期刊文献+
共找到14,918篇文章
< 1 2 250 >
每页显示 20 50 100
Research process on radioactive^(18)F-labelled chemical agents as positron emission tomography imaging probes for tumour detection
1
作者 WU Rui ZHANG Yankun +2 位作者 LU Jiufu ZHANG Pengfei WANG Yang 《无机化学学报》 北大核心 2025年第9期1702-1718,共17页
Malignant tumours always threaten human health.For tumour diagnosis,positron emission tomography(PET)is the most sensitive and advanced imaging technique by radiotracers,such as radioactive^(18)F,^(11)C,^(64)Cu,^(68)G... Malignant tumours always threaten human health.For tumour diagnosis,positron emission tomography(PET)is the most sensitive and advanced imaging technique by radiotracers,such as radioactive^(18)F,^(11)C,^(64)Cu,^(68)Ga,and^(89)Zr.Among the radiotracers,the radioactive^(18)F-labelled chemical agent as PET probes plays a predominant role in monitoring,detecting,treating,and predicting tumours due to its perfect half-life.In this paper,the^(18)F-labelled chemical materials as PET probes are systematically summarized.First,we introduce various radionuclides of PET and elaborate on the mechanism of PET imaging.It highlights the^(18)F-labelled chemical agents used as PET probes,including[^(18)F]-2-deoxy-2-[^(18)F]fluoro-D-glucose([^(18)F]-FDG),^(18)F-labelled amino acids,^(18)F-labelled nucleic acids,^(18)F-labelled receptors,^(18)F-labelled reporter genes,and^(18)F-labelled hypoxia agents.In addition,some PET probes with metal as a supplementary element are introduced briefly.Meanwhile,the^(18)F-labelled nanoparticles for the PET probe and the multi-modality imaging probe are summarized in detail.The approach and strategies for the fabrication of^(18)F-labelled PET probes are also described briefly.The future development of the PET probe is also prospected.The development and application of^(18)F-labelled PET probes will expand our knowledge and shed light on the diagnosis and theranostics of tumours. 展开更多
关键词 ^(18)F RADIOACTIVE IMAGING positron emission tomography LABELLED TUMOUR
在线阅读 下载PDF
Computed tomography versus transthoracic echocardiography in the detection of complex congenial heart diseases in china:a meta-analysis
2
作者 畅智慧 LIN Kun +3 位作者 DU Xiao-li YIN Xiao-li LU Zhao 刘兆玉 《放射学实践》 2012年第11期1168-1173,共6页
