期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
DT型管状接头的参数应力分析
1
作者 陈铁云 张惠元 《上海交通大学学报》 EI CAS CSCD 北大核心 1994年第6期11-18,共8页
本文用半解析法对在轴力与面外弯矩作用下的19只空间DT型管接头的应力分布进行计算,用以确定DT接头的几何参数对接头局部应力的影响.将这些计算结果与T型接头的计算结果进行比较后,便可将T型接头的应力参数公式通过修正系数... 本文用半解析法对在轴力与面外弯矩作用下的19只空间DT型管接头的应力分布进行计算,用以确定DT接头的几何参数对接头局部应力的影响.将这些计算结果与T型接头的计算结果进行比较后,便可将T型接头的应力参数公式通过修正系数求得DT型接头应力集中系数的参数公式.最后讨论了DT型接头的刚度效应与载荷互作用效应. 展开更多
关键词 管状接头 参数应力分析 刚度效应
在线阅读 下载PDF
Stress redistribution of simply supported reinforced concrete beams under fire conditions 被引量:4
2
作者 DING Fa-xing LI Zhe YU Zhi-wu 《Journal of Central South University》 SCIE EI CAS CSCD 2018年第9期2093-2106,共14页
This study presents experimental and numerical investigations of simply supported steel reinforced concrete(RC)beams under fire.The temperature field of cross sections,the vertical deflection at mid-span,and specifica... This study presents experimental and numerical investigations of simply supported steel reinforced concrete(RC)beams under fire.The temperature field of cross sections,the vertical deflection at mid-span,and specifically the axial expansion displacement at beam-ends were measured during the fire tests.A novel finite element(FE)model of a RC beam under fire was developed,in which the water loss in the heat transfer analysis and the concrete transient strain in the mechanical analysis were considered.Based on the validated FE model proposed in this study,parametric studies were conducted to investigate the effects of the beam type,the protective layer thickness,and the load ratio on the thermal and mechanical behavior of simply supported RC beams.It was found that greater fire resistance and fire performance of girder beams in comparison to secondary beams contributed to the non-structural reinforcements,which effectively compensated for the reduced tensile capacities of structural reinforcements because of the degradation of the material properties.In addition,the history of normal stress distributions of concrete under fire can be divided into three phases:expansion,stress redistribution and plateau phases. 展开更多
关键词 reinforced concrete beam transient strain fire condition parametric analysis stress redistribution
在线阅读 下载PDF
Evaluation of soil arching effect due to partially mobilized shear stress in piled and geosynthetic-reinforced embankment
3
作者 LV Wei-hua WU Tao +1 位作者 GU Fan GAO Lei 《Journal of Central South University》 SCIE EI CAS CSCD 2020年第7期2094-2112,共19页
In piled and geosynthetic-reinforced(PGR) embankment, the arching behavior determines the overburden load on piles and subsoils. Placement of geosynthetic is effective in reducing the relative displacement between pil... In piled and geosynthetic-reinforced(PGR) embankment, the arching behavior determines the overburden load on piles and subsoils. Placement of geosynthetic is effective in reducing the relative displacement between pile and subsoil. When the mobilized shear stress is less than the shear strength, partially developed arching will occur. Consequently, existing analytical methods, adopting the ultimate shear strength failure criterion, need to be improved. This study developed a simplified 2 D analytical method, which is based on the developing arching effect, to evaluate the load redistribution of the PGR embankment. Then, the influences of embankment height and internal friction angle, subsoil depth, ratio of pile cap width to pile clear spacing(RPC) and geosynthetic tensile stiffness on the critical height ratio, stress concentration ratio, soil arching ratio, geosynthetic tension and axial strain were investigated. This study suggests that a RPC of 1:1.0 and a one-way of single-layer geosynthetic tensile stiffness of 2000 kN/m should be considered as the sensitivity thresholds for the PGR embankment. 展开更多
关键词 PILE GEOSYNTHETIC arching effect mobilized shear stress parametric analysis
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部