Dependence of decamethylcyclopentasiloxane (DMCPS) organosilicon dissociation on ionized energy in the energy range of 25 eV to 70 eV is investigated by using a quadrupole mass spectrometry. At the ionized energy be...Dependence of decamethylcyclopentasiloxane (DMCPS) organosilicon dissociation on ionized energy in the energy range of 25 eV to 70 eV is investigated by using a quadrupole mass spectrometry. At the ionized energy below 55 eV, the dissociation of DMCPS is dominant. As the ionized energy is above 55 eV, the DMCPS dissociation achieves the maximum cross section, while the fragments from the DMCPS dissociation can further dissociate, which leads to a different ingredient of fragments. At the lower ionized energy of 25 eV, the main fragments are SiOC2H+, SiCH+, Si+, O+ and CH+ ions, which shows an important effect on the SiCOH low-k film deposition.展开更多
Based on the meson-meson mixing and Regge trajectory, this paper establishes the mass relations which can describe the mass spectrum of 1^1 P1 meson state. Using these mass relations, it obtains the mass of K1B, hi (...Based on the meson-meson mixing and Regge trajectory, this paper establishes the mass relations which can describe the mass spectrum of 1^1 P1 meson state. Using these mass relations, it obtains the mass of K1B, hi (1380) and hc(1P) to be 1358.5MeV, 1468 MeV and 3543.9 MeV, respectively. The results are compared with other theoretical results and should be tested by experiments in the future.展开更多
Tungsten(W)is an important material in tokamak walls and divertors.The W ion charge state distribution and the dynamic behavior of ions play important roles in the investigation of plasma–wall interactions using lase...Tungsten(W)is an important material in tokamak walls and divertors.The W ion charge state distribution and the dynamic behavior of ions play important roles in the investigation of plasma–wall interactions using laser-ablation-based diagnostics such as laser-induced breakdown spectroscopy and laser-induced ablation spectroscopy.In this work,we investigate the temporal and spatial evolutions of differently charged ions in a nanosecond-laser-produced W plasma in vacuum using time-of-flight mass spectroscopy.Ions with different charge states from 1 to 7(W+to W7+)are all observed.The temporal evolutions of the differently charged ions show that ions with higher charge states have higher velocities,indicating that space separation occurs between the differently charged ion groups.Spatially-resolved mass spectroscopy measurements further demonstrate the separation phenomenon.The temporal profile can be accurately fitted by a shifted Maxwell–Boltzmann distribution,and the velocities of the differently charged ions are also obtained from the fittings.It is found that the ion velocities increase continuously from the measured position of 0.75 cm to 2.25 cm away from the target surface,which indicates that the acceleration process lasts through the period of plasma expansion.The acceleration and space separation of the differently charged ions confirm that there is a dynamic plasma sheath in the laser-produced plasma,which provides essential information for the theoretical laser-ablation model with plasma formation and expansion.展开更多
A foil–microchannel plate(MCP)detector,which uses electrostatic lenses and possesses both good position and timing resolutions,has been designed and simulated for beam diagnostics and mass measurements at the next-ge...A foil–microchannel plate(MCP)detector,which uses electrostatic lenses and possesses both good position and timing resolutions,has been designed and simulated for beam diagnostics and mass measurements at the next-generation heavy-ion-beam facility HIAF in China.Characterized by low energy loss and good performances of timing and position measurements,it would be located at focal planes in fragment separator HFRS for position monitoring,beam turning,Bq measurement,and trajectory reconstruction.Moreover,it will benefit the building-up of a magnetic-rigidity–energy-loss–time-offlight(BqDETOF)method at HFRS for high-precision in-flight particle identification of radioactive isotope beams on an event-by-event basis.Most importantly,the detector can be utilized for in-ring TOF and position measurements,beam-line TOF measurements at two achromatic foci,and position measurements at a dispersive focus of HFRS,thus making it possible to use two complementary mass measurement methods[isochronous mass spectrometry at the storage ring SRing and magnetic-rigidity–time-of-flight(BqTOF)at the beam-line HFRS]in one single experimental run.展开更多
A method for analyzing the dynamic energy spectrum of intense pulsed ion beam(IPIB) was proposed.Its influence on beam energy deposition in metal target was studied with IPIB produced by two types of magnetically insu...A method for analyzing the dynamic energy spectrum of intense pulsed ion beam(IPIB) was proposed.Its influence on beam energy deposition in metal target was studied with IPIB produced by two types of magnetically insulated diodes(MID).The emission of IPIB was described with space charge limitation model,and the dynamic energy spectrum was further analyzed with time-of-flight method.IPIBs generated by pulsed accelerators of BIPPAB-450(active MID) and TEMP-4M(passive MID) were studied.The dynamic energy spectrum was used to deduce the power density distribution of IPIB in the target with Monte Carlo simulation and infrared imaging diagnostics.The effect on the distribution and evolution of thermal field induced by the characteristics of IPIB dynamic energy spectrum was discussed.展开更多
Some interferences are often encountered in accelerator mass spectrometry (AMS) measurements, espe-cially for medium-heavy nuclide measurement. It is difficult for online discrimination of the nuclide of interest from...Some interferences are often encountered in accelerator mass spectrometry (AMS) measurements, espe-cially for medium-heavy nuclide measurement. It is difficult for online discrimination of the nuclide of interest from the interfering ones. In order to solve this problem, we developed a method to simulate the experimental spectra of medium-heavy nuclides in AMS measurements. The results obtained from this method are in good agreement with experimental values.展开更多