Objective:To perform a meta-analysis to evaluate the diagnostic performance of computed tomography(CT) and transthoracic echocardiography(TTE) in complex congenital heart diseases(CHD) in China.Methods:MEDLINE,Cochran... Objective:To perform a meta-analysis to evaluate the diagnostic performance of computed tomography(CT) and transthoracic echocardiography(TTE) in complex congenital heart diseases(CHD) in China.Methods:MEDLINE,Cochrane library and China National Knowledge Infrastructure(CNKI) database from January 1966 to October 2010,were searched for initial studies in China.All the studies,published in English or Chinese,used TTE,CT,or both as diagnostic tests for CHD and reported the rate of true-positive,true-negative,false-positive and false-negative diagnoses of CHD from TTE and CT findings with the surgical results as the 'gold-standard'(15 studies,XX patients) were collected.The statistic software package,'Meta-Disc 1.4',was used to conduct data analysis.A covariate analysis was used to evaluate the influence of patient or study-related factors on sensitivity.Results:Pooled sensitivity for diagnosis of CHD were 95% [95% confidence interval(CI):94%~96%] for CT studies and 87%(95% CI:85%~88%) for TTE studies.The difference between the pooled sensitivity of CT and that of TTE was statistically significant(P<0.001).TTE had higher sensitivity [0.96(95% CI:0.94~0.97)] for cardiac malformation but lower sensitivity [0.78(95% CI:0.76~0.81)] for extracardiac malformation than CT.Conclusion:CT can provide added diagnostic information compared with TTE in patients with CHD in China,especially for patients suspected of extracardiac malformation. 展开更多
关键词 ECHOCARDIOGRAPHY tomography X-ray computed Heart Defects Congenital META-ANALYSIS
在线阅读 下载PDF
Use of X-ray computed tomography to study structures and particle contacts of granite residual soil 被引量:19
3
作者 SUN Yin-lei TANG Lian-sheng 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第4期938-954,共17页
A small problem about soil particle regularization and contacts but essential to geotechnical engineering was studied.The soils sourced from Guangzhou and Xiamen were sieved into five different particle scale ranges(d... A small problem about soil particle regularization and contacts but essential to geotechnical engineering was studied.The soils sourced from Guangzhou and Xiamen were sieved into five different particle scale ranges(d<0.075 mm,0.075 mm≤d<0.1 mm,0.1 mm≤d<0.2 mm,0.2 mm≤d<0.5 mm and 0.5 mm≤d<1.0 mm)to study the structures and particle contacts of granite residual soil.The X-ray micro computed tomography method was used to reconstruct the microstructure of granite residual soil.The particle was identified and regularized using principal component analysis(PCA).The particle contacts and geometrical characteristics in 3D space were analyzed and summarized using statistical analyses.The results demonstrate that the main types of contact among the particles are