The transform fault is essentially a displacement fault whose terminal part is adjusted by other tectonic types, its displacement component is absorbed by other structures intersected with it by high angles or meet at...The transform fault is essentially a displacement fault whose terminal part is adjusted by other tectonic types, its displacement component is absorbed by other structures intersected with it by high angles or meet at right angles. The main elements of transform fault are the sleep\|dipping displacement faults and the adjusted structures intersected with it at high angles. According to the combination of tectonic features formed by its two ends of displacement fault and the structures intersected with it, the transform fault can be divided into three types, including the adjusted transform fault of extensional normal fault, the adjusted transform fault of compressive fold and thrust fault, and the compound transform fault. The transform fault is different from the displacement fault, its horizontal displacement may be increased or decreased or not be changed at all as the time of fault movement extended, but for parallel displacement the dislocation will be increased. Therefore, the study of transform fault is very important for the recognition of long time disputed displacement components of huge displacement fault. The traditional Altyn fault is the adjusting fault of the compression deformation of the Western Kunlun and Northern Qilian mountains of the northern margin of the Tibetan Plateau since Cenozoic.展开更多
>Transformer faults are quite complicated phenomena and can occur due to a variety of reasons.There have been several methods for transformer fault synthetic diagnosis,but each of them has its own limitations in re...>Transformer faults are quite complicated phenomena and can occur due to a variety of reasons.There have been several methods for transformer fault synthetic diagnosis,but each of them has its own limitations in real fault diagnosis applications.In order to overcome those shortcomings in the existing methods,a new transformer fault diagnosis method based on a wavelet neural network optimized by adaptive genetic algorithm(AGA)and an improved D-S evidence theory fusion technique is proposed in this paper.The proposed method combines the oil chromatogram data and the off-line electrical test data of transformers to carry out fault diagnosis.Based on the fusion mechanism of D-S evidence theory,the comprehensive reliability of evidence is constructed by considering the evidence importance,the outputs of the neural network and the expert experience.The new method increases the objectivity of the basic probability assignment(BPA)and reduces the basic probability assigned for uncertain and unimportant information.The case study results of using the proposed method show that it has a good performance of fault diagnosis for transformers.展开更多
基金theNationalNaturalScienceFoundationofChina (No .4 980 2 0 19)
文摘The transform fault is essentially a displacement fault whose terminal part is adjusted by other tectonic types, its displacement component is absorbed by other structures intersected with it by high angles or meet at right angles. The main elements of transform fault are the sleep\|dipping displacement faults and the adjusted structures intersected with it at high angles. According to the combination of tectonic features formed by its two ends of displacement fault and the structures intersected with it, the transform fault can be divided into three types, including the adjusted transform fault of extensional normal fault, the adjusted transform fault of compressive fold and thrust fault, and the compound transform fault. The transform fault is different from the displacement fault, its horizontal displacement may be increased or decreased or not be changed at all as the time of fault movement extended, but for parallel displacement the dislocation will be increased. Therefore, the study of transform fault is very important for the recognition of long time disputed displacement components of huge displacement fault. The traditional Altyn fault is the adjusting fault of the compression deformation of the Western Kunlun and Northern Qilian mountains of the northern margin of the Tibetan Plateau since Cenozoic.
基金Project Supported by National Natural Science Foundation of China ( 50777069 ).
文摘>Transformer faults are quite complicated phenomena and can occur due to a variety of reasons.There have been several methods for transformer fault synthetic diagnosis,but each of them has its own limitations in real fault diagnosis applications.In order to overcome those shortcomings in the existing methods,a new transformer fault diagnosis method based on a wavelet neural network optimized by adaptive genetic algorithm(AGA)and an improved D-S evidence theory fusion technique is proposed in this paper.The proposed method combines the oil chromatogram data and the off-line electrical test data of transformers to carry out fault diagnosis.Based on the fusion mechanism of D-S evidence theory,the comprehensive reliability of evidence is constructed by considering the evidence importance,the outputs of the neural network and the expert experience.The new method increases the objectivity of the basic probability assignment(BPA)and reduces the basic probability assigned for uncertain and unimportant information.The case study results of using the proposed method show that it has a good performance of fault diagnosis for transformers.