A single and dual parameter data acquisition, ion beam measurements and control system for accelerator mass spectrometry is described. The system hardware has been constructed with the advantage of the lower cost and ...A single and dual parameter data acquisition, ion beam measurements and control system for accelerator mass spectrometry is described. The system hardware has been constructed with the advantage of the lower cost and higher reliability. It is provided with varieties of functions such as selecting acquisition mode carrying out the multiple display, analyzing data and especially viewing isometric spectrum at different directions. It can also be used for ordinary nuclear spectrum system.展开更多
The full-spectrum least-squares(FSLS) method is introduced to perform quantitative energy-dispersive X-ray fluorescence analysis for unknown solid samples.Based on the conventional least-squares principle, this spectr...The full-spectrum least-squares(FSLS) method is introduced to perform quantitative energy-dispersive X-ray fluorescence analysis for unknown solid samples.Based on the conventional least-squares principle, this spectrum evaluation method is able to obtain the background-corrected and interference-free net peaks, which is significant for quantization analyses. A variety of analytical parameters and functions to describe the features of the fluorescence spectra of pure elements are used and established, such as the mass absorption coefficient, the Gi factor, and fundamental fluorescence formulas. The FSLS iterative program was compiled in the C language. The content of each component should reach the convergence criterion at the end of the calculations. After a basic theory analysis and experimental preparation, 13 national standard soil samples were detected using a spectrometer to test the feasibility of using the algorithm. The results show that the calculated contents of Ti, Fe, Ni, Cu, and Zn have the same changing tendency as the corresponding standard content in the 13 reference samples. Accuracies of 0.35% and 14.03% are obtained, respectively, for Fe and Ti, whose standard concentrations are 8.82% and 0.578%, respectively. However, the calculated results of trace elements (only tens of lg/g) deviate from the standard values. This may be because of measurement accuracy and mutual effects between the elements.展开更多
We theoretically investigate the emission spectrum for a A-type three-level atom trapped in the node of a standing wave. We show that the atomic center-of-mass motion not only directly affects the peak number, peak po...We theoretically investigate the emission spectrum for a A-type three-level atom trapped in the node of a standing wave. We show that the atomic center-of-mass motion not only directly affects the peak number, peak position, and peak height in the atomic emission spectrum, but also influences the effects of the cavity field and the atomic initial state on atomic emission spectrum.展开更多
文摘Dependence of decamethylcyclopentasiloxane (DMCPS) organosilicon dissociation on ionized energy in the energy range of 25 eV to 70 eV is investigated by using a quadrupole mass spectrometry. At the ionized energy below 55 eV, the dissociation of DMCPS is dominant. As the ionized energy is above 55 eV, the DMCPS dissociation achieves the maximum cross section, while the fragments from the DMCPS dissociation can further dissociate, which leads to a different ingredient of fragments. At the lower ionized energy of 25 eV, the main fragments are SiOC2H+, SiCH+, Si+, O+ and CH+ ions, which shows an important effect on the SiCOH low-k film deposition.
文摘Based on the meson-meson mixing and Regge trajectory, this paper establishes the mass relations which can describe the mass spectrum of 1^1 P1 meson state. Using these mass relations, it obtains the mass of K1B, hi (1380) and hc(1P) to be 1358.5MeV, 1468 MeV and 3543.9 MeV, respectively. The results are compared with other theoretical results and should be tested by experiments in the future.
基金supported by the National Key R&D Program of China(No.2017YFE0301304)National Natural Science Foundation of China(No.12005034)the China Postdoctoral Science Foundation(No.2019M661087)supported by the US Department of Energy,Office of Defense Nuclear Nonproliferation Research and Development,under contract number DE-AC02-05CH11231 at the Lawrence Berkeley National Laboratory。
文摘Tungsten(W)is an important material in tokamak walls and divertors.The W ion charge state distribution and the dynamic behavior of ions play important roles in the investigation of plasma–wall interactions using laser-ablation-based diagnostics such as laser-induced breakdown spectroscopy and laser-induced ablation spectroscopy.In this work,we investigate the temporal and spatial evolutions of differently charged ions in a nanosecond-laser-produced W plasma in vacuum using time-of-flight mass spectroscopy.Ions with different charge states from 1 to 7(W+to W7+)are all observed.The temporal evolutions of the differently charged ions show that ions with higher charge states have higher velocities,indicating that space separation occurs between the differently charged ion groups.Spatially-resolved mass spectroscopy measurements further demonstrate the separation phenomenon.The temporal profile can be accurately fitted by a shifted Maxwell–Boltzmann distribution,and the velocities of the differently charged ions are also obtained from the fittings.It is found that the ion velocities increase continuously from the measured position of 0.75 cm to 2.25 cm away from the target surface,which indicates that the acceleration process lasts through the period of plasma expansion.The acceleration and space separation of the differently charged ions confirm that there is a dynamic plasma sheath in the laser-produced plasma,which provides essential information for the theoretical laser-ablation model with plasma formation and expansion.
