采用反相离子对色谱-蒸发光散射检测法,研究了阿仑膦酸钠及相关物质的色谱分离。选择的色谱条件是:固定相为Intersil C8(150×4.6 mm i.d.,5μm)柱,以52mmol.L-1正戊胺水溶液(用乙酸调节pH至7.0)-甲醇(98∶2,V/V)为流动相,流速为1.0...采用反相离子对色谱-蒸发光散射检测法,研究了阿仑膦酸钠及相关物质的色谱分离。选择的色谱条件是:固定相为Intersil C8(150×4.6 mm i.d.,5μm)柱,以52mmol.L-1正戊胺水溶液(用乙酸调节pH至7.0)-甲醇(98∶2,V/V)为流动相,流速为1.0 mL.min-1,柱温为室温。在该色谱条件下,阿仑膦酸钠与其有关物质(包括合成过程中残余的原料4-氨基丁酸、亚磷酸及分解产物磷酸盐)分离良好。本法简便、快速,为阿仑膦酸钠的常规分析及质量控制提供了一种可靠而有效的手段。展开更多
A novel reserved\|phase ion\|pair liquid chromatographic method using hexadecyltrimethylammonium bromide(HTMAB) as an ion\|pair reagent for separating the complexes of metal and 8\|hydroxyquinoline\|5\|sulphonic aci...A novel reserved\|phase ion\|pair liquid chromatographic method using hexadecyltrimethylammonium bromide(HTMAB) as an ion\|pair reagent for separating the complexes of metal and 8\|hydroxyquinoline\|5\|sulphonic acid(HQS) coupled with on\|line fluorescence detection has been developed. The chromatographic behavior of metal\|HQS complexes in the proposed system was systematically investigated.When the C\-\{18\} column modified by HTMAB and the suitable mobile phase coupled with fluorescence detection(\%λ\%\-\{ex\}=388 nm; \%λ\%\-\{em\}=518 nm) were employed, the detection limit of cadmium is 7.72 ng/mL with an injection volume of 20 μL, and the linear range of calibration curve for cadmium is 50\800 ng/mL. It was successfully applied to determination of bio\|available cadmium in polluted soils of China. Moreover, the possible species of Cd\|HQS on the column has been investigated by log\|log plot analysis.展开更多
文摘采用反相离子对色谱-蒸发光散射检测法,研究了阿仑膦酸钠及相关物质的色谱分离。选择的色谱条件是:固定相为Intersil C8(150×4.6 mm i.d.,5μm)柱,以52mmol.L-1正戊胺水溶液(用乙酸调节pH至7.0)-甲醇(98∶2,V/V)为流动相,流速为1.0 mL.min-1,柱温为室温。在该色谱条件下,阿仑膦酸钠与其有关物质(包括合成过程中残余的原料4-氨基丁酸、亚磷酸及分解产物磷酸盐)分离良好。本法简便、快速,为阿仑膦酸钠的常规分析及质量控制提供了一种可靠而有效的手段。
文摘A novel reserved\|phase ion\|pair liquid chromatographic method using hexadecyltrimethylammonium bromide(HTMAB) as an ion\|pair reagent for separating the complexes of metal and 8\|hydroxyquinoline\|5\|sulphonic acid(HQS) coupled with on\|line fluorescence detection has been developed. The chromatographic behavior of metal\|HQS complexes in the proposed system was systematically investigated.When the C\-\{18\} column modified by HTMAB and the suitable mobile phase coupled with fluorescence detection(\%λ\%\-\{ex\}=388 nm; \%λ\%\-\{em\}=518 nm) were employed, the detection limit of cadmium is 7.72 ng/mL with an injection volume of 20 μL, and the linear range of calibration curve for cadmium is 50\800 ng/mL. It was successfully applied to determination of bio\|available cadmium in polluted soils of China. Moreover, the possible species of Cd\|HQS on the column has been investigated by log\|log plot analysis.