Digital radiographic(DR)testing equipment has been widely promoted and applied in the inspection of circumferential welds in oil and gas pipelines.In order to establish a comprehensive quality control system for digit...Digital radiographic(DR)testing equipment has been widely promoted and applied in the inspection of circumferential welds in oil and gas pipelines.In order to establish a comprehensive quality control system for digital radiographic testing and fully evaluate the integrated system inspection ability of equipment,personnel,and processes,a scientific and standardized evaluation method to the system is very necessary.Here investigates the precedents of relevant non-destructive testing evaluation methods at home and abroad,considers the testing characteristics of DR equipment,develops a complete set of DR testing system evaluation procedures.It deeply studies the adaptability methods of program processes from defect production to slicing processing and data statistical calculation for digital radiographic testing evaluation.To check the repeatability and reliability of the detectable system,five process welds with 200 real metallographic defects were fabricated in the laboratory.From the detected results,the DR system has good repeatability in image quality,and the detectable defect size reaches 0.85 mm under achieving 90%detection probability at a confidence level of 95%,the error of detected defect length is±2 mm,and the error of detected defect localization is±5 mm.The qualitative and quantitative detection of defects are accurate and reliable.The test further confirmed the reliable detection ability of the DR detection system,and fully validated the scientific and practical evaluation method designed.The research on the evaluation test method can serve as an important link in the quality control system for the on-site application of digital ray equipment in long-distance pipelines.The designed program,test,and evaluation content can serve as an important basis for the formulation of relevant specifications or standards.展开更多
建立了高效液相色谱法测定呈味核苷酸二钠(IMP和GMP)含量的方法.以四丁基磷酸铵和磷酸二氢钾配以一定比例的乙腈为流动相,采用高耐水系Waters RP 18色谱柱,通过色谱条件的优化,获得了定性定量重复性相对标准偏差<2%的标准品色谱图,其...建立了高效液相色谱法测定呈味核苷酸二钠(IMP和GMP)含量的方法.以四丁基磷酸铵和磷酸二氢钾配以一定比例的乙腈为流动相,采用高耐水系Waters RP 18色谱柱,通过色谱条件的优化,获得了定性定量重复性相对标准偏差<2%的标准品色谱图,其中,IMP标准曲线在60~600μg/mL范围内的线性相关系数为R=1.0000,GMP标准曲线在50~480μg/mL范围内的线性相关系数为R=0.999 9.测得某品牌的鸡精内IMP质量含量为0.54%,GMP质量含量为0.60%,两次测定结果的精密度GMP为0.73%,IMP为1.17%.展开更多
文摘Digital radiographic(DR)testing equipment has been widely promoted and applied in the inspection of circumferential welds in oil and gas pipelines.In order to establish a comprehensive quality control system for digital radiographic testing and fully evaluate the integrated system inspection ability of equipment,personnel,and processes,a scientific and standardized evaluation method to the system is very necessary.Here investigates the precedents of relevant non-destructive testing evaluation methods at home and abroad,considers the testing characteristics of DR equipment,develops a complete set of DR testing system evaluation procedures.It deeply studies the adaptability methods of program processes from defect production to slicing processing and data statistical calculation for digital radiographic testing evaluation.To check the repeatability and reliability of the detectable system,five process welds with 200 real metallographic defects were fabricated in the laboratory.From the detected results,the DR system has good repeatability in image quality,and the detectable defect size reaches 0.85 mm under achieving 90%detection probability at a confidence level of 95%,the error of detected defect length is±2 mm,and the error of detected defect localization is±5 mm.The qualitative and quantitative detection of defects are accurate and reliable.The test further confirmed the reliable detection ability of the DR detection system,and fully validated the scientific and practical evaluation method designed.The research on the evaluation test method can serve as an important link in the quality control system for the on-site application of digital ray equipment in long-distance pipelines.The designed program,test,and evaluation content can serve as an important basis for the formulation of relevant specifications or standards.
文摘建立了高效液相色谱法测定呈味核苷酸二钠(IMP和GMP)含量的方法.以四丁基磷酸铵和磷酸二氢钾配以一定比例的乙腈为流动相,采用高耐水系Waters RP 18色谱柱,通过色谱条件的优化,获得了定性定量重复性相对标准偏差<2%的标准品色谱图,其中,IMP标准曲线在60~600μg/mL范围内的线性相关系数为R=1.0000,GMP标准曲线在50~480μg/mL范围内的线性相关系数为R=0.999 9.测得某品牌的鸡精内IMP质量含量为0.54%,GMP质量含量为0.60%,两次测定结果的精密度GMP为0.73%,IMP为1.17%.