Malignant tumours always threaten human health.For tumour diagnosis,positron emission tomography(PET)is the most sensitive and advanced imaging technique by radiotracers,such as radioactive^(18)F,^(11)C,^(64)Cu,^(68)G...Malignant tumours always threaten human health.For tumour diagnosis,positron emission tomography(PET)is the most sensitive and advanced imaging technique by radiotracers,such as radioactive^(18)F,^(11)C,^(64)Cu,^(68)Ga,and^(89)Zr.Among the radiotracers,the radioactive^(18)F-labelled chemical agent as PET probes plays a predominant role in monitoring,detecting,treating,and predicting tumours due to its perfect half-life.In this paper,the^(18)F-labelled chemical materials as PET probes are systematically summarized.First,we introduce various radionuclides of PET and elaborate on the mechanism of PET imaging.It highlights the^(18)F-labelled chemical agents used as PET probes,including[^(18)F]-2-deoxy-2-[^(18)F]fluoro-D-glucose([^(18)F]-FDG),^(18)F-labelled amino acids,^(18)F-labelled nucleic acids,^(18)F-labelled receptors,^(18)F-labelled reporter genes,and^(18)F-labelled hypoxia agents.In addition,some PET probes with metal as a supplementary element are introduced briefly.Meanwhile,the^(18)F-labelled nanoparticles for the PET probe and the multi-modality imaging probe are summarized in detail.The approach and strategies for the fabrication of^(18)F-labelled PET probes are also described briefly.The future development of the PET probe is also prospected.The development and application of^(18)F-labelled PET probes will expand our knowledge and shed light on the diagnosis and theranostics of tumours.展开更多
Objective:To perform a meta-analysis to evaluate the diagnostic performance of computed tomography(CT) and transthoracic echocardiography(TTE) in complex congenital heart diseases(CHD) in China.Methods:MEDLINE,Cochran...Objective:To perform a meta-analysis to evaluate the diagnostic performance of computed tomography(CT) and transthoracic echocardiography(TTE) in complex congenital heart diseases(CHD) in China.Methods:MEDLINE,Cochrane library and China National Knowledge Infrastructure(CNKI) database from January 1966 to October 2010,were searched for initial studies in China.All the studies,published in English or Chinese,used TTE,CT,or both as diagnostic tests for CHD and reported the rate of true-positive,true-negative,false-positive and false-negative diagnoses of CHD from TTE and CT findings with the surgical results as the 'gold-standard'(15 studies,XX patients) were collected.The statistic software package,'Meta-Disc 1.4',was used to conduct data analysis.A covariate analysis was used to evaluate the influence of patient or study-related factors on sensitivity.Results:Pooled sensitivity for diagnosis of CHD were 95% [95% confidence interval(CI):94%~96%] for CT studies and 87%(95% CI:85%~88%) for TTE studies.The difference between the pooled sensitivity of CT and that of TTE was statistically significant(P<0.001).TTE had higher sensitivity [0.96(95% CI:0.94~0.97)] for cardiac malformation but lower sensitivity [0.78(95% CI:0.76~0.81)] for extracardiac malformation than CT.Conclusion:CT can provide added diagnostic information compared with TTE in patients with CHD in China,especially for patients suspected of extracardiac malformation.展开更多
A small problem about soil particle regularization and contacts but essential to geotechnical engineering was studied.The soils sourced from Guangzhou and Xiamen were sieved into five different particle scale ranges(d...A small problem about soil particle regularization and contacts but essential to geotechnical engineering was studied.The soils sourced from Guangzhou and Xiamen were sieved into five different particle scale ranges(d<0.075 mm,0.075 mm≤d<0.1 mm,0.1 mm≤d<0.2 mm,0.2 mm≤d<0.5 mm and 0.5 mm≤d<1.0 mm)to study the structures and particle contacts of granite residual soil.The X-ray micro computed tomography method was used to reconstruct the microstructure of granite residual soil.The particle was identified and regularized using principal component analysis(PCA).The particle contacts and geometrical characteristics in 3D space were analyzed and summarized using statistical analyses.The results demonstrate that the main types of contact among the particles are face-face,face-angle,face-edge,edge-edge,edge-angle and angle-angle contacts for particle sizes less than 0.2 mm.When the particle sizes are greater than 0.2 mm,the contacts are effectively summarized as face-face,face-angle,face-edge,edge-edge,edge-angle,angle-angle,sphere-sphere,sphere-face,sphere-edge and sphere-angle contacts.The differences in porosity among the original sample,reconstructed sample and regularized sample are closely related to the water-swelling and water-disintegrable characteristics of granite residual soil.展开更多
