With the increase of underground engineering construction depth,the phenomenon of surrounding rock sudden failure caused by supporting structure failure occurs frequently.The conventional unloading con-fining pressure...With the increase of underground engineering construction depth,the phenomenon of surrounding rock sudden failure caused by supporting structure failure occurs frequently.The conventional unloading con-fining pressure(CUCP)test cannot simulate the plastic yielding and instantaneous unloading process of supporting structure to rock.Thus,a high stress loading-instantaneous unloading confining pressure(HSL-IUCP)test method was proposed and applied by considering bolt’s fracture under stress.The wall thickness of confining pressure plates and the material of bolts were changed to realize different confin-ing pressure loading stiffness(CPLS)and lateral maximum allowable deformation(LMAD).The superio-rity of HSL-ICPU method is verified compared with CUCP.The rock failure mechanism caused by sudden failure of supporting structure is obtained.The results show that when CPLS increases from 1.35 to 2.33 GN/m,rock’s peak strength and elastic modulus increase by 25.18%and 23.70%,respectively.The fracture characteristics change from tensile failure to tensile-shear mixed failure.When LMAD decreases from 0.40 to 0.16 mm,rock’s residual strength,peak strain,and residual strain decrease by 91.80%,16.94%,and 21.92%,respectively,and post-peak drop modulus increases by 140.47%.The test results obtained by this method are closer to rock’s real mechanical response characteristics compared with CUCP.展开更多
The difficulties associated with performing direct compression strength tests on rocks lead to the development of indirect test methods for the rock strength assessment. Indirect test methods are simple, more economic...The difficulties associated with performing direct compression strength tests on rocks lead to the development of indirect test methods for the rock strength assessment. Indirect test methods are simple, more economical, less time-consuming, and easily adaptable to the field. The main aim of this study was to derive correlations between direct and indirect test methods for basalt and rhyolite rock types from Carlin trend deposits in Nevada. In the destructive methods, point load index, block punch index, and splitting tensile strength tests are performed. In the non-destructive methods, Schmidt hammer and ultrasonic pulse velocity tests are performed. Correlations between the direct and indirect compression strength tests are developed using linear and nonlinear regression analysis methods. The results show that the splitting tensile strength has the best correlation with the uniaxial compression strength.Furthermore, the Poisson's ratio has no correlation with any of the direct and indirect test results.展开更多
Firstly, relevant stress properties of millisecond level breaking process and microsecond level commutation process of hybrid HVDC circuit breaker are studied in detail on the basis of the analysis for the application...Firstly, relevant stress properties of millisecond level breaking process and microsecond level commutation process of hybrid HVDC circuit breaker are studied in detail on the basis of the analysis for the application environment and topological structure and operating principles of hybrid circuit breakers, and key stress parameters in transient state process of two time dimensions are extracted. The established digital simulation circuit for PSCAD/EMTDC device-level operation of the circuit breaker has verified the stress properties of millisecond level breaking process and microsecond level commutation process. Then, equivalent test method, circuits and parameters based on LC power supply are proposed on the basis of stress extraction. Finally, the results of implemented breaking tests for complete 200 kV circuit breaker, 100 kV and 50 kV circuit breaker units, as well as single power electronic module have verified the accuracy of the simulation circuit and mathematical analysis. The result of this paper can be a guide to electrical structure and test system design of hybrid HVDC circuit breaker.展开更多
The depth of penetration(DOP)method is a well-known ballistic test method for characterisation and ranking of ceramic armour materials.The ceramic tile is bonded to a backing material of semi-infinite thickness,and th...The depth of penetration(DOP)method is a well-known ballistic test method for characterisation and ranking of ceramic armour materials.The ceramic tile is bonded to a backing material of semi-infinite thickness,and the penetration depth of the projectile gives a measure of the performance of the ceramic.There is,however,an inherent variability in the results from this test method.In this work,the accuracy and the variability of the DOP method has been investigated in a round robin exercise.Six ballistic test centres took part in the exercise.A test protocol was developed,in