目前,我国尚缺乏液化场地桩-土-桥梁结构地震相互作用分析的合理数值模型与简化分析方法。鉴于此,直接针对振动台试验,基于非线性文克尔地基梁模型,考虑桩周参振土的质量惯性力、上部结构的惯性力、土体辐射阻尼等效应,建立了液化场地桩...目前,我国尚缺乏液化场地桩-土-桥梁结构地震相互作用分析的合理数值模型与简化分析方法。鉴于此,直接针对振动台试验,基于非线性文克尔地基梁模型,考虑桩周参振土的质量惯性力、上部结构的惯性力、土体辐射阻尼等效应,建立了液化场地桩-土-桥梁结构地震相互作用的p-y曲线分析模型,并给出相应的简化方法。针对振动台试验进行了0.1g El Centro波输入下的分析,验证了桩-土地震相互作用分析方法的正确性,并且推荐了计算参数的合理选取方法,可用于液化场地桩-土地震相互作用的分析。提出的液化场地桩-土地震相互作用p-y曲线简化分析方法,为实际桥梁桩基抗震设计与分析提供一定参考。展开更多
Bridges crossing active faults are more likely to suffer serious damage or even collapse due to the wreck capabilities of near-fault pulses and surface ruptures under earthquakes.Taking a high-speed railway simply-sup...Bridges crossing active faults are more likely to suffer serious damage or even collapse due to the wreck capabilities of near-fault pulses and surface ruptures under earthquakes.Taking a high-speed railway simply-supported girder bridge with eight spans crossing an active strike-slip fault as the research object,a refined coupling dynamic model of the high-speed train-CRTS III slab ballastless track-bridge system was established based on ABAQUS.The rationality of the established model was thoroughly discussed.The horizontal ground motions in a fault rupture zone were simulated and transient dynamic analyses of the high-speed train-track-bridge coupling system under 3-dimensional seismic excitations were subsequently performed.The safe running speed limits of a high-speed train under different earthquake levels(frequent occurrence,design and rare occurrence)were assessed based on wheel-rail dynamic(lateral wheel-rail force,derailment coefficient and wheel-load reduction rate)and rail deformation(rail dislocation,parallel turning angle and turning angle)indicators.Parameter optimization was then investigated in terms of the rail fastener stiffness and isolation layer friction coefficient.Results of the wheel-rail dynamic indicators demonstrate the safe running speed limits for the high-speed train to be approximately 200 km/h and 80 km/h under frequent and design earthquakes,while the train is unable to run safely under rare earthquakes.In addition,the rail deformations under frequent,design and rare earthquakes meet the safe running requirements of the high-speed train for the speeds of 250,100 and 50 km/h,respectively.The speed limits determined for the wheel-rail dynamic indicators are lower due to the complex coupling effect of the train-track-bridge system under track irregularity.The running safety of the train was improved by increasing the fastener stiffness and isolation layer friction coefficient.At the rail fastener lateral stiffness of 60 kN/mm and isolation layer friction coefficients of 0.9 and 0.8,respectively,the safe running speed limits of the high-speed train increased to 250 km/h and 100 km/h under frequent and design earthquakes,respectively.展开更多
In order to analyze the seismic response characteristics of pile-supported structure,a computational model considering pile-soil-structure interaction effect was established by finite element method.Then,numerical imp...In order to analyze the seismic response characteristics of pile-supported structure,a computational model considering pile-soil-structure interaction effect was established by finite element method.Then,numerical implementation was made in time domain.At the same time,a simplified approximation for seismic response analysis of pile-soil-structure system was briefly presented.Furthermore,comparative study was performed for an engineering example.Through comparative analysis,it is shown that the results obtained by the simplified method well agree with those achieved by the finite element method.These results show that spectrum characteristics and intensity of input earthquakes are two important factors that can notablely influence the seismic response characteristics of superstructure.When the input ground motion acceleration amplitude gradually increases from 1 to 4 m/s2,the acceleration of pier top will increase,but it will not be simply proportional to the increase of input acceleration amplitude.展开更多