face-face,face-angle,face-edge,edge-edge,edge-angle and angle-angle contacts for particle sizes less than 0.2 mm.When the particle sizes are greater than 0.2 mm,the contacts are effectively summarized as face-face,face-angle,face-edge,edge-edge,edge-angle,angle-angle,sphere-sphere,sphere-face,sphere-edge and sphere-angle contacts.The differences in porosity among the original sample,reconstructed sample and regularized sample are closely related to the water-swelling and water-disintegrable characteristics of granite residual soil. 展开更多
关键词 X-ray computed tomography granite residual soil RECONSTRUCTION REGULARIZATION particle contact
在线阅读 下载PDF
Characterization of microstructure evolution of cement paste by micro computed tomography 被引量:3
4
作者 何永佳 Jason Mote David A. Lange 《Journal of Central South University》 SCIE EI CAS 2013年第4期1115-1121,共7页
Micro computed tomography (Micro-CT) was applied to obtain three-dimensional images of the microstructure of cement paste (water-to-cement mass ratio of 0.5) at different ages. By using the Amira software, component p... Micro computed tomography (Micro-CT) was applied to obtain three-dimensional images of the microstructure of cement paste (water-to-cement mass ratio of 0.5) at different ages. By using the Amira software, component phases of the cement paste such as pores, hydration products, and unhydrated clinker particles were segmented from each other based on their 3D image grey levels; their relative contents were also calculated with the software, and the data are 61.2%, 0% and 38.8% at the beginning of hydration and 11.8%, 78.5% and 9.7% at 28 d age, respectively. The hydration degree of cement paste at different ages was compared with the experimental data acquired by loss on ignition (LOI) tests. The results show that the calculated and measured data reasonably agree with each other, which indicates that micro-CT is a useful and reliable approach to characterize the micro structure evolution of hydrating cement paste. 展开更多
关键词 Micro computed tomography (Micro-CT) 3D image MICROSTRUCTURE cement paste
在线阅读 下载PDF
Sparse Bayesian learning in ISAR tomography imaging
5
作者 苏伍各 王宏强 +2 位作者 邓彬 王瑞君 秦玉亮 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第5期1790-1800,共11页
