期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
采用手持式光度计的△I测量模式快速测定尿样中白蛋白 被引量:6
1
作者 陈焕文 金钦汉 +1 位作者 杨立泉 罗贵民 《高等学校化学学报》 SCIE EI CAS CSCD 北大核心 2001年第6期928-930,共3页
A portable spectrophotometer developed by Changchun R & D Center for Analytical Instruments, which combines ΔI measurement mode and a measurement mode together with a high sensitivity, good accuracy and low cost,... A portable spectrophotometer developed by Changchun R & D Center for Analytical Instruments, which combines ΔI measurement mode and a measurement mode together with a high sensitivity, good accuracy and low cost, is employed to replace the traditional spectrophotometer and the sensitivity is enhanced. Therefore, a new rapid method with low cost and simplicity in operation for protein determination is developed. For this method, the linear range is shown to be 0—0 74 μg/mL, the detection limit is 0 01 μg/mL, and the analysis can be completed within 5 min. The albumin in urine is determined and all the results are confirmed by the standard method. Because of the rapid analysis speed, less expenditure, more convenience and simplicity in operation of this method, it is possible to use this method to diagnose glycosuric nephropathy at an early stage, even do it at home. 展开更多
关键词 手持式光度计 △I测量模式 白蛋白 尿样 测定 临床检验 光度
在线阅读 下载PDF
手持式消光光度计的研制及用于掺杂牛奶的现场快速检测 被引量:7
2
作者 花榕 张兴磊 +3 位作者 周跃明 胡燕 张燮 陈焕文 《岩矿测试》 CAS CSCD 2008年第3期169-173,共5页
自行设计新型消光池,研制了一种廉价的手持式消光光度计,并在此基础上建立了掺杂牛奶的现场检测方法。实验结果表明,所建立的方法无需对牛奶进行复杂处理,可对常见掺杂(如搀水、米汤、奶粉、豆浆、尿素等)牛奶和含重金属离子汞的牛奶,... 自行设计新型消光池,研制了一种廉价的手持式消光光度计,并在此基础上建立了掺杂牛奶的现场检测方法。实验结果表明,所建立的方法无需对牛奶进行复杂处理,可对常见掺杂(如搀水、米汤、奶粉、豆浆、尿素等)牛奶和含重金属离子汞的牛奶,进行现场检测。由于采用新型消光池,有效地减小了蛋白质粒子因重力沉降所带来的误差,能够成功区分同密度劣质牛奶。该方法灵敏度高,对掺水牛奶的检出限低于2%,对重金属(如汞)的检出限为0.005μg/g。单个样品测定时间不到2 min,适合于牛奶品质的现场快速检测。 展开更多
关键词 牛奶 掺杂 手持式消光光度计 散射 现场快速检测
在线阅读 下载PDF
溶解氧的快速现场测定 被引量:10
3
作者 杨蕊 陈焕文 +2 位作者 张寒琦 于爱民 金钦汉 《高等学校化学学报》 SCIE EI CAS CSCD 北大核心 2002年第8期1501-1503,共3页
The indigo carmine was reduced by using cheap,easily attainable and non poisonous reagents. Therefore, a special reagent was developed to measure the concentration of dissolved oxygen in water in situ . The molar abso... The indigo carmine was reduced by using cheap,easily attainable and non poisonous reagents. Therefore, a special reagent was developed to measure the concentration of dissolved oxygen in water in situ . The molar absorption coefficient of the method is 1 35×10 4, and its dynamic linear range is 0-27 mg/L linearity coefficient of 0 997. The most oxidizing species, such as Cl 2, ClO -, Cu 2+ , Fe 3+ , V 5+ , and As(Ⅴ), do not interfere the determination. It takes no more than 1 min to analyze one sample. The method was applied to determining some practical samples and all the results obtained were satisfactory. 展开更多
关键词 溶解氧 现场测定 手持式光度计 水体污染 环境监测
在线阅读 下载PDF
甲基丙烯酸甲酯聚合反应的快速检测 被引量:1
4
作者 花榕 周跃明 +3 位作者 张兴磊 胡燕 张燮 陈焕文 《东华理工大学学报(自然科学版)》 CAS 2008年第2期182-186,共5页
基于光的Mie散射理论,建立了一种用于甲基丙烯酸甲酯(MMA)聚合反应的快速检测方法,并且考察了交联壳聚糖/银(Ⅰ)/亚硫酸钠引发甲基丙烯酸甲酯的聚合反应中Na2SO3浓度、单体浓度、反应温度、反应时间、交联壳聚糖/银(Ⅰ)量等参数的改变... 基于光的Mie散射理论,建立了一种用于甲基丙烯酸甲酯(MMA)聚合反应的快速检测方法,并且考察了交联壳聚糖/银(Ⅰ)/亚硫酸钠引发甲基丙烯酸甲酯的聚合反应中Na2SO3浓度、单体浓度、反应温度、反应时间、交联壳聚糖/银(Ⅰ)量等参数的改变对反应体系的影响。如果借助手持式消光光度计,还可以用于甲基丙烯酸甲酯聚合反应的现场检测,方法具有仪器结构简单、稳定性高、操作方便等优点,单个样品测定时间不到2min。 展开更多
关键词 MMA 聚合反应 手持式消光光度计 快速检测 现场
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部