Micro computed tomography (Micro-CT) was applied to obtain three-dimensional images of the microstructure of cement paste (water-to-cement mass ratio of 0.5) at different ages. By using the Amira software, component p...Micro computed tomography (Micro-CT) was applied to obtain three-dimensional images of the microstructure of cement paste (water-to-cement mass ratio of 0.5) at different ages. By using the Amira software, component phases of the cement paste such as pores, hydration products, and unhydrated clinker particles were segmented from each other based on their 3D image grey levels; their relative contents were also calculated with the software, and the data are 61.2%, 0% and 38.8% at the beginning of hydration and 11.8%, 78.5% and 9.7% at 28 d age, respectively. The hydration degree of cement paste at different ages was compared with the experimental data acquired by loss on ignition (LOI) tests. The results show that the calculated and measured data reasonably agree with each other, which indicates that micro-CT is a useful and reliable approach to characterize the micro structure evolution of hydrating cement paste.展开更多
Inverse synthetic aperture radar(ISAR) imaging can be regarded as a narrow-band version of the computer aided tomography(CT). The traditional CT imaging algorithms for ISAR, including the polar format algorithm(PFA) a...Inverse synthetic aperture radar(ISAR) imaging can be regarded as a narrow-band version of the computer aided tomography(CT). The traditional CT imaging algorithms for ISAR, including the polar format algorithm(PFA) and the convolution back projection algorithm(CBP), usually suffer from the problem of the high sidelobe and the low resolution. The ISAR tomography image reconstruction within a sparse Bayesian framework is concerned. Firstly, the sparse ISAR tomography imaging model is established in light of the CT imaging theory. Then, by using the compressed sensing(CS) principle, a high resolution ISAR image can be achieved with limited number of pulses. Since the performance of existing CS-based ISAR imaging algorithms is sensitive to the user parameter, this makes the existing algorithms inconvenient to be used in practice. It is well known that the Bayesian formalism of recover algorithm named sparse Bayesian learning(SBL) acts as an effective tool in regression and classification,which uses an efficient expectation maximization procedure to estimate the necessary parameters, and retains a preferable property of the l0-norm diversity measure. Motivated by that, a fully automated ISAR tomography imaging algorithm based on SBL is proposed.Experimental results based on simulated and electromagnetic(EM) data illustrate the effectiveness and the superiority of the proposed algorithm over the existing algorithms.展开更多
A finite element reconstruction algorithm for ultrasound tomography based on the Helmholtz equation in frequency domain is presented to monitor the grouting defects in reinforced concrete structures.In this algorithm,...A finite element reconstruction algorithm for ultrasound tomography based on the Helmholtz equation in frequency domain is presented to monitor the grouting defects in reinforced concrete structures.In this algorithm,a hybrid regularizations-based iterative Newton method is implemented to provide stable inverse solutions.Furthermore,a dual mesh scheme and an adjoint method are adopted to reduce the computation cost and improve the efficiency of reconstruction.Simultaneous reconstruction of both acoustic velocity and attenuation coefficient for a reinforced concrete model is achieved with multiple frequency data.The algorithm is evaluated with numerical simulation under various practical scenarios including varied transmission/receiving modes,different noise levels,different source/detector numbers,and different contrast levels between the heterogeneity and background region.Results obtained suggest that the algorithm is insensitive to noise,and the reconstructions are quantitatively accurate in terms of the location,size and acoustic properties of the target over a range of contrast levels.展开更多
The results obtained from the research on the behaviour of fences (solid and porous) in the protection against particulated material emission to the atmosphere from open storage piles,are presented. This research was ...The results obtained from the research on the behaviour of fences (solid and porous) in the protection against particulated material emission to the atmosphere from open storage piles,are presented. This research was carried out through computational fluid dynamics (CFD) simulation by software Ansys CFX-10.0 in 3D,with K-epsilon being considered in the turbulence model. The efficiency of the use of porous fences as a protection against the wind flow,which interacts with an open storage pile,is shown. The use of these fences (when porosity is ε=30%) allows the reduction of wind flow velocity which interacts with the pile in comparison with the case of no use of fences (when porosity is 100%). In addition,the use of porous fences makes the velocity vortex,which is formed between the solid fence (ε=0%) and the pile,disappear,reducing the particle emission to the atmosphere by 78%.展开更多