Inverse synthetic aperture radar(ISAR) imaging can be regarded as a narrow-band version of the computer aided tomography(CT). The traditional CT imaging algorithms for ISAR, including the polar format algorithm(PFA) a... Inverse synthetic aperture radar(ISAR) imaging can be regarded as a narrow-band version of the computer aided tomography(CT). The traditional CT imaging algorithms for ISAR, including the polar format algorithm(PFA) and the convolution back projection algorithm(CBP), usually suffer from the problem of the high sidelobe and the low resolution. The ISAR tomography image reconstruction within a sparse Bayesian framework is concerned. Firstly, the sparse ISAR tomography imaging model is established in light of the CT imaging theory. Then, by using the compressed sensing(CS) principle, a high resolution ISAR image can be achieved with limited number of pulses. Since the performance of existing CS-based ISAR imaging algorithms is sensitive to the user parameter, this makes the existing algorithms inconvenient to be used in practice. It is well known that the Bayesian formalism of recover algorithm named sparse Bayesian learning(SBL) acts as an effective tool in regression and classification,which uses an efficient expectation maximization procedure to estimate the necessary parameters, and retains a preferable property of the l0-norm diversity measure. Motivated by that, a fully automated ISAR tomography imaging algorithm based on SBL is proposed.Experimental results based on simulated and electromagnetic(EM) data illustrate the effectiveness and the superiority of the proposed algorithm over the existing algorithms. 展开更多
关键词 inverse synthetic aperture radar (ISAR) tomography computer aided tomography (CT) imaging sparse recover compress sensing (CS) sparse Bayesian leaming (SBL)
在线阅读 下载PDF
Simulation study on ultrasonic tomography for grouted reinforced concrete by finite element
6
作者 朱自强 喻波 +2 位作者 李亚楠 肖嘉莹 周勇 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第7期2791-2799,共9页
A finite element reconstruction algorithm for ultrasound tomography based on the Helmholtz equation in frequency domain is presented to monitor the grouting defects in reinforced concrete structures.In this algorithm,... A finite element reconstruction algorithm for ultrasound tomography based on the Helmholtz equation in frequency domain is presented to monitor the grouting defects in reinforced concrete structures.In this algorithm,a hybrid regularizations-based iterative Newton method is implemented to provide stable inverse solutions.Furthermore,a dual mesh scheme and an adjoint method are adopted to reduce the computation cost and improve the efficiency of reconstruction.Simultaneous reconstruction of both acoustic velocity and attenuation coefficient for a reinforced concrete model is achieved with multiple frequency data.The algorithm is evaluated with numerical simulation under various practical scenarios including varied transmission/receiving modes,different noise levels,different source/detector numbers,and different contrast levels between the heterogeneity and background region.Results obtained suggest that the algorithm is insensitive to noise,and the reconstructions are quantitatively accurate in terms of the location,size and acoustic properties of the target over a range of contrast levels. 展开更多
