Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised...Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised due to cost and performance issues, many of which are linked to the microstructure of the porous carbon electrodes used. Here, for the first time, we offer a detailed study of the in situ effects of compression on a commercially available carbon felt electrode. Visualisation of electrode structure us- ing X-ray computed tomography shows the non-linear way that these materials compress and various metrics are used to elucidate the changes in porosity, pore size distribution and tortuosity factor under compressions from 0%-90%.展开更多
The relationship between noise variance and spatial resolution in grating-based x-ray phase computed tomography(PCT) imaging is investigated with reverse projection extraction method, and the noise variances of the ...The relationship between noise variance and spatial resolution in grating-based x-ray phase computed tomography(PCT) imaging is investigated with reverse projection extraction method, and the noise variances of the reconstructed absorption coefficient and refractive index decrement are compared. For the differential phase contrast method, the noise variance in the differential projection images follows the same inverse-square law with spatial resolution as in conventional absorption-based x-ray imaging projections. However, both theoretical analysis and simulations demonstrate that in PCT the noise variance of the reconstructed refractive index decrement scales with spatial resolution follows an inverse linear relationship at fixed slice thickness, while the noise variance of the reconstructed absorption coefficient conforms with the inverse cubic law. The results indicate that, for the same noise variance level, PCT imaging may enable higher spatial resolution than conventional absorption computed tomography(ACT), while ACT benefits more from degraded spatial resolution. This could be a useful guidance in imaging the inner structure of the sample in higher spatial resolution.展开更多
The geometric and spatial characteristics of pore structures determine the permeability and water retention of soils, which have important effects on soil functional diversity and ecological restoration. Until recentl...The geometric and spatial characteristics of pore structures determine the permeability and water retention of soils, which have important effects on soil functional diversity and ecological restoration. Until recently, there have not been tools and methods to visually and quantitatively describe the characteristics of soil pores. To solve this problem, this research reconstructs the geometry and spatial distribution of soil pores by the marching cubes method, texture mapping method and the ray casting method widely used in literature. The objectives were to explore an optimal method for three-dimensional visualization of soil pore structure by comparing the robustness of the three methods on soil CT images with single pore structure and porosity ranging from low (2–5%) to high (12–18%), and to evaluate the reconstruction performance of the three methods with different geometric features. The results demonstrate that there are aliases (jagged edges) and deficiency at the boundaries of the model reconstructed by the marching cubes method and pore volumes are smaller than the ground truth, whereas the results of the texture mapping method lack the details of pore structures. For all the soil images, the ray casting method is preferable since it better preserves the pore characteristics of the ground truth. Furthermore, the ray casting method produced the best soil pore model with higher rendering speed and lower memory consumption. Therefore, the ray casting method provides a more advanced method for visualization of pore structures and provides an optional technique for the study of the transport of moisture and the exchange of air in soil.展开更多
A new method in diffraction-enhanced imaging computed tomography (DEI-CT) that follows the idea developed by Chapman et al. [Chapman D, Thomlinson W, Johnston R E, Washburn D, Pisano E, Gmur N, Zhong Z, Menk R, Arfe...A new method in diffraction-enhanced imaging computed tomography (DEI-CT) that follows the idea developed by Chapman et al. [Chapman D, Thomlinson W, Johnston R E, Washburn D, Pisano E, Gmur N, Zhong Z, Menk R, Arfelli F and Sayers D 1997 Phys. Med. BioL 42 2015] in 1997 is proposed in this paper. Merged with a "reverse projections" algorithm, only two sets of projection datasets at two defined orientations of the analyzer crystal are needed to reconstruct the linear absorption coefficient, the decrement of the real part of the refractive index and the linear scattering coefficient of the sample. Not only does this method reduce the delivered dose to the sample without degrading the image quality, but, compared with the existing DEI-CT approaches, it simplifies data-acquisition procedures. Experimental results confirm the reliability of this new method for DEI-CT applications.展开更多
