期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Numerical simulation and analysis of solid-liquid two-phase threedimensional unsteady flow in centrifugal slurry pump 被引量:17
1
作者 吴波 汪西力 +1 位作者 LIU Hui 徐海良 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第8期3008-3016,共9页
Based on RNG k-ε turbulence model and sliding grid technique, solid-liquid two-phase three-dimensional(3-D) unsteady turbulence of full passage in slurry pump was simulated by means of Fluent software. The effects of... Based on RNG k-ε turbulence model and sliding grid technique, solid-liquid two-phase three-dimensional(3-D) unsteady turbulence of full passage in slurry pump was simulated by means of Fluent software. The effects of unsteady flow characteristics on solid-liquid two-phase flow and pump performance were researched under design condition. The results show that clocking effect has a significant influence on the flow in pump, and the fluctuation of flow velocity and pressure is obvious, particularly near the volute tongue, at the position of small sections of volute and within diffuser. Clocking effect has a more influence on liquid-phase than on solid-phase, and the wake-jet structure of relative velocity of solid-phase is less obvious than liquid-phase near the volute tongue and the impeller passage outlet. The fluctuation of relative velocity of solid-phase flow is 7.6% smaller than liquid-phase flow at the impeller outlet on circular path. Head and radial forces of the impeller are 8.1% and 85.7% of fluctuation, respectively. The results provide a theoretical basis for further research for turbulence, improving efficient, reducing the hydraulic losses and wear. Finally, field tests were carried out to verify the operation and wear of slurry pump. 展开更多
关键词 slurry pump solid-liquid two-phase flow unsteady flow 3-D full passage numerical simulation
在线阅读 下载PDF
Force and Flow Structure of an Airfoil Performing Some Unsteady Motions at Small Reynolds Number 被引量:9
2
作者 Sun Mao Hossein Hamdani (Institute of Fluid Mechanics,Beijing University of Aeronautics & Astronautics) 《空气动力学学报》 CSCD 北大核心 2000年第z1期96-102,共7页
关键词 Flow Re Force and Flow Structure of an Airfoil Performing Some unsteady Motions at Small Reynolds Number
在线阅读 下载PDF
Computational fluid dynamics of left ventricular assist device under unsteady flow
3
作者 BUMRUNGPETCH J. TAN A.C. 《排灌机械工程学报》 EI CSCD 北大核心 2016年第2期93-98,共6页
Left ventricular assist device( LVAD) in this study is a mechanical tool that is used to support blood flow in the patient with heart disease. It supports left ventricle by building up the pressure to the pump outlet ... Left ventricular assist device( LVAD) in this study is a mechanical tool that is used to support blood flow in the patient with heart disease. It supports left ventricle by building up the pressure to the pump outlet connected to the aorta. This pump was designed based on the magnetic driven centrifugal pump with a unique small washout hole constructed inside the impeller to generate the washout flow passage to prevent the stagnation at the region underneath and around the rotor. Computational fluid dynamics( CFD) was adopted in this study to assess the performance and optimize the design to avoid recirculation and high shear stress which is the main cause of stagnation and blood damage. Transient simulation was used for this study due to the asymmetric design of the washout hole and the complication of the bottom support of the impeller that has a risk of thrombosis,also,it was used to predict the variation of hydraulic performance caused by the rotation of the impeller and pulsed flow at the pump inlet. The simulation results show no excessive stress and no recirculation observed within the computational domain; in addition,the research result also provides information for further optimization and development to the pump. 展开更多
关键词 heart pump left ventricular assist device computational fluid dynamics unsteady flow
在线阅读 下载PDF
A numerical simulation of unsteady flow in small diameter helical grafts
4
作者 Tinghui Zheng2,Yubo Fan1,Weizhong Wang2,Wentao Jiang2,Xiaoyan Deng1(1.School of Biological Science and Medical Engineering,Beihang University,Beijing,China 2.Department of Applied Mechanics,Sichuan University,Chengdu,Chin 《医用生物力学》 EI CAS CSCD 2009年第S1期40-41,共2页
The application of small diameter arterial grafts is limited due to the fact of relatively poor long-time patency which is caused by thrombosis formation in the short term and intimal hyperplasia(IH) in the medium and... The application of small diameter arterial grafts is limited due to the fact of relatively poor long-time patency which is caused by thrombosis formation in the short term and intimal hyperplasia(IH) in the medium and long term.Thrombosis,obstructing the flow of blood 展开更多
关键词 A numerical simulation of unsteady flow in small diameter helical grafts FLOW
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部