial fibrillaiton (AF, n=37) and the patients with sinus rhythm (SR, n=23) after mechanical valve replacement. The relationship between plasma TPP concentration and INR in the 60 anticoagulant patients was analyzed with linear regression. Results: It was found that the anticoagulant therapy effectively decreased plasma TPP concentration and elevated INR. In the anticoagulant group, the patients with AF had higher plasma TPP concentration than the others with sinus rhythm (P<0.05), although there was no significant difference in INR level between these 2 groups of patients (P>0.05). No significant correlation was found between plasma TPP concentration and INR in the anticoagulant patients (P>0.05). INR did not accord with plasma TPP concentration in several patients. Conclusion: INR can’t reflect the coagulation status and guide the anticoagulation correctly sometimes; TPP may be a valuable assistant marker for monitoring anticoagulation in patients with mechanical heart valve prothesis; Patients with AF may require higher density of anticoagulation and TPP is strongly suggested to be monitored in these patients. 展开更多
关键词 ANTICOAGULATION Mechanical valve replacement Thrombus precursor protein International normalized ratio
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部