关键词 ultrasound computed tomography nondestructive testing concrete exact field finite element method
在线阅读 下载PDF
Experimental and numerical study of fence effects on dust emission into atmosphere from open storage piles 被引量:2
7
作者 S.TORNO J.TORA-O +2 位作者 M MENéNDEZ M.GENT I.áLVAREZ 《Journal of Central South University》 SCIE EI CAS 2011年第2期411-419,共9页
The results obtained from the research on the behaviour of fences (solid and porous) in the protection against particulated material emission to the atmosphere from open storage piles,are presented. This research was ... The results obtained from the research on the behaviour of fences (solid and porous) in the protection against particulated material emission to the atmosphere from open storage piles,are presented. This research was carried out through computational fluid dynamics (CFD) simulation by software Ansys CFX-10.0 in 3D,with K-epsilon being considered in the turbulence model. The efficiency of the use of porous fences as a protection against the wind flow,which interacts with an open storage pile,is shown. The use of these fences (when porosity is ε=30%) allows the reduction of wind flow velocity which interacts with the pile in comparison with the case of no use of fences (when porosity is 100%). In addition,the use of porous fences makes the velocity vortex,which is formed between the solid fence (ε=0%) and the pile,disappear,reducing the particle emission to the atmosphere by 78%. 展开更多
关键词 open storage pile air pollution particle emission wind erosion porous fence computational fluid dynamics
在线阅读 下载PDF
儿童恶性肿瘤^(18)F-FDG PET/CT检查规范 被引量:1
8
作者 解朋 田蓉 +4 位作者 尹雅芙 孙晓蓉 朱小华 霍力 杨吉刚 《中国医学影像技术》 北大核心 2025年第1期2-5,共4页
^(18)F-FDG PET/CT是早期精准诊断儿童恶性肿瘤的理想辅助诊断工具。本指南旨在规范儿童恶性肿瘤^(18)F-FDG PET/CT检查流程,为核医学专业人员提供参考。
关键词 儿童 肿瘤 正电子发射断层显像术 体层摄影术 X线计算机
在线阅读 下载PDF
MR、PET及PET/MR脑成像鉴别阿尔茨海默病与额颞叶痴呆 被引量:3
9
作者 卢洁 《中国医学影像技术》 北大核心 2025年第2期186-190,共5页
阿尔茨海默病(AD)与额颞叶痴呆(FTD)均为常见痴呆类型。MRI、PET及PET/MRI可无创精准评估AD及FTD患者脑结构、功能及分子水平改变,对早期诊断及鉴别诊断具有重要价值。本文就MR、PET及PET/MR脑成像鉴别AD与FTD现状进行述评。
关键词 阿尔茨海默病 痴呆 正电子发射断层显像 磁共振成像
在线阅读 下载PDF
双能CT增强扫描联合肿瘤标记物对Ⅰ期卵巢癌的诊断价值 被引量:1
10
作者 李烨 刘爱连 +3 位作者 宋庆玲 郝丽 魏巍 刘义军 《中国临床医学影像杂志》 北大核心 2025年第6期421-425,436,共6页