文摘目前,我国尚缺乏液化场地桩-土-桥梁结构地震相互作用分析的合理数值模型与简化分析方法。鉴于此,直接针对振动台试验,基于非线性文克尔地基梁模型,考虑桩周参振土的质量惯性力、上部结构的惯性力、土体辐射阻尼等效应,建立了液化场地桩-土-桥梁结构地震相互作用的p-y曲线分析模型,并给出相应的简化方法。针对振动台试验进行了0.1g El Centro波输入下的分析,验证了桩-土地震相互作用分析方法的正确性,并且推荐了计算参数的合理选取方法,可用于液化场地桩-土地震相互作用的分析。提出的液化场地桩-土地震相互作用p-y曲线简化分析方法,为实际桥梁桩基抗震设计与分析提供一定参考。
基金Project(51378050) supported by the National Natural Science Foundation of ChinaProject(B13002) supported by the “111” Project,China+2 种基金Project (8192035) supported by the Beijing Municipal Natural Science Foundation,ChinaProject(P2019G002) supported by the Science and Technology Research and Development Program of China RailwayProject(2019YJ193) supported by the State Key Laboratory for Track Technology of High-speed Railway,China。
文摘Bridges crossing active faults are more likely to suffer serious damage or even collapse due to the wreck capabilities of near-fault pulses and surface ruptures under earthquakes.Taking a high-speed railway simply-supported girder bridge with eight spans crossing an active strike-slip fault as the research object,a refined coupling dynamic model of the high-speed train-CRTS III slab ballastless track-bridge system was established based on ABAQUS.The rationality of the established model was thoroughly discussed.The horizontal ground motions in a fault rupture zone were simulated and transient dynamic analyses of the high-speed train-track-bridge coupling system under 3-dimensional seismic excitations were subsequently performed.The safe running speed limits of a high-speed train under different earthquake levels(frequent occurrence,design and rare occurrence)were assessed based on wheel-rail dynamic(lateral wheel-rail force,derailment coefficient and wheel-load reduction rate)and rail deformation(rail dislocation,parallel turning angle and turning angle)indicators.Parameter optimization was then investigated in terms of the rail fastener stiffness and isolation layer friction coefficient.Results of the wheel-rail dynamic indicators demonstrate the safe running speed limits for the high-speed train to be approximately 200 km/h and 80 km/h under frequent and design earthquakes,while the train is unable to run safely under rare earthquakes.In addition,the rail deformations under frequent,design and rare earthquakes meet the safe running requirements of the high-speed train for the speeds of 250,100 and 50 km/h,respectively.The speed limits determined for the wheel-rail dynamic indicators are lower due to the complex coupling effect of the train-track-bridge system under track irregularity.The running safety of the train was improved by increasing the fastener stiffness and isolation layer friction coefficient.At the rail fastener lateral stiffness of 60 kN/mm and isolation layer friction coefficients of 0.9 and 0.8,respectively,the safe running speed limits of the high-speed train increased to 250 km/h and 100 km/h under frequent and design earthquakes,respectively.
基金Project(Y2007F48) supported by the Natural Science Foundation of Shandong Province,ChinaProject(SDTS20080422) supported by the Specialized Development Foundation for Taishan Scholars of Shandong Province, China Project(SDVS20090525) supported by the Specialized Foundation for Domestic Visiting Scholars of Shandong Province,China
文摘In order to analyze the seismic response characteristics of pile-supported structure,a computational model considering pile-soil-structure interaction effect was established by finite element method.Then,numerical implementation was made in time domain.At the same time,a simplified approximation for seismic response analysis of pile-soil-structure system was briefly presented.Furthermore,comparative study was performed for an engineering example.Through comparative analysis,it is shown that the results obtained by the simplified method well agree with those achieved by the finite element method.These results show that spectrum characteristics and intensity of input earthquakes are two important factors that can notablely influence the seismic response characteristics of superstructure.When the input ground motion acceleration amplitude gradually increases from 1 to 4 m/s2,the acceleration of pier top will increase,but it will not be simply proportional to the increase of input acceleration amplitude.