A penetrating view of the three-dimensional nanostructure of female spermatheca and male flagellum in the species Aleochara verna is obtained with 100-nm resolution using a hard X-ray microscope, which provides a fast...A penetrating view of the three-dimensional nanostructure of female spermatheca and male flagellum in the species Aleochara verna is obtained with 100-nm resolution using a hard X-ray microscope, which provides a fast noninvasive imaging technology for insect morphology. Through introducing Zernike phase contrast and heavy metal staining, images taken at 8 keV displayed sufficient contrast for observing nanoscale fine structures, such as the spermatheca cochleate duct and the subapex of the flagellum, which have some implications for the study of the sperm transfer process and genital evolution in insects. This work shows that both the spatial resolution and the contrast characteristic of hard X-ray microscopy are quite promising for insect morphology studies and, particularly, provide an attractive alternative to the destructive techniques used for investigating internal soft tissues.展开更多
X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping informa...X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping information extraction method reduces system stability and prolongs data acquisition time by several times compared with conventional x-ray absorption- based imaging. The mechanical stepping can be avoided by using a staggered grating, but at the cost of low vertical spatial resolution. In this paper, employing a modified staggered grating and the angular signal radiography, we proposed a single-shot grating-based x-ray differential phase contrast imaging with decent vertical spatial resolution. The theoretical framework was deduced and proved by numerical experiments. Absorption, phase, and scattering computed tomography can be performed without phase stepping. Therefore, we believe this fast and highly stable imaging method with decent resolution would be widely applied in x-ray grating-based phase contrast imaging.展开更多
BACKGROUND:The appropriate sequence of different imagings and indications of thoracic computed tomography(TCT)in evaluating chest trauma have not yet been clarified at present.The current study was undertaken to deter...BACKGROUND:The appropriate sequence of different imagings and indications of thoracic computed tomography(TCT)in evaluating chest trauma have not yet been clarified at present.The current study was undertaken to determine the value of chest X-ray(CXR)in detecting chest injuries in patients with blunt trauma.METHODS:A total of 447 patients with blunt thoracic trauma who had been admitted to the emergency department(ED)in the period of 2009–2013 were retrospectively reviewed.The patients met inclusion criteria(age>8 years,blunt injury to the chest,hemodynamically stable,and neurologically intact)and underwent both TCT and upright CXR in the ED.Radiological imagings were re-interpreted after they were collected from the hospital database by two skilled radiologists.RESULTS:Of the 447 patients,309(69.1%)were male.The mean age of the 447 patients was 39.5±19.2(range 9 and 87 years).158(35.3%)patients were injured in motor vehicle accidents(MVA).CXR showed the highest sensitivity in detecting clavicle fractures[95%CI 78.3(63.6–89)]but the lowest in pneuomediastinum[95%CI 11.8(1.5–36.4)].The specificity of CXR was close to 100%in detecting a wide array of entities.CONCLUSION:CXR remains to be the first choice in hemodynamically unstable patients with blunt chest trauma.Moreover,stable patients with normal CXR are candidates who should undergo TCT if significant injury has not been ruled out.展开更多
A precise knowledge of geometry is always pivotal to a 3-D X-ray imaging system,such as computed tomography(CT),digital X-ray tomosynthesis,and computed laminography.To get an accurate and reliable reconstruction imag...A precise knowledge of geometry is always pivotal to a 3-D X-ray imaging system,such as computed tomography(CT),digital X-ray tomosynthesis,and computed laminography.To get an accurate and reliable reconstruction image,exact knowledge of geometry is indispensable.Nowadays,geometric calibration has become a necessary step after completing CT system installation.Various geometric calibration methods have been reported with the fast development of 3-D X-ray imaging techniques.In these methods,different measuring methods,calibration phantoms or markers,and calculation algorithms were involved with their respective advantages and disadvantages.This paper reviews the history and current state of geometric calibration methods for different3-D X-ray imaging systems.Various calibration algorithms are presented and summarized,followed by our discussion and outlook.展开更多
基金support from the EPSRC under grants EP/L014289/1 EP/N032888/1 and EP/M014045/1the STFC Global Challenges Network in Batteries and Electrochemical Energy Devices under the grant ST/N002385/1 for facilitation of travelfunding from the Royal Academy of Engineering
文摘Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised due to cost and performance issues, many of which are linked to the microstructure of the porous carbon electrodes used. Here, for the first time, we offer a detailed study of the in situ effects of compression on a commercially available carbon felt electrode. Visualisation of electrode structure us- ing X-ray computed tomography shows the non-linear way that these materials compress and various metrics are used to elucidate the changes in porosity, pore size distribution and tortuosity factor under compressions from 0%-90%.