目的:探讨双能CT增强扫描联合肿瘤标记物对Ⅰ期卵巢癌(OC)的诊断价值。方法:回顾性分析行双能CT增强三期扫描的168例OC患者(Ⅰ期:50例;非Ⅰ期:Ⅱ~Ⅳ期118例)的影像资料及肿瘤标记物(CA125、CA199和HE4)。两观察者分别测量和计算病灶实... 目的:探讨双能CT增强扫描联合肿瘤标记物对Ⅰ期卵巢癌(OC)的诊断价值。方法:回顾性分析行双能CT增强三期扫描的168例OC患者(Ⅰ期:50例;非Ⅰ期:Ⅱ~Ⅳ期118例)的影像资料及肿瘤标记物(CA125、CA199和HE4)。两观察者分别测量和计算病灶实性成分增强三期40~70 keV单能量(间隔10 keV)CT值、碘浓度(IC)及标准化碘浓度(NIC)。采用组内相关系数(ICC)检验两位观察者测量数据间一致性;采用独立样本t检验或Mann-Whitney U检验比较两组参数的差异。用Logistics回归分析建立Ⅰ期OC的联合模型。采用ROC曲线评估模型及各独立风险因素的诊断效能,用DeLong检验比较其AUC间差异,用混淆矩阵比较其敏感度、特异度间差异。结果:两观察者测量数据间一致性良好(ICC>0.75)。Ⅰ期OC患者的CA125、HE4及三期单能量CT值、IC、NIC低于非Ⅰ期OC患者(P<0.05)。联合模型(动脉期NIC+HE4)的AUC(0.875)高于独立风险因素HE4、动脉期NIC的AUC(0.792、0.824),P<0.05。联合模型敏感度高于HE4,特异度高于动脉期NIC,P<0.05。结论:双能CT增强扫描碘定量值联合HE4是术前识别Ⅰ期OC的有效方法。 展开更多
关键词 卵巢肿瘤 体层摄影术 X线计算机
在线阅读 下载PDF
帕金森病大脑皮层厚度与壳核多巴胺转运体的相关性 被引量:1
11
作者 王静 葛璟洁 +7 位作者 白侠 吴平 朱毓华 鲁佳荧 林华媚 张慧玮 张政伟 左传涛 《中国医学影像学杂志》 北大核心 2025年第3期280-285,共6页
目的探索不同时期帕金森病(PD)患者大脑皮层厚度特征及其与壳核多巴胺转运体(DAT)的相关性。资料与方法回顾性纳入2016年8月—2020年10月在复旦大学附属华山医院核医学/PET中心行^(11)C-CFTPET和T1MRI扫描的15名健康对照者和30例PD患者... 目的探索不同时期帕金森病(PD)患者大脑皮层厚度特征及其与壳核多巴胺转运体(DAT)的相关性。资料与方法回顾性纳入2016年8月—2020年10月在复旦大学附属华山医院核医学/PET中心行^(11)C-CFTPET和T1MRI扫描的15名健康对照者和30例PD患者。使用SPM12对PET进行图像预处理,获得壳核前部和后部的DAT平均放射性计数,以枕叶作为参考区计算DAT摄取值。使用Freesurfer v7.2软件中的标准处理方法对T1进行组织分割和皮层重建。采用一般线性模型,比较两组间左右脑的皮层厚度差异,并分析差异脑区的皮层厚度与壳核DAT摄取值的相关性。结果与健康对照组相比,PD患者的左侧顶下小叶和额中回下部、右侧额中回下部的皮层明显变薄(P均<0.05)。左侧顶下小叶、右侧额中回下部的皮层厚度与同侧壳核前/后部的DAT摄取值呈显著正相关(r=0.30~0.47,P均<0.05);右侧中央前回与同侧壳核后部的DAT摄取值呈显著正相关且相关性高于对侧(r=0.32,P=0.029)。结论本研究发现PD皮层变薄区域的厚度与壳核DAT水平存在显著正相关,提示了基底神经节皮层环路的重要性并为进一步研究PD神经机制提供依据。 展开更多
关键词 帕金森病 正电子发射断层显像 磁共振成像 多巴胺转运体蛋白 脑部皮层厚度
在线阅读 下载PDF
国产CT在儿童低剂量CT成像中的应用进展及挑战 被引量:1
12
作者 孙记航 钟玉敏 +2 位作者 牛延涛 葛英辉 彭芸 《中国医学影像技术》 北大核心 2025年第8期1284-1288,共5页
CT是儿科临床常用检查手段;制定并普及儿童低剂量CT扫描方案、构建标准化图像质量评价体系是儿童低剂量CT研究的重要方向。近年来,国产CT设备在硬件性能及图像重建算法方面取得突破,与人工智能技术相融合,为儿童低剂量CT成像提供了新的... CT是儿科临床常用检查手段;制定并普及儿童低剂量CT扫描方案、构建标准化图像质量评价体系是儿童低剂量CT研究的重要方向。近年来,国产CT设备在硬件性能及图像重建算法方面取得突破,与人工智能技术相融合,为儿童低剂量CT成像提供了新的路径。本文从扫描方案、建立图像质量评价体系及临床推广等方面对国产CT在儿童低剂量CT成像中的应用进展及挑战进行述评。 展开更多
关键词 儿童 辐射剂量 体层摄影术 X线计算机 图像质量
在线阅读 下载PDF
中国综合交通清洁低碳发展对策及减排效果评估与展望 被引量:2
13
作者 乔冰 林晶晶 《中国航海》 北大核心 2025年第2期151-158,共8页
综合交通清洁低碳发展对于防控与缓解危害人类可持续健康发展的大气环境问题具有重大意义,为此依据主管部门公开的铁路、公路、水路、民航、城市等5种运输方式的统计数据、可持续发展报告、污染防治规划,分别设定了铁水联运、中欧班列... 综合交通清洁低碳发展对于防控与缓解危害人类可持续健康发展的大气环境问题具有重大意义,为此依据主管部门公开的铁路、公路、水路、民航、城市等5种运输方式的统计数据、可持续发展报告、污染防治规划,分别设定了铁水联运、中欧班列、高铁客运、电子不停车收费(ETC)、车用燃料质量提升、港口效率提升、海运能效提升、船舶燃油质量提升、固液散货码头污染治理减排、民航节能减排能力提升、电动公交、轨道交通等12种关于清洁低碳发展的对策情景,提出了基于燃料法-运输能耗-排放因子-替代运输量的空气污染物及温室气体减排量计算模式和基于类比及统计分析等方法的12种对策情景减排量估算方法,根据估算的2013年以来的燃油及空气污染物和CO_(2)的减排量,对综合交通清洁低碳发展的成效进行了回顾,针对面临的问题与挑战对综合交通清洁低碳的发展做出了展望。 展开更多
关键词 交通清洁低碳发展 减排量 空气污染物 温室气体 减排对策 计算模型
在线阅读 下载PDF
^(18)F海藻糖-PET-CT技术或将为结核病临床研究带来革命性改变 被引量:1
14
作者 张培泽 高谦 邓国防 《中国防痨杂志》 北大核心 2025年第3期262-265,共4页
