In this paper,in order to achieve the output signal processing of cavity beam position monitor(CBPM),we develop a digital intermediate frequency receiver architecture based signal processing system,which consists of r...In this paper,in order to achieve the output signal processing of cavity beam position monitor(CBPM),we develop a digital intermediate frequency receiver architecture based signal processing system,which consists of radio frequency(RF) front end and high speed data acquisition board.The beam position resolution in the CBPM signal processing system is superior to 1μm.Two signal processing algorithms,fast Fourier transform(FFT) and digital down converter(DDC),are evaluated offline using MATLAB platform,and both can be used to achieve,the CW input signal,position resolutions of 0.31μm and 0.10μm at -16 dBm.The DDC algorithm for its good compatibility is downloaded into the FPGA to realize online measurement,reaching the position resolution of 0.49μm due to truncation error.The whole system works well and the performance meets design target.展开更多
In order to pursue high-precision beam position measurements for free-electron laser facilities, a cavity beam position monitor(CBPM) is employed to measure the transverse position that can meet the requirement of pos...In order to pursue high-precision beam position measurements for free-electron laser facilities, a cavity beam position monitor(CBPM) is employed to measure the transverse position that can meet the requirement of position resolution at a sub-micrometer or even nanometer scale. However, for the pill-box cavity BPM, crosstalk between the cavities will have an effect on the accurate measurement of beam position. To reduce the effect of crosstalk on CBPM performance and ease the measurement of the isolation between the cavities, the cavities with a slight difference in resonant frequency were designed and applied in the Dalian coherent light source and Shanghai soft X-ray free-electron laser facilities. Furthermore, two methods, the principal component analysis method and the method of harmonic analysis, are proposed in this paper to evaluate the crosstalk. The results demonstrate that the two methods are feasible in evaluating the crosstalk between the cavities.展开更多
A fully digital beam position monitoring system(DBPM) has been designed for SSRF(Shanghai Synchrotron Radiation Facility). As analog-to-digital converter(ADC) is a crucial part in the DBPM system, the sampling methods...A fully digital beam position monitoring system(DBPM) has been designed for SSRF(Shanghai Synchrotron Radiation Facility). As analog-to-digital converter(ADC) is a crucial part in the DBPM system, the sampling methods should be studied to achieve optimum performance. Different sampling modes were used and compared through tests. Long term variation among four sampling channels, which would introduce errors in beam position measurement, is investigated. An interleaved distribution scheme was designed to address this issue. To evaluate the sampling methods, in-beam tests were conducted in SSRF. Test results indicate that with proper sampling methods, a turn-by-turn(TBT) position resolution better than 1 μm is achieved, and the slow-acquisition(SA) position resolution is improved from 4.28 μm to 0.17 μm.展开更多
基金Supported by National Natural Science Foundaion of China(No.11075198)
文摘In this paper,in order to achieve the output signal processing of cavity beam position monitor(CBPM),we develop a digital intermediate frequency receiver architecture based signal processing system,which consists of radio frequency(RF) front end and high speed data acquisition board.The beam position resolution in the CBPM signal processing system is superior to 1μm.Two signal processing algorithms,fast Fourier transform(FFT) and digital down converter(DDC),are evaluated offline using MATLAB platform,and both can be used to achieve,the CW input signal,position resolutions of 0.31μm and 0.10μm at -16 dBm.The DDC algorithm for its good compatibility is downloaded into the FPGA to realize online measurement,reaching the position resolution of 0.49μm due to truncation error.The whole system works well and the performance meets design target.
基金partially supported by the National Natural Science Foundation of China(Nos.11575282 and 11305253)
文摘In order to pursue high-precision beam position measurements for free-electron laser facilities, a cavity beam position monitor(CBPM) is employed to measure the transverse position that can meet the requirement of position resolution at a sub-micrometer or even nanometer scale. However, for the pill-box cavity BPM, crosstalk between the cavities will have an effect on the accurate measurement of beam position. To reduce the effect of crosstalk on CBPM performance and ease the measurement of the isolation between the cavities, the cavities with a slight difference in resonant frequency were designed and applied in the Dalian coherent light source and Shanghai soft X-ray free-electron laser facilities. Furthermore, two methods, the principal component analysis method and the method of harmonic analysis, are proposed in this paper to evaluate the crosstalk. The results demonstrate that the two methods are feasible in evaluating the crosstalk between the cavities.
基金Supported by the Knowledge Innovation Program of the Chinese Academy of Sciences(No.KJCX2-YW-N27)National Natural Science Foundation of China(Nos.11205153 and 11175176)
文摘A fully digital beam position monitoring system(DBPM) has been designed for SSRF(Shanghai Synchrotron Radiation Facility). As analog-to-digital converter(ADC) is a crucial part in the DBPM system, the sampling methods should be studied to achieve optimum performance. Different sampling modes were used and compared through tests. Long term variation among four sampling channels, which would introduce errors in beam position measurement, is investigated. An interleaved distribution scheme was designed to address this issue. To evaluate the sampling methods, in-beam tests were conducted in SSRF. Test results indicate that with proper sampling methods, a turn-by-turn(TBT) position resolution better than 1 μm is achieved, and the slow-acquisition(SA) position resolution is improved from 4.28 μm to 0.17 μm.