基金Project supported by the National Basic Research Program of China(Grant No.2012CB825800)the Science Fund for Creative Research Groups,the Knowledge Innovation Program of the Chinese Academy of Sciences(Grant Nos.KJCX2-YW-N42 and Y4545320Y2)the National Natural Science Foundation of China(Grant Nos.11475170,11205157,11305173,11205189,11375225,11321503,11179004,and U1332109)
文摘The relationship between noise variance and spatial resolution in grating-based x-ray phase computed tomography(PCT) imaging is investigated with reverse projection extraction method, and the noise variances of the reconstructed absorption coefficient and refractive index decrement are compared. For the differential phase contrast method, the noise variance in the differential projection images follows the same inverse-square law with spatial resolution as in conventional absorption-based x-ray imaging projections. However, both theoretical analysis and simulations demonstrate that in PCT the noise variance of the reconstructed refractive index decrement scales with spatial resolution follows an inverse linear relationship at fixed slice thickness, while the noise variance of the reconstructed absorption coefficient conforms with the inverse cubic law. The results indicate that, for the same noise variance level, PCT imaging may enable higher spatial resolution than conventional absorption computed tomography(ACT), while ACT benefits more from degraded spatial resolution. This could be a useful guidance in imaging the inner structure of the sample in higher spatial resolution.
基金supported by the National Natural Science Foundation Project(41501283)Beijing Science and Technology Plan Project(Z161100000916012)+2 种基金the National Key Research and Development Program(2017YFD0600901)Special Fund for Beijing Common Construction Projectthe Fundamental Research Funds for the Central Universities(2015ZCQ-GX-04)
文摘The geometric and spatial characteristics of pore structures determine the permeability and water retention of soils, which have important effects on soil functional diversity and ecological restoration. Until recently, there have not been tools and methods to visually and quantitatively describe the characteristics of soil pores. To solve this problem, this research reconstructs the geometry and spatial distribution of soil pores by the marching cubes method, texture mapping method and the ray casting method widely used in literature. The objectives were to explore an optimal method for three-dimensional visualization of soil pore structure by comparing the robustness of the three methods on soil CT images with single pore structure and porosity ranging from low (2–5%) to high (12–18%), and to evaluate the reconstruction performance of the three methods with different geometric features. The results demonstrate that there are aliases (jagged edges) and deficiency at the boundaries of the model reconstructed by the marching cubes method and pore volumes are smaller than the ground truth, whereas the results of the texture mapping method lack the details of pore structures. For all the soil images, the ray casting method is preferable since it better preserves the pore characteristics of the ground truth. Furthermore, the ray casting method produced the best soil pore model with higher rendering speed and lower memory consumption. Therefore, the ray casting method provides a more advanced method for visualization of pore structures and provides an optional technique for the study of the transport of moisture and the exchange of air in soil.
基金Project supported by the National Basic Research Program of China(Grant No.2012CB825800)the National Natural Science Foundation of China(Grant Nos.11205189,11375225,and U1332109)the Knowledge Innovation Program of the Chinese Academy of Sciences(Grant Nos.KJCX2-YW-N42,Y4545320Y2,and 542014IHEPZZBS50659)
文摘A new method in diffraction-enhanced imaging computed tomography (DEI-CT) that follows the idea developed by Chapman et al. [Chapman D, Thomlinson W, Johnston R E, Washburn D, Pisano E, Gmur N, Zhong Z, Menk R, Arfelli F and Sayers D 1997 Phys. Med. BioL 42 2015] in 1997 is proposed in this paper. Merged with a "reverse projections" algorithm, only two sets of projection datasets at two defined orientations of the analyzer crystal are needed to reconstruct the linear absorption coefficient, the decrement of the real part of the refractive index and the linear scattering coefficient of the sample. Not only does this method reduce the delivered dose to the sample without degrading the image quality, but, compared with the existing DEI-CT approaches, it simplifies data-acquisition procedures. Experimental results confirm the reliability of this new method for DEI-CT applications.