which the threat type(projectile and impact conditions)and a procedure on how to prepare the targets were specified.The targets consisted of alumina tiles of two different thicknesses that were bonded to polycarbonate backing cubes.Two different 7.62 mm armour piercing projectiles were employed;one with a hard steel core and one with a tungsten carbide core.The projectiles and the other materials all came from single material batches in order to avoid batch-to-batch variations in material properties.These materials were distributed between the ballistic test centres.The test results of the different ballistic test facilities were collected and compared.There was not a lot of variation between the average DOP values obtained at each laboratory,but the variation in penetration depth between shots was high.The consequence of this variation may be less confidence in the test results,and a statistical method was used to evaluate the required number of tests that are sufficient to obtain an average result with high confidence.In most cases,the required number of tests is much higher than what is practically feasible.This work was conducted as part of the European Defence Agency-project CERAMBALL.展开更多
Since 2009,the Mine Safety and Health Administration(MSHA)has required mines to install refuge alternatives(RAs)in underground coal mines.One of the biggest concerns with occupied RAs is the possible severity of the r...Since 2009,the Mine Safety and Health Administration(MSHA)has required mines to install refuge alternatives(RAs)in underground coal mines.One of the biggest concerns with occupied RAs is the possible severity of the resulting thermal environment.In 30 CFR 7.504,the maximum allowable apparent temperature(AT)for an occupied RA is specified as 35℃(95°F).Manufacturers must conduct heat/humidity tests to demonstrate that their RAs meet the 35℃(95°F)AT limit.For these tests,heat input devices are used to input the metabolic heat of actual miners.A wide variety of test methods,sensors,and heat input devices could be used when conducting such tests.Since 2012,the National Institute for Occupational Safety and Health(NIOSH)has conducted over thirty 96-hour heat/humidity tests on four different RAs.This paper discusses the test equipment and procedures used during these investigations.This information is useful for RA manufacturers conducting RA heat/humidity tests,for other researchers investigating RA heat/humidity buildup,and for those who need to assess the thermal environment of any confined space where people may be trapped or are seeking refuge.展开更多
1 Development of UHVDC transmission capabilities The economical development of China is closely connected with safe and reliable power supply.Load centers e.g.in central and eastern China need huge amounts of electric...1 Development of UHVDC transmission capabilities The economical development of China is closely connected with safe and reliable power supply.Load centers e.g.in central and eastern China need huge amounts of electrical power.Available energy resources and consumption areas are often distributed inverse.As a consequence it is necessary to import electrical power to load center areas in an economic and efficient way.展开更多
Gemstones have fascinated mankind forever,and people traveled far to find them.The Silk Road is one of the most traditional trade routes in the middle ages that was used to bring the precious stones to the European ma...Gemstones have fascinated mankind forever,and people traveled far to find them.The Silk Road is one of the most traditional trade routes in the middle ages that was used to bring the precious stones to the European market.Later,emeralds from Colombia were shipped via the ocean to the Old World.展开更多
In a test of the weak equivalence principle (WEP) with a rotating torsion pendulum, it is important to estimate the amplitude of the modulation signal with high precision. We use a torsional filter to remove the fre...In a test of the weak equivalence principle (WEP) with a rotating torsion pendulum, it is important to estimate the amplitude of the modulation signal with high precision. We use a torsional filter to remove the free oscillation signal and employ the correlation method to estimate the amplitude of the modulation signal. The data analysis of an experiment shows that the uncertainties of amplitude components of the modulation signal obtained by the correlation method are in agreement with those due to white noise. The power spectral density of the modulation signal obtained by the correlation method is about one order higher than the thermal noise limit. It indicates that the correlation method is an effective way to estimate the amplitude of the modulation signal and it is instructive to conduct a high-accuracy WEP test.展开更多
