期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
是“题材狭窄”,还是对题材的拓宽──论明代散文大家归有光的创作
1
作者 马鸿盛 《国际安全研究》 CSSCI 1996年第4期24-30,共7页
一些论著多认为归有光的散文“题材狭窄”,“缺乏深广的现实内容”。其实,归有光散文创作体裁多样,题材涉及面相当广泛;其回忆往事,悼念亲人之抒情记叙小品文恰恰是对我国传统散文题材领域的创新、拓宽和发展;此外,归氏在文艺理... 一些论著多认为归有光的散文“题材狭窄”,“缺乏深广的现实内容”。其实,归有光散文创作体裁多样,题材涉及面相当广泛;其回忆往事,悼念亲人之抒情记叙小品文恰恰是对我国传统散文题材领域的创新、拓宽和发展;此外,归氏在文艺理论方面也颇有建树。 展开更多
关键词 归有光 散文 题材 “狭窄” 拓宽与创新
在线阅读 下载PDF
0D-1D coupling model and 3D fluid-structure interaction model based on coronary CT angiography for displaying hemodynamic characteristics of coronary artery stenosis
2
作者 LIU Shanfeng LU Xiaochen +1 位作者 TIAN Hao WU Huiqun 《中国医学影像技术》 CSCD 北大核心 2024年第8期1236-1241,共6页
Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Base... Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Based on CCTA data of the stenosed left anterior descending branch(LAD)in a patient with coronary heart disease,an 0D-1D coupling model and 3D FSI model were built,respectively.Then hemodynamic characteristic indexes,including the pressure,flow velocity and wall shear stress(WSS)were obtained in every 0.01 s during 1 s at 5 sampling points(i.e.sampling point 1—5)using these 2 models,respectively,and the consistencies of the results between models were evaluated with Spearman correlation coefficient r s.Results The time consuming for construction of 0D-1D coupling model and 3D FSI model was 0.033 min and 704 min,respectively.Both models showed basically distribution of the pressure,flow velocity and WSS of the stenosed LAD.For more details,the pressure at the stenosed segment of LAD and the proximal segment of stenosis were both higher,which gradually decreased at the distal segment of stenosis,and the flow velocity at the proximal segment of stenosis was in a relatively slow and uniform condition,with significantly increased flow velocity and WSS at the stenosed segment.Compared with 3D FSI model,0D-1D vascular coupling model was relatively unrefined and lack of distal flow lines when displaying blood flow velocity.For sampling point 2 at the stenosed segment of LAD,no significant consistency for pressure between 2 models was found(P=0.118),but strong consistency for the flow velocity and WSS(r s=0.730,0.807,both P<0.05).The consistencies of pressure,flow velocity and WSS between 2 models at the proximal and distal segment of stenosis,i.e.1,3—5 sampling points were week to moderate(r s=0.237—0.669,all P<0.05).Conclusion 0D-1D coupling model exhibited outstanding computational efficiency and might provide relatively reasonable results,while 3D FSI model showed higher accuracy for details and streamline when simulating LAD stenosis. 展开更多
关键词 coronary stenosis HEMODYNAMICS coronary angiography tomography X-ray computed
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部