基金the National Basic Research Program of China(Grant Nos.2012CB825800 and 2009CB930804)the Key Program of the National Natural Science Foundation of China(Grant Nos.10734070 and 10774144)+1 种基金the National Natural Science Foundation of China(Grant Nos.11205189,10979055,31071909,and 31272358)the Knowledge Innovation Program of the Chinese Academy of Sciences(Grant No.KJCX2-YW-N42)
文摘A penetrating view of the three-dimensional nanostructure of female spermatheca and male flagellum in the species Aleochara verna is obtained with 100-nm resolution using a hard X-ray microscope, which provides a fast noninvasive imaging technology for insect morphology. Through introducing Zernike phase contrast and heavy metal staining, images taken at 8 keV displayed sufficient contrast for observing nanoscale fine structures, such as the spermatheca cochleate duct and the subapex of the flagellum, which have some implications for the study of the sperm transfer process and genital evolution in insects. This work shows that both the spatial resolution and the contrast characteristic of hard X-ray microscopy are quite promising for insect morphology studies and, particularly, provide an attractive alternative to the destructive techniques used for investigating internal soft tissues.
基金supported by the National Natural Science Foundation of China(Grant Nos.11275204,11475175,and 11405175)the China Postdoctoral Science Foundation(Grant No.2017M612097)the Fundamental Research Funds for the Central Universities(Grant No.WK2310000065)
文摘X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping information extraction method reduces system stability and prolongs data acquisition time by several times compared with conventional x-ray absorption- based imaging. The mechanical stepping can be avoided by using a staggered grating, but at the cost of low vertical spatial resolution. In this paper, employing a modified staggered grating and the angular signal radiography, we proposed a single-shot grating-based x-ray differential phase contrast imaging with decent vertical spatial resolution. The theoretical framework was deduced and proved by numerical experiments. Absorption, phase, and scattering computed tomography can be performed without phase stepping. Therefore, we believe this fast and highly stable imaging method with decent resolution would be widely applied in x-ray grating-based phase contrast imaging.
文摘BACKGROUND:The appropriate sequence of different imagings and indications of thoracic computed tomography(TCT)in evaluating chest trauma have not yet been clarified at present.The current study was undertaken to determine the value of chest X-ray(CXR)in detecting chest injuries in patients with blunt trauma.METHODS:A total of 447 patients with blunt thoracic trauma who had been admitted to the emergency department(ED)in the period of 2009–2013 were retrospectively reviewed.The patients met inclusion criteria(age>8 years,blunt injury to the chest,hemodynamically stable,and neurologically intact)and underwent both TCT and upright CXR in the ED.Radiological imagings were re-interpreted after they were collected from the hospital database by two skilled radiologists.RESULTS:Of the 447 patients,309(69.1%)were male.The mean age of the 447 patients was 39.5±19.2(range 9 and 87 years).158(35.3%)patients were injured in motor vehicle accidents(MVA).CXR showed the highest sensitivity in detecting clavicle fractures[95%CI 78.3(63.6–89)]but the lowest in pneuomediastinum[95%CI 11.8(1.5–36.4)].The specificity of CXR was close to 100%in detecting a wide array of entities.CONCLUSION:CXR remains to be the first choice in hemodynamically unstable patients with blunt chest trauma.Moreover,stable patients with normal CXR are candidates who should undergo TCT if significant injury has not been ruled out.
基金supported by the National Natural Science Foundation of China(No.81427803 and 61571256)the Beijing Excellent Talents Training Foundation(No.2013D009004000004)
文摘A precise knowledge of geometry is always pivotal to a 3-D X-ray imaging system,such as computed tomography(CT),digital X-ray tomosynthesis,and computed laminography.To get an accurate and reliable reconstruction image,exact knowledge of geometry is indispensable.Nowadays,geometric calibration has become a necessary step after completing CT system installation.Various geometric calibration methods have been reported with the fast development of 3-D X-ray imaging techniques.In these methods,different measuring methods,calibration phantoms or markers,and calculation algorithms were involved with their respective advantages and disadvantages.This paper reviews the history and current state of geometric calibration methods for different3-D X-ray imaging systems.Various calibration algorithms are presented and summarized,followed by our discussion and outlook.