文摘Malignant tumours always threaten human health.For tumour diagnosis,positron emission tomography(PET)is the most sensitive and advanced imaging technique by radiotracers,such as radioactive^(18)F,^(11)C,^(64)Cu,^(68)Ga,and^(89)Zr.Among the radiotracers,the radioactive^(18)F-labelled chemical agent as PET probes plays a predominant role in monitoring,detecting,treating,and predicting tumours due to its perfect half-life.In this paper,the^(18)F-labelled chemical materials as PET probes are systematically summarized.First,we introduce various radionuclides of PET and elaborate on the mechanism of PET imaging.It highlights the^(18)F-labelled chemical agents used as PET probes,including[^(18)F]-2-deoxy-2-[^(18)F]fluoro-D-glucose([^(18)F]-FDG),^(18)F-labelled amino acids,^(18)F-labelled nucleic acids,^(18)F-labelled receptors,^(18)F-labelled reporter genes,and^(18)F-labelled hypoxia agents.In addition,some PET probes with metal as a supplementary element are introduced briefly.Meanwhile,the^(18)F-labelled nanoparticles for the PET probe and the multi-modality imaging probe are summarized in detail.The approach and strategies for the fabrication of^(18)F-labelled PET probes are also described briefly.The future development of the PET probe is also prospected.The development and application of^(18)F-labelled PET probes will expand our knowledge and shed light on the diagnosis and theranostics of tumours.
文摘Objective:To perform a meta-analysis to evaluate the diagnostic performance of computed tomography(CT) and transthoracic echocardiography(TTE) in complex congenital heart diseases(CHD) in China.Methods:MEDLINE,Cochrane library and China National Knowledge Infrastructure(CNKI) database from January 1966 to October 2010,were searched for initial studies in China.All the studies,published in English or Chinese,used TTE,CT,or both as diagnostic tests for CHD and reported the rate of true-positive,true-negative,false-positive and false-negative diagnoses of CHD from TTE and CT findings with the surgical results as the 'gold-standard'(15 studies,XX patients) were collected.The statistic software package,'Meta-Disc 1.4',was used to conduct data analysis.A covariate analysis was used to evaluate the influence of patient or study-related factors on sensitivity.Results:Pooled sensitivity for diagnosis of CHD were 95% [95% confidence interval(CI):94%~96%] for CT studies and 87%(95% CI:85%~88%) for TTE studies.The difference between the pooled sensitivity of CT and that of TTE was statistically significant(P<0.001).TTE had higher sensitivity [0.96(95% CI:0.94~0.97)] for cardiac malformation but lower sensitivity [0.78(95% CI:0.76~0.81)] for extracardiac malformation than CT.Conclusion:CT can provide added diagnostic information compared with TTE in patients with CHD in China,especially for patients suspected of extracardiac malformation.
基金Projects(41572277,41877229)supported by the National Natural Science Foundation of ChinaProject(2015A030313118)supported by the Natural Science Foundation of Guangdong Province,ChinaProject(201607010023)supported by the Science and Technology Program of Guangzhou,China
文摘A small problem about soil particle regularization and contacts but essential to geotechnical engineering was studied.The soils sourced from Guangzhou and Xiamen were sieved into five different particle scale ranges(d<0.075 mm,0.075 mm≤d<0.1 mm,0.1 mm≤d<0.2 mm,0.2 mm≤d<0.5 mm and 0.5 mm≤d<1.0 mm)to study the structures and particle contacts of granite residual soil.The X-ray micro computed tomography method was used to reconstruct the microstructure of granite residual soil.The particle was identified and regularized using principal component analysis(PCA).The particle contacts and geometrical characteristics in 3D space were analyzed and summarized using statistical analyses.The results demonstrate that the main types of contact among the particles are face-face,face-angle,face-edge,edge-edge,edge-angle and angle-angle contacts for particle sizes less than 0.2 mm.When the particle sizes are greater than 0.2 mm,the contacts are effectively summarized as face-face,face-angle,face-edge,edge-edge,edge-angle,angle-angle,sphere-sphere,sphere-face,sphere-edge and sphere-angle contacts.The differences in porosity among the original sample,reconstructed sample and regularized sample are closely related to the water-swelling and water-disintegrable characteristics of granite residual soil.