目前,结核病临床疗效评价依赖于传统的细菌学及影像学手段,难以满足临床需要。近期,Khan等报告了使用^(18)F海藻糖(2-[^(18)F]Fluoro-2-deoxy-trehalose,[^(18)F]FDT)标记体内活性结核分枝杆菌并通过PET-CT成像的技术。该技术使用[^(18)... 目前,结核病临床疗效评价依赖于传统的细菌学及影像学手段,难以满足临床需要。近期,Khan等报告了使用^(18)F海藻糖(2-[^(18)F]Fluoro-2-deoxy-trehalose,[^(18)F]FDT)标记体内活性结核分枝杆菌并通过PET-CT成像的技术。该技术使用[^(18)F]FDT实现了非人类的灵长类动物体内活性结核分枝杆菌的成像,并通过抗结核治疗前后[^(18)F]FDT摄取率的变化反映结核病的治疗疗效;而且,[^(18)F]FDT是主要经肾脏排泄的一种安全性良好的示踪剂。笔者认为,该技术的开发可能在结核病治疗终点判断、活动性结核病鉴别诊断、药物疗效判断及抗结核新药和疫苗研发等领域具有广阔的应用前景。本文中,笔者将该技术的成像原理、动物模型的研究结果作简要介绍,并探讨其在结核病临床研究中的应用场景,以供同行参考。 展开更多
关键词 结核 海藻糖 同位素标记 正电子发射断层显像术 综述文献(主题)
在线阅读 下载PDF
CTA联合超声血流参数评估颈动脉斑块稳定性 被引量:1
15
作者 张奇 郭翀 +3 位作者 范光亮 赵斌 钟晓飞 李克 《放射学实践》 北大核心 2025年第5期567-572,共6页
目的:探讨CTA联合超声血流参数对颈动脉斑块稳定性的评估价值。方法:纳入2021年1月至2023年12月于滨州医学院附属医院就诊并接受颈内动脉剥脱术的102例颈动脉粥样硬化(CAS)斑块患者作为研究对象,根据术后病理检查结果将斑块分为稳定性... 目的:探讨CTA联合超声血流参数对颈动脉斑块稳定性的评估价值。方法:纳入2021年1月至2023年12月于滨州医学院附属医院就诊并接受颈内动脉剥脱术的102例颈动脉粥样硬化(CAS)斑块患者作为研究对象,根据术后病理检查结果将斑块分为稳定性斑块组(62例)和不稳定性斑块组(40例)。所有患者均于入院后行头颈部CTA检查,记录点状钙化、低衰减斑块、餐巾环征、正性重构、钙化斑块体积、脂质斑块体积、纤维斑块体积及最大斑块长度;并进行超声检查,对峰值收缩期流速(PSV)、舒张末期流速(EDV)、收缩期与舒张期流速比率(S/D)、阻力指数(RI)、搏动指数(PI)、管腔狭窄程度、回声强弱进行记录。结果:与不稳定斑块组相比,稳定斑块组的低衰减斑块出现比例显著降低,钙化斑块体积、PSV、EDV显著升高,脂质斑块体积、RI显著降低,管腔狭窄程度较轻、斑块回声较强,差异有统计学意义(P<0.05);而S/D和PI在两组间差异无统计学意义(P>0.05)。多因素Logistic回归分析结果显示,低衰减斑块、较大的脂质斑块体积、较低的PSV和EDV、较严重的管腔狭窄程度、较低的斑块回声,是不稳定斑块的独立影响因素(P<0.05)。ROC曲线分析结果显示,CTA联合超声血流参数评估不稳定斑块的AUC为0.910(95%CI:0.851~0.970),敏感度和特异度分别为90.0%和83.9%。结论:CTA联合超声血流参数对于不稳定CAS斑块的无创性诊断具有较高的效能,可为临床诊疗提供重要参考依据。 展开更多
关键词 CT血管成像 超声检查 体层摄影术 X线计算机 颈动脉粥样硬化斑块 稳定性
在线阅读 下载PDF
影像学评估肝脏体积的研究进展 被引量:1
16
作者 张益铭 张小燕 +2 位作者 乔苗苗 王苗苗 郭顺林 《磁共振成像》 北大核心 2025年第6期195-200,227,共7页
肝脏体积(liver volume,LV)的测量在疾病诊断、手术规划和预后评估中具有重要临床价值。随着医学影像技术的不断进步,肝脏体积测量方法经历了从传统手动测量到现代自动化分割的显著演变。然而,现有技术仍面临诸多挑战,如传统手动测量耗... 肝脏体积(liver volume,LV)的测量在疾病诊断、手术规划和预后评估中具有重要临床价值。随着医学影像技术的不断进步,肝脏体积测量方法经历了从传统手动测量到现代自动化分割的显著演变。然而,现有技术仍面临诸多挑战,如传统手动测量耗时并存在主观差异,半自动或早期自动化方法测量误差高等。研究发现,基于深度学习(deep learning,DL)等人工智能(artificial intelligence,AI)技术能够提高肝脏体积测量的精度和效率,尤其在异质性病变和边界模糊区域中表现突出。近年来,尚未有系统性的文章对其进行综述。本文深入回顾了肝脏体积测量技术的演进历程,对比分析了不同技术的优劣,重点探讨了AI在该领域的突破性进展,但其仍存在对某些复杂病例的泛化能力不足、依赖高质量标注数据等局限性。因此,未来研究应聚焦于影像技术优化、高效自动化算法开发、多模态融合及鲁棒性AI模型构建等方向,推动肝脏体积测量的精准化和临床应用,以期为临床实践和技术创新提供系统性参考。 展开更多
关键词 肝脏疾病 肝切除术 肝脏体积测量 磁共振成像 计算机断层扫描 人工智能
在线阅读 下载PDF
深度学习全模型迭代算法(AIIR)临床应用价值 被引量:3
17
作者 洪楠 《中国医学影像技术》 北大核心 2025年第4期513-514,共2页
深度学习全模型迭代算法(AIIR)创新性地将全模型迭代与深度学习技术相结合,以弥补传统CT重建方法在噪声伪影抑制及纹理表现等方面的局限而提高图像质量;其用于低剂量成像及复杂解剖结构成像表现不俗,可为患者安全及精准诊断提供有力保... 深度学习全模型迭代算法(AIIR)创新性地将全模型迭代与深度学习技术相结合,以弥补传统CT重建方法在噪声伪影抑制及纹理表现等方面的局限而提高图像质量;其用于低剂量成像及复杂解剖结构成像表现不俗,可为患者安全及精准诊断提供有力保障。本文针对AIIR临床应用价值进行述评。 展开更多
关键词 体层摄影术 X线计算机 图像处理 计算机辅助 深度学习 辐射剂量 图像质量
在线阅读 下载PDF
1例表现为肺门区单发PSMA浓聚灶的原发肺腺癌误诊为前列腺癌肺门淋巴结转移
