期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
非体外循环冠状动脉旁路移植术对右心室血流动力学的影响 被引量:1
1
作者 王辉山 汪曾炜 +5 位作者 朱洪玉 姜辉 陶登顺 王镇龙 孙承函 张铁铮 《中国微创外科杂志》 CSCD 2005年第4期307-309,共3页
目的应用连续心排血量测定的方法,观察在进行非体外循环冠状动脉旁路移植术(OPCABG)中右心功能的变化. 方法冠状动脉粥硬化性心脏病178例,均为2~3支血管病变需行冠状动脉旁路移植术.术前心功能Ⅱ级72例,Ⅲ级84例,Ⅳ级22例.左心室射血分... 目的应用连续心排血量测定的方法,观察在进行非体外循环冠状动脉旁路移植术(OPCABG)中右心功能的变化. 方法冠状动脉粥硬化性心脏病178例,均为2~3支血管病变需行冠状动脉旁路移植术.术前心功能Ⅱ级72例,Ⅲ级84例,Ⅳ级22例.左心室射血分数0.35~0.82,平均搭桥数3.3根.所有病人均行Swan-Ganz漂浮导管,用连续心输出量监测仪连续监测血流动力学指标,包括心率(HR),平均动脉压(MAP),中心静脉压(CVP),平均肺动脉压(MPAP),右房压(RAP),肺毛细血管楔压(PCWP),心输出量(CO),心脏指数(CI),每搏容量指数(SVI),体循环阻力指数(SVRI),肺循环阻力指数(PVRI),混合静脉血饱和度(SvO2),右室射血分数(RVEF),右室收缩末容量(RVESV),右室舒张末容量(RVEDV),右室收缩末容量指数(RVESVI),右室舒张末容量指数(RVEDVI).设定时间点观察血流动力学指标:麻醉诱导后血流动力学稳定后,准备搬动心脏前(T1),吻合前降支前(T2),吻合回旋支或对角支前(T3),吻合右冠状动脉或后降支前(T4),心脏回位后,关胸前(T5).结果 4例死亡,其中2例为术前急性心肌梗死急诊手术,术后3天死于严重低心排血量综合征,1例术后7天死于严重呼吸衰竭,1例于术后4天死于急性肺栓塞.与T1相比,T2时,MPAP,PCWP,RAP和PVRI明显增加而SvO2明显降低;T3时,血流动力学变化明显,MPAP,PCWP,RAP和PVRI明显增加,SvO2明显降低,CI,SVI,RVEF明显下降,SVRI明显增加;T4时,HR,RAP明显增加而SvO2明显降低;T5时未恢复正常水平. 结论在进行纯缘支吻合时,右心功能有所下降,主要是CI及RVEF有明显的变化,而在前降支及右冠状动脉的吻合时,对右心血流动力学影响不大,因此,在OPCABG中监护右心功能具有重要意义,尤其是对右心功能受到损害的患者. 展开更多
关键词 非体外循环 冠状动脉路移植术 右心室 血流动力学
在线阅读 下载PDF
MR IMAGING OF CORONARY ARTERY BYPASS GRAFT:A PRELIMINARY STUDY
2
作者 朱杰敏 张竹花 刘玉清 《Chinese Medical Sciences Journal》 CAS CSCD 2000年第2期67-72,共6页
Objective. To make a preliminary investigation of the patency and function of coronary artery bypass grafts(CABG) by magnetic resonance(MR) images and to establish a suitable method for followup study after CABG opera... Objective. To make a preliminary investigation of the patency and function of coronary artery bypass grafts(CABG) by magnetic resonance(MR) images and to establish a suitable method for followup study after CABG operation among Chinese. Methods. MR imaging was performed with a Toshiba 15T unit in 27 patients with 74 grafts. All patients were examined with a breathhold ECGgated twodimensional fast field echo (FFE) sequence to evaluate the patency of bypass grafts, among them 16 patients with 42 grafts were further examined with a phase shift magnetic resonance angiography flow (PSMRAflow) sequence to evaluate the grafts patency as well as the flow velocity and flow volume vs. time. Results. The results showed that 66 of the 74 grafts in the patients of the present series studied with FFE were patent with a patency rate of 892% The results evaluated both with FFE and PSMRAflow remained the same except that two grafts were patent with FFE and the results with PSMRAflow were uncertain. Diastolic perfusion pattern curves were found in 25 of the 32 grafts in patients of the present series. Comparing the flow curves of the grafted left internal mammary artery with those of the native right internal mammary artery in 7 patients, the systolic peak velocity value(SPV) of the grafted arteries was significantly lower than that of the ungrafted ones, whereas the diastolic peak velocity value(DPV) and the ratio of DPV to SPV were significantly greater than that of the ungrafed ones. Conclusion. The FFE and PSMRAflow sequences were efficient in evaluating patency and obtaining the curves of flow velocity and volume of the bypass grafts. Therefore, they may offer a noninvasive screening method for followup study in patients after CABG surgery, although its accuracy should be further evaluated in more patients and comparatively studied with other methods. 展开更多
关键词 coronary artery bypass magnetic resonance imaging flow
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部