基金Project(2009CB623201) supported by the National Basic Research Program of ChinaProjects(50902106, 51272193) supported by the National Natural Science Foundation of ChinaProject(NCET-10-0660) supported by New Century Excellent Talents in Universities of China
文摘Micro computed tomography (Micro-CT) was applied to obtain three-dimensional images of the microstructure of cement paste (water-to-cement mass ratio of 0.5) at different ages. By using the Amira software, component phases of the cement paste such as pores, hydration products, and unhydrated clinker particles were segmented from each other based on their 3D image grey levels; their relative contents were also calculated with the software, and the data are 61.2%, 0% and 38.8% at the beginning of hydration and 11.8%, 78.5% and 9.7% at 28 d age, respectively. The hydration degree of cement paste at different ages was compared with the experimental data acquired by loss on ignition (LOI) tests. The results show that the calculated and measured data reasonably agree with each other, which indicates that micro-CT is a useful and reliable approach to characterize the micro structure evolution of hydrating cement paste.
基金Project(61171133)supported by the National Natural Science Foundation of ChinaProject(11JJ1010)supported by the Natural Science Fund for Distinguished Young Scholars of Hunan Province,ChinaProject(61101182)supported by the National Natural Science Foundation for Young Scientists of China
文摘Inverse synthetic aperture radar(ISAR) imaging can be regarded as a narrow-band version of the computer aided tomography(CT). The traditional CT imaging algorithms for ISAR, including the polar format algorithm(PFA) and the convolution back projection algorithm(CBP), usually suffer from the problem of the high sidelobe and the low resolution. The ISAR tomography image reconstruction within a sparse Bayesian framework is concerned. Firstly, the sparse ISAR tomography imaging model is established in light of the CT imaging theory. Then, by using the compressed sensing(CS) principle, a high resolution ISAR image can be achieved with limited number of pulses. Since the performance of existing CS-based ISAR imaging algorithms is sensitive to the user parameter, this makes the existing algorithms inconvenient to be used in practice. It is well known that the Bayesian formalism of recover algorithm named sparse Bayesian learning(SBL) acts as an effective tool in regression and classification,which uses an efficient expectation maximization procedure to estimate the necessary parameters, and retains a preferable property of the l0-norm diversity measure. Motivated by that, a fully automated ISAR tomography imaging algorithm based on SBL is proposed.Experimental results based on simulated and electromagnetic(EM) data illustrate the effectiveness and the superiority of the proposed algorithm over the existing algorithms.
基金Project(31200748)supported by the National Natural Science Foundation of China
文摘A finite element reconstruction algorithm for ultrasound tomography based on the Helmholtz equation in frequency domain is presented to monitor the grouting defects in reinforced concrete structures.In this algorithm,a hybrid regularizations-based iterative Newton method is implemented to provide stable inverse solutions.Furthermore,a dual mesh scheme and an adjoint method are adopted to reduce the computation cost and improve the efficiency of reconstruction.Simultaneous reconstruction of both acoustic velocity and attenuation coefficient for a reinforced concrete model is achieved with multiple frequency data.The algorithm is evaluated with numerical simulation under various practical scenarios including varied transmission/receiving modes,different noise levels,different source/detector numbers,and different contrast levels between the heterogeneity and background region.Results obtained suggest that the algorithm is insensitive to noise,and the reconstructions are quantitatively accurate in terms of the location,size and acoustic properties of the target over a range of contrast levels.
基金the Spanish Ministry of Science and Education that granted these researches through the project CTM2005-00187/TECNO "Prediction Models and Prevention Systems in the Particle Atmospheric Pollution in an Industrial Environment" carried out at Oviedo University
文摘The results obtained from the research on the behaviour of fences (solid and porous) in the protection against particulated material emission to the atmosphere from open storage piles,are presented. This research was carried out through computational fluid dynamics (CFD) simulation by software Ansys CFX-10.0 in 3D,with K-epsilon being considered in the turbulence model. The efficiency of the use of porous fences as a protection against the wind flow,which interacts with an open storage pile,is shown. The use of these fences (when porosity is ε=30%) allows the reduction of wind flow velocity which interacts with the pile in comparison with the case of no use of fences (when porosity is 100%). In addition,the use of porous fences makes the velocity vortex,which is formed between the solid fence (ε=0%) and the pile,disappear,reducing the particle emission to the atmosphere by 78%.