基金supported by the National Natural Science Foundation of China(Nos.11605248,11605249,11605267,and 11805032.)
文摘A foil–microchannel plate(MCP)detector,which uses electrostatic lenses and possesses both good position and timing resolutions,has been designed and simulated for beam diagnostics and mass measurements at the next-generation heavy-ion-beam facility HIAF in China.Characterized by low energy loss and good performances of timing and position measurements,it would be located at focal planes in fragment separator HFRS for position monitoring,beam turning,Bq measurement,and trajectory reconstruction.Moreover,it will benefit the building-up of a magnetic-rigidity–energy-loss–time-offlight(BqDETOF)method at HFRS for high-precision in-flight particle identification of radioactive isotope beams on an event-by-event basis.Most importantly,the detector can be utilized for in-ring TOF and position measurements,beam-line TOF measurements at two achromatic foci,and position measurements at a dispersive focus of HFRS,thus making it possible to use two complementary mass measurement methods[isochronous mass spectrometry at the storage ring SRing and magnetic-rigidity–time-of-flight(BqTOF)at the beam-line HFRS]in one single experimental run.
基金supported by the National Natural Science Foundation of China(No.11175012)the National Magnetic Confinement Fusion Program(No.2013GB109004)
文摘A method for analyzing the dynamic energy spectrum of intense pulsed ion beam(IPIB) was proposed.Its influence on beam energy deposition in metal target was studied with IPIB produced by two types of magnetically insulated diodes(MID).The emission of IPIB was described with space charge limitation model,and the dynamic energy spectrum was further analyzed with time-of-flight method.IPIBs generated by pulsed accelerators of BIPPAB-450(active MID) and TEMP-4M(passive MID) were studied.The dynamic energy spectrum was used to deduce the power density distribution of IPIB in the target with Monte Carlo simulation and infrared imaging diagnostics.The effect on the distribution and evolution of thermal field induced by the characteristics of IPIB dynamic energy spectrum was discussed.
基金Supported by the National Natural Science Foundation of China (No.10175094) and the Science Foundation of Guangxi University (X022013)
文摘Some interferences are often encountered in accelerator mass spectrometry (AMS) measurements, espe-cially for medium-heavy nuclide measurement. It is difficult for online discrimination of the nuclide of interest from the interfering ones. In order to solve this problem, we developed a method to simulate the experimental spectra of medium-heavy nuclides in AMS measurements. The results obtained from this method are in good agreement with experimental values.
文摘A single and dual parameter data acquisition, ion beam measurements and control system for accelerator mass spectrometry is described. The system hardware has been constructed with the advantage of the lower cost and higher reliability. It is provided with varieties of functions such as selecting acquisition mode carrying out the multiple display, analyzing data and especially viewing isometric spectrum at different directions. It can also be used for ordinary nuclear spectrum system.
基金supported by the National Key R&D Project of China(No.2017YFC0602100)the National Natural Science Foundation of China(No.41774147)Sichuan Science and Technology Support Program(No.2015GZ0272)
文摘The full-spectrum least-squares(FSLS) method is introduced to perform quantitative energy-dispersive X-ray fluorescence analysis for unknown solid samples.Based on the conventional least-squares principle, this spectrum evaluation method is able to obtain the background-corrected and interference-free net peaks, which is significant for quantization analyses. A variety of analytical parameters and functions to describe the features of the fluorescence spectra of pure elements are used and established, such as the mass absorption coefficient, the Gi factor, and fundamental fluorescence formulas. The FSLS iterative program was compiled in the C language. The content of each component should reach the convergence criterion at the end of the calculations. After a basic theory analysis and experimental preparation, 13 national standard soil samples were detected using a spectrometer to test the feasibility of using the algorithm. The results show that the calculated contents of Ti, Fe, Ni, Cu, and Zn have the same changing tendency as the corresponding standard content in the 13 reference samples. Accuracies of 0.35% and 14.03% are obtained, respectively, for Fe and Ti, whose standard concentrations are 8.82% and 0.578%, respectively. However, the calculated results of trace elements (only tens of lg/g) deviate from the standard values. This may be because of measurement accuracy and mutual effects between the elements.
文摘We theoretically investigate the emission spectrum for a A-type three-level atom trapped in the node of a standing wave. We show that the atomic center-of-mass motion not only directly affects the peak number, peak position, and peak height in the atomic emission spectrum, but also influences the effects of the cavity field and the atomic initial state on atomic emission spectrum.