The anchor stress extent of a prestress anchor cable project has a direct relation with the project safety and performance. Prestressed tensioning method is a kind of nondestructive testing method, by which a reverse ...The anchor stress extent of a prestress anchor cable project has a direct relation with the project safety and performance. Prestressed tensioning method is a kind of nondestructive testing method, by which a reverse stretching load is applied on the external exposure section of anchor cable under construction or in service, and then the elongation variation of stress bars is measured to determine the anchor stress. We elaborated the theory and testing mechanism of prestressed tensioning method, and systematically studied key issues during the prestressed tensioning process of anchor cable by using physical model test, including the composition of tension stress-elongation curve, the variation of anchor stress, the compensation of locked anchor stress, and the judgment of anchor stress, and verified the theory feasibility of prestressed tensioning method. A case study on slope anchor cable of one highway project was conducted to further discuss on the test method, operation procedures and judgment of prestressed tensioning method on obtaining anchor stress, and then the test data of three situations were analyzed. The result provides a theoretical basis and technical base for the application of prestressed tensioning method to the evaluation of construction quality and operation conditions of anchor cable project.展开更多
To estimate the life of vacuum fluorescent display (VFD) more accurately and reduce test time and cost, four constant stress accelerated life tests (CSALTs) were conducted on an accelerated life test model. In the...To estimate the life of vacuum fluorescent display (VFD) more accurately and reduce test time and cost, four constant stress accelerated life tests (CSALTs) were conducted on an accelerated life test model. In the model, statistical analysis of test data is achieved by applying lognormal function to describe the life distribution, and least square method (LSM) to calculate the mean value and the standard deviation of logarithm. As a result, the accelerated life equation was obtained, and then a self-developed software was developed to predict the VFD life. The data analysis results demonstrate that the VFD life submits to lognormal distribution, that the accelerated model meets the linear Arrhenius equation, and that the precise accelerated parameter makes it possible to acquire the life information of VFD within one month.展开更多
The wireline formation tester (WFT) is an important tool for formation evaluation, such as calculating the formation pressure and permeability, identifying the fluid type, and determining the interface between oil a...The wireline formation tester (WFT) is an important tool for formation evaluation, such as calculating the formation pressure and permeability, identifying the fluid type, and determining the interface between oil and water. However, in a low porosity and low permeability formation, the supercharge pressure effect exists, since the mudcake has a poor sealing ability. The mudcake cannot isolate the hydrostatic pressure of the formation around the borehole and the mud seeps into the formations, leading to inaccurate formation pressure measurement. At the same time, the tool can be easily stuck in the low porosity/low permeability formation due to the long waiting and testing time. We present a method for determining the minimum testing time for the wireline formation tester. The pressure distribution of the mudcake and the formation were respectively calculated with the finite element method (FEM). The radius of the influence of mud pressure was also computed, and the minimum testing time in low porosity/low permeability formations was determined within a range of values for different formation permeabilities. The determination of the minimum testing time ensures an accurate formation pressure measurement and minimizes possible accidents due to long waiting and testing time.展开更多
The finite volume method has been successfully applied in several engineering fields and has shown outstanding performance in fluid dynamics simulation. In this paper, the general framework for the simulation ofnear-w...The finite volume method has been successfully applied in several engineering fields and has shown outstanding performance in fluid dynamics simulation. In this paper, the general framework for the simulation ofnear-wellbore systems using the finite volume method is described. The mathematical model and the numerical model developed by the authors are presented and discussed. A radial geometry in the vertical plane was implemented so as to thoroughly describe near-wellbore phenomena. The model was then used to simulate injection tests in an oil reservoir through a horizontal well and proved very powerful to correctly reproduce the transient pressure behavior. The reason for this is the robustness of the method, which is independent of the gridding options because the discretization is performed in the physical space. The model is able to describe the phenomena taking place in the reservoir even in complex situations, i.e. in the presence of heterogeneities and permeability barriers, demonstrating the flexibility of the finite volume method when simulating non-conventional tests. The results are presented in comparison with those obtained with the finite difference numerical approach and with analytical methods, if possible.展开更多