18
作者 祝安惠 张安南 +3 位作者 张帆 彭冉 贺慧颖 张卫方 《中国医学影像技术》 北大核心 2025年第10期1777-1778,共2页
患者男,76岁,无明显诱因腹痛2个月;既往体健;查体未见明显异常。实验室检查:总前列腺特异性抗原>100 ng/ml。^(18)F-PSMA PET/CT:前列腺增大,^(18)F-PSMA摄取不均匀增高,最大标准摄取值(maximun standard uptake value,SUV_(max))3.2... 患者男,76岁,无明显诱因腹痛2个月;既往体健;查体未见明显异常。实验室检查:总前列腺特异性抗原>100 ng/ml。^(18)F-PSMA PET/CT:前列腺增大,^(18)F-PSMA摄取不均匀增高,最大标准摄取值(maximun standard uptake value,SUV_(max))3.2;左侧腋窝、腹盆腔及腰椎多发浓聚灶,最大SUV_(max)92.8;左肺门单发浓聚灶,SUV_(max)3.5(图1A、1B)。 展开更多
关键词 肺腺癌 前列腺肿瘤 正电子发射断层显像和计算机体层摄影术
在线阅读 下载PDF
^(18)F-FDG PET/CT显像半定量参数SUVmax、TBR与大动脉炎疾病活动性的关系
19
作者 张晶晶 温鑫 +2 位作者 阮翘 韩星敏 王瑞华 《中国医学影像学杂志》 北大核心 2025年第5期562-566,共5页
目的探讨^(18)F-FDG PET/CT显像半定量参数最大标准化摄取值(SUVmax)和靶/本比(TBR)与大动脉炎疾病活动性的关系。资料与方法回顾性收集2016年2月—2022年12月郑州大学第一附属医院大动脉炎患者110例,根据Kerr评分将患者分为临床活动组9... 目的探讨^(18)F-FDG PET/CT显像半定量参数最大标准化摄取值(SUVmax)和靶/本比(TBR)与大动脉炎疾病活动性的关系。资料与方法回顾性收集2016年2月—2022年12月郑州大学第一附属医院大动脉炎患者110例,根据Kerr评分将患者分为临床活动组92例和非活动组18例。所有患者均行^(18)F-FDG PET/CT显像,采用感兴趣区技术测量动脉壁SUVmax,将SUVmax分别与下腔静脉中心平均SUV及肝右叶最大SUV相比得到TBR_(血池)、TBR_(肝)。采用受试者工作特征曲线比较SUVmax、TBR_(血池)、TBR_(肝)对大动脉炎活动性的诊断效能,评价PET/CT各参数与Kerr评分、红细胞沉降率、C反应蛋白的关系。结果临床活动组的SUVmax、TBR_(血池)和TBR_(肝)均明显高于非活动组[3.70(3.03,5.18)比1.45(1.38,1.53)、2.50(1.93,3.88)比0.91(0.79,1.16)、1.37(1.00,1.96)比0.44(0.39,0.63);Z=5.510~5.900,P均<0.001];SUVmax判断大动脉炎疾病活动性的最佳界值为2.65(敏感度为83.7%,特异度为100%,曲线下面积为0.91);TBR_(血池)判断大动脉炎疾病活动性的最佳界值为1.63(敏感度为83.7%,特异度为94.4%,曲线下面积为0.93);TBR_(肝)判断大动脉炎疾病活动性的最佳界值为0.81(敏感度为87.0%,特异度为100%,曲线下面积为0.94)。SUVmax、TBR_(血池)、TBR_(肝)与Kerr评分均呈正相关(r=0.88、0.89、0.90,P均<0.001),以TBR_(肝)与Kerr评分的相关系数最高。结论SUVmax、TBR_(血池)、TBR_(肝)有助于评估大动脉炎患者疾病活动性,以TBR_(肝)最佳。 展开更多
关键词 大动脉炎 正电子发射计算机断层摄影术 疾病活动性 氟脱氧葡萄糖F18 诊断
在线阅读 下载PDF
SPECT/CT图像质量及检出骨转移癌能力:比较国产Insight NM/CT Pro SPECT/CT仪与Siemens Symbia T16 SPECT/CT仪
20
作者 赵振峰 王瑞 +4 位作者 周伟娜 刘磊 郝喜燕 牛瑞龙 王雪梅 《中国医学影像技术》 北大核心 2025年第6期967-970,共4页
目的比较国产Insight NM/CT Pro SPECT/CT仪(永新SPECT/CT仪)与Siemens Symbia T16 SPECT/CT仪(Symbia T16 SPECT/CT仪)图像质量及检出骨转移癌能力。方法前瞻性对40例确诊或疑诊骨转移癌患者分别采用国产永新SPECT/CT仪及Symbia T16 SP... 目的比较国产Insight NM/CT Pro SPECT/CT仪(永新SPECT/CT仪)与Siemens Symbia T16 SPECT/CT仪(Symbia T16 SPECT/CT仪)图像质量及检出骨转移癌能力。方法前瞻性对40例确诊或疑诊骨转移癌患者分别采用国产永新SPECT/CT仪及Symbia T16 SPECT/CT仪以相同方法及参数进行全身骨显像及局部融合显像,比较2种设备所获图像质量及其检出病灶能力。结果40例中,以Symbia T16 SPECT/CT仪所获全身骨显像图像质量为5分者35例、4分5例,检出118处阳性病灶,累及胸部36处、脊柱28处、骨盆30处、四肢20处、颅骨4处;局部断层融合显像图像质量均为5分,检出59处阳性病灶,CT表现为骨质破坏14处、骨密度增高11处、骨密度不均匀34处。利用永新SPECT/CT仪所获全身骨显像图像质量为5分者35例、4分4例、3分1例,检出阳性病灶及其累及骨骼区域均与Symbia T16 SPECT/CT仪一致,所获局部融合显像图像质量、检出阳性病灶累及区域,以及CT表现亦均与Symbia T16 SPECT/CT仪相符。结论国产永新SPECT/CT仪图像质量及检出骨转移癌能力均与Siemens Symbia T16 SPECT/CT仪相当。 展开更多
关键词 骨肿瘤 图像质量 单光子发射断层显像和计算机体层摄影 前瞻性研究
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部