In order to realize on-line real-time measurement of dynamic and time-sharing neutron spectrum of HL-2A,a tokamak fusion neutron spectrometer based on PXI bus was developed.It consists of electronics system and eight ...In order to realize on-line real-time measurement of dynamic and time-sharing neutron spectrum of HL-2A,a tokamak fusion neutron spectrometer based on PXI bus was developed.It consists of electronics system and eight thermal neutron detectors,namely SP9~3He proportional counter,embedded in eight polyethylene spheres in different diameters.Response function of the eight polyethylene spheres was the key to calculate the neutron spectrum accurately.In this paper,response function of the eight polyethylene spheres is simulated by adopting Geant4 code,and neutron counts from an^(241)Am-Be neutron source are measured by the eight detectors.The calculated spectrum of the Am-Be neutron is accurate in 0-2 MeV region,and is similar to the theoretical spectrum.The tokamak fusion neutron spectrometer was used in HL-2A device to monitor the dynamic neutron spectrum of HL-2A on-line and real-time.展开更多
In order to realize the on-line real-time measurement of neutron spectrum of ITER fusion,this paper presents a multi-sphere spectrometer system which consists of eight thermal neutron detectors,namely SP9 3He proporti...In order to realize the on-line real-time measurement of neutron spectrum of ITER fusion,this paper presents a multi-sphere spectrometer system which consists of eight thermal neutron detectors,namely SP9 3He proportional counter,embedded in eight different diameter polyethylene spheres.The response function of eight polyethylene spheres of multi-sphere neutron spectrometer was calculated after the simulation of the neutron transport processes in multi-sphere spectrometer by adopting software Geant4.The peak of the response function is in the low energy region for smaller diameter polyethylene sphere.As the polyethylene sphere diameter increased,the peak of the response function moves to the high energy region.The experimental calibration adopts 241Am-Be neutron source.The relative error between normalized data of experiment 4πsolid angle counts and normalized data of simulated detection efficiency of 4in to 8in polyethylene sphere is from 1.152%to 12.222%.The experimental results verify the response function of the simulation.All these results provide a theoretical and experimental basis for solving the on-line real-time neutron spectrum of ITER fusion.展开更多
基金Supported by Ministry of science and technology major projects(No.2013GB104003)National Natural Science Foundation of China(No.11375195)Ministry of Education and Youth Innovation Fund(No.WK2030040037)
文摘In order to realize on-line real-time measurement of dynamic and time-sharing neutron spectrum of HL-2A,a tokamak fusion neutron spectrometer based on PXI bus was developed.It consists of electronics system and eight thermal neutron detectors,namely SP9~3He proportional counter,embedded in eight polyethylene spheres in different diameters.Response function of the eight polyethylene spheres was the key to calculate the neutron spectrum accurately.In this paper,response function of the eight polyethylene spheres is simulated by adopting Geant4 code,and neutron counts from an^(241)Am-Be neutron source are measured by the eight detectors.The calculated spectrum of the Am-Be neutron is accurate in 0-2 MeV region,and is similar to the theoretical spectrum.The tokamak fusion neutron spectrometer was used in HL-2A device to monitor the dynamic neutron spectrum of HL-2A on-line and real-time.
基金Supported by ITER Plan National Major Project 2008GB109000
文摘In order to realize the on-line real-time measurement of neutron spectrum of ITER fusion,this paper presents a multi-sphere spectrometer system which consists of eight thermal neutron detectors,namely SP9 3He proportional counter,embedded in eight different diameter polyethylene spheres.The response function of eight polyethylene spheres of multi-sphere neutron spectrometer was calculated after the simulation of the neutron transport processes in multi-sphere spectrometer by adopting software Geant4.The peak of the response function is in the low energy region for smaller diameter polyethylene sphere.As the polyethylene sphere diameter increased,the peak of the response function moves to the high energy region.The experimental calibration adopts 241Am-Be neutron source.The relative error between normalized data of experiment 4πsolid angle counts and normalized data of simulated detection efficiency of 4in to 8in polyethylene sphere is from 1.152%to 12.222%.The experimental results verify the response function of the simulation.All these results provide a theoretical and experimental basis for solving the on-line real-time neutron spectrum of ITER fusion.