Two modeling methods of the root insert for wind turbine blade are presented,i.e.,the local mesh optimization method(LMOM)and the global modeling method(GMM).Based on the optimized mesh of the local model for the meta...Two modeling methods of the root insert for wind turbine blade are presented,i.e.,the local mesh optimization method(LMOM)and the global modeling method(GMM).Based on the optimized mesh of the local model for the metal contact interface,LMOM is proposed to analyze the load path and stress distribution characteristics,while GMM is used to calculate and analyze the stress distribution characteristics of the resin layer established between the bushing and composite layers of root insert.To validate the GMM,a tension test is carried out.The result successfully shows that the shear strain expresses a similar strain distribution tendency with the GMM′s results.展开更多
For our research, a new hybrid experimental-computational method is presented. We applied a least squares fitting method (LSFM) to reconstruct the wood moisture content (WMC) from the data measured with a planar c...For our research, a new hybrid experimental-computational method is presented. We applied a least squares fitting method (LSFM) to reconstruct the wood moisture content (WMC) from the data measured with a planar capacitance sensor. A boundary element method (BEM) was used to compute the relationship between capacitance and the dielectric constant. A functional relationship between MC and the dielectric constant was identified by LSFM. The agreement of this final computation result with the experimental data indicates that this method can be used to estimate the WMC quickly and effectively with engineering analysis. Compared with popular statistical methods, a large number of experiments are avoided, some costs of testing are reduced and the efficiency of testing is enhanced.展开更多
基金the National Natural Science Foundation of China(Nos.52374218,52174122 and 52374094)Outstanding Youth Fund of Shandong Natural Science Foundation(No.ZR2022YQ49)Taishan Scholar Project in Shandong Province(Nos.tspd20210313 and tsqn202211150).
文摘With the increase of underground engineering construction depth,the phenomenon of surrounding rock sudden failure caused by supporting structure failure occurs frequently.The conventional unloading con-fining pressure(CUCP)test cannot simulate the plastic yielding and instantaneous unloading process of supporting structure to rock.Thus,a high stress loading-instantaneous unloading confining pressure(HSL-IUCP)test method was proposed and applied by considering bolt’s fracture under stress.The wall thickness of confining pressure plates and the material of bolts were changed to realize different confin-ing pressure loading stiffness(CPLS)and lateral maximum allowable deformation(LMAD).The superio-rity of HSL-ICPU method is verified compared with CUCP.The rock failure mechanism caused by sudden failure of supporting structure is obtained.The results show that when CPLS increases from 1.35 to 2.33 GN/m,rock’s peak strength and elastic modulus increase by 25.18%and 23.70%,respectively.The fracture characteristics change from tensile failure to tensile-shear mixed failure.When LMAD decreases from 0.40 to 0.16 mm,rock’s residual strength,peak strain,and residual strain decrease by 91.80%,16.94%,and 21.92%,respectively,and post-peak drop modulus increases by 140.47%.The test results obtained by this method are closer to rock’s real mechanical response characteristics compared with CUCP.
基金CDC/NIOSH for their partial funding of this work
文摘The difficulties associated with performing direct compression strength tests on rocks lead to the development of indirect test methods for the rock strength assessment. Indirect test methods are simple, more economical, less time-consuming, and easily adaptable to the field. The main aim of this study was to derive correlations between direct and indirect test methods for basalt and rhyolite rock types from Carlin trend deposits in Nevada. In the destructive methods, point load index, block punch index, and splitting tensile strength tests are performed. In the non-destructive methods, Schmidt hammer and ultrasonic pulse velocity tests are performed. Correlations between the direct and indirect compression strength tests are developed using linear and nonlinear regression analysis methods. The results show that the splitting tensile strength has the best correlation with the uniaxial compression strength.Furthermore, the Poisson's ratio has no correlation with any of the direct and indirect test results.
