期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Evaluation Test Research of DR Inspection System for Circumferential Welds in Long Distance Pipeline
1
作者 WANG Changjiang WANG Xue +4 位作者 ZHANG Shimin ZHAO Yan LYU Xinyu ZHONG Qian ZHOU Guangyan 《材料导报》 EI CAS CSCD 北大核心 2024年第22期223-229,共7页
Digital radiographic(DR)testing equipment has been widely promoted and applied in the inspection of circumferential welds in oil and gas pipelines.In order to establish a comprehensive quality control system for digit... Digital radiographic(DR)testing equipment has been widely promoted and applied in the inspection of circumferential welds in oil and gas pipelines.In order to establish a comprehensive quality control system for digital radiographic testing and fully evaluate the integrated system inspection ability of equipment,personnel,and processes,a scientific and standardized evaluation method to the system is very necessary.Here investigates the precedents of relevant non-destructive testing evaluation methods at home and abroad,considers the testing characteristics of DR equipment,develops a complete set of DR testing system evaluation procedures.It deeply studies the adaptability methods of program processes from defect production to slicing processing and data statistical calculation for digital radiographic testing evaluation.To check the repeatability and reliability of the detectable system,five process welds with 200 real metallographic defects were fabricated in the laboratory.From the detected results,the DR system has good repeatability in image quality,and the detectable defect size reaches 0.85 mm under achieving 90%detection probability at a confidence level of 95%,the error of detected defect length is±2 mm,and the error of detected defect localization is±5 mm.The qualitative and quantitative detection of defects are accurate and reliable.The test further confirmed the reliable detection ability of the DR detection system,and fully validated the scientific and practical evaluation method designed.The research on the evaluation test method can serve as an important link in the quality control system for the on-site application of digital ray equipment in long-distance pipelines.The designed program,test,and evaluation content can serve as an important basis for the formulation of relevant specifications or standards. 展开更多
关键词 digital ray evaluation test REPEATABILITY RELIABILITY
在线阅读 下载PDF
紫外可见及二极管阵列检测器高效液相色谱仪检定时常见问题及解决方法 被引量:2
2
作者 姜美沙 罗嘉瑞 《化学分析计量》 CAS 2012年第4期84-85,共2页
按照国家计量检定规程,分析了检定紫外–可见及二极管阵列检测器高效液相色谱仪的主要计量指标时常见问题和产生的原因,并提出了解决方法。
关键词 紫外-可见及二极管阵列检测器高效液相色谱仪 基线漂移 最小检测浓度 定性重复性 定量重复性
在线阅读 下载PDF
鸡精中呈味核苷酸二钠的高效液相色谱法测定 被引量:6
3
作者 相丽新 杨道兴 +1 位作者 魏彦梅 颜丙霞 《北京工商大学学报(自然科学版)》 CAS 2011年第6期32-34,39,共4页
建立了高效液相色谱法测定呈味核苷酸二钠(IMP和GMP)含量的方法.以四丁基磷酸铵和磷酸二氢钾配以一定比例的乙腈为流动相,采用高耐水系Waters RP 18色谱柱,通过色谱条件的优化,获得了定性定量重复性相对标准偏差<2%的标准品色谱图,其... 建立了高效液相色谱法测定呈味核苷酸二钠(IMP和GMP)含量的方法.以四丁基磷酸铵和磷酸二氢钾配以一定比例的乙腈为流动相,采用高耐水系Waters RP 18色谱柱,通过色谱条件的优化,获得了定性定量重复性相对标准偏差<2%的标准品色谱图,其中,IMP标准曲线在60~600μg/mL范围内的线性相关系数为R=1.0000,GMP标准曲线在50~480μg/mL范围内的线性相关系数为R=0.999 9.测得某品牌的鸡精内IMP质量含量为0.54%,GMP质量含量为0.60%,两次测定结果的精密度GMP为0.73%,IMP为1.17%. 展开更多
关键词 高效液相色谱 呈味核苷酸二钠 定性定量重复性 相对标准偏差 鸡精
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部