基金supported by SGCC Scientific and Technological Project(52110116004W)
文摘Firstly, relevant stress properties of millisecond level breaking process and microsecond level commutation process of hybrid HVDC circuit breaker are studied in detail on the basis of the analysis for the application environment and topological structure and operating principles of hybrid circuit breakers, and key stress parameters in transient state process of two time dimensions are extracted. The established digital simulation circuit for PSCAD/EMTDC device-level operation of the circuit breaker has verified the stress properties of millisecond level breaking process and microsecond level commutation process. Then, equivalent test method, circuits and parameters based on LC power supply are proposed on the basis of stress extraction. Finally, the results of implemented breaking tests for complete 200 kV circuit breaker, 100 kV and 50 kV circuit breaker units, as well as single power electronic module have verified the accuracy of the simulation circuit and mathematical analysis. The result of this paper can be a guide to electrical structure and test system design of hybrid HVDC circuit breaker.
基金conducted as part of the European Defence Agency-project CERAMBALL,contract number B 1091 GEM1 GP
文摘The depth of penetration(DOP)method is a well-known ballistic test method for characterisation and ranking of ceramic armour materials.The ceramic tile is bonded to a backing material of semi-infinite thickness,and the penetration depth of the projectile gives a measure of the performance of the ceramic.There is,however,an inherent variability in the results from this test method.In this work,the accuracy and the variability of the DOP method has been investigated in a round robin exercise.Six ballistic test centres took part in the exercise.A test protocol was developed,in which the threat type(projectile and impact conditions)and a procedure on how to prepare the targets were specified.The targets consisted of alumina tiles of two different thicknesses that were bonded to polycarbonate backing cubes.Two different 7.62 mm armour piercing projectiles were employed;one with a hard steel core and one with a tungsten carbide core.The projectiles and the other materials all came from single material batches in order to avoid batch-to-batch variations in material properties.These materials were distributed between the ballistic test centres.The test results of the different ballistic test facilities were collected and compared.There was not a lot of variation between the average DOP values obtained at each laboratory,but the variation in penetration depth between shots was high.The consequence of this variation may be less confidence in the test results,and a statistical method was used to evaluate the required number of tests that are sufficient to obtain an average result with high confidence.In most cases,the required number of tests is much higher than what is practically feasible.This work was conducted as part of the European Defence Agency-project CERAMBALL.
文摘Since 2009,the Mine Safety and Health Administration(MSHA)has required mines to install refuge alternatives(RAs)in underground coal mines.One of the biggest concerns with occupied RAs is the possible severity of the resulting thermal environment.In 30 CFR 7.504,the maximum allowable apparent temperature(AT)for an occupied RA is specified as 35℃(95°F).Manufacturers must conduct heat/humidity tests to demonstrate that their RAs meet the 35℃(95°F)AT limit.For these tests,heat input devices are used to input the metabolic heat of actual miners.A wide variety of test methods,sensors,and heat input devices could be used when conducting such tests.Since 2012,the National Institute for Occupational Safety and Health(NIOSH)has conducted over thirty 96-hour heat/humidity tests on four different RAs.This paper discusses the test equipment and procedures used during these investigations.This information is useful for RA manufacturers conducting RA heat/humidity tests,for other researchers investigating RA heat/humidity buildup,and for those who need to assess the thermal environment of any confined space where people may be trapped or are seeking refuge.
文摘1 Development of UHVDC transmission capabilities The economical development of China is closely connected with safe and reliable power supply.Load centers e.g.in central and eastern China need huge amounts of electrical power.Available energy resources and consumption areas are often distributed inverse.As a consequence it is necessary to import electrical power to load center areas in an economic and efficient way.
文摘Gemstones have fascinated mankind forever,and people traveled far to find them.The Silk Road is one of the most traditional trade routes in the middle ages that was used to bring the precious stones to the European market.Later,emeralds from Colombia were shipped via the ocean to the Old World.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11575160,91636221,and 11605065)
文摘In a test of the weak equivalence principle (WEP) with a rotating torsion pendulum, it is important to estimate the amplitude of the modulation signal with high precision. We use a torsional filter to remove the free oscillation signal and employ the correlation method to estimate the amplitude of the modulation signal. The data analysis of an experiment shows that the uncertainties of amplitude components of the modulation signal obtained by the correlation method are in agreement with those due to white noise. The power spectral density of the modulation signal obtained by the correlation method is about one order higher than the thermal noise limit. It indicates that the correlation method is an effective way to estimate the amplitude of the modulation signal and it is instructive to conduct a high-accuracy WEP test.
基金Funded by the Science and Technolog Program of Ministry of Transport of P.R.China(No.2012318352100)
文摘The anchor stress extent of a prestress anchor cable project has a direct relation with the project safety and performance. Prestressed tensioning method is a kind of nondestructive testing method, by which a reverse stretching load is applied on the external exposure section of anchor cable under construction or in service, and then the elongation variation of stress bars is measured to determine the anchor stress. We elaborated the theory and testing mechanism of prestressed tensioning method, and systematically studied key issues during the prestressed tensioning process of anchor cable by using physical model test, including the composition of tension stress-elongation curve, the variation of anchor stress, the compensation of locked anchor stress, and the judgment of anchor stress, and verified the theory feasibility of prestressed tensioning method. A case study on slope anchor cable of one highway project was conducted to further discuss on the test method, operation procedures and judgment of prestressed tensioning method on obtaining anchor stress, and then the test data of three situations were analyzed. The result provides a theoretical basis and technical base for the application of prestressed tensioning method to the evaluation of construction quality and operation conditions of anchor cable project.
基金Shanghai Municipal Natural Science Foun-dation (NO.09ZR1413000)Undergraduate Education High-land Construction Project of ShanghaiKey Technology R&D Program of Shanghai Municipality (No.08160510600)
文摘To estimate the life of vacuum fluorescent display (VFD) more accurately and reduce test time and cost, four constant stress accelerated life tests (CSALTs) were conducted on an accelerated life test model. In the model, statistical analysis of test data is achieved by applying lognormal function to describe the life distribution, and least square method (LSM) to calculate the mean value and the standard deviation of logarithm. As a result, the accelerated life equation was obtained, and then a self-developed software was developed to predict the VFD life. The data analysis results demonstrate that the VFD life submits to lognormal distribution, that the accelerated model meets the linear Arrhenius equation, and that the precise accelerated parameter makes it possible to acquire the life information of VFD within one month.
文摘The wireline formation tester (WFT) is an important tool for formation evaluation, such as calculating the formation pressure and permeability, identifying the fluid type, and determining the interface between oil and water. However, in a low porosity and low permeability formation, the supercharge pressure effect exists, since the mudcake has a poor sealing ability. The mudcake cannot isolate the hydrostatic pressure of the formation around the borehole and the mud seeps into the formations, leading to inaccurate formation pressure measurement. At the same time, the tool can be easily stuck in the low porosity/low permeability formation due to the long waiting and testing time. We present a method for determining the minimum testing time for the wireline formation tester. The pressure distribution of the mudcake and the formation were respectively calculated with the finite element method (FEM). The radius of the influence of mud pressure was also computed, and the minimum testing time in low porosity/low permeability formations was determined within a range of values for different formation permeabilities. The determination of the minimum testing time ensures an accurate formation pressure measurement and minimizes possible accidents due to long waiting and testing time.
文摘The finite volume method has been successfully applied in several engineering fields and has shown outstanding performance in fluid dynamics simulation. In this paper, the general framework for the simulation ofnear-wellbore systems using the finite volume method is described. The mathematical model and the numerical model developed by the authors are presented and discussed. A radial geometry in the vertical plane was implemented so as to thoroughly describe near-wellbore phenomena. The model was then used to simulate injection tests in an oil reservoir through a horizontal well and proved very powerful to correctly reproduce the transient pressure behavior. The reason for this is the robustness of the method, which is independent of the gridding options because the discretization is performed in the physical space. The model is able to describe the phenomena taking place in the reservoir even in complex situations, i.e. in the presence of heterogeneities and permeability barriers, demonstrating the flexibility of the finite volume method when simulating non-conventional tests. The results are presented in comparison with those obtained with the finite difference numerical approach and with analytical methods, if possible.
基金supported jointly by the National Basic Research Program of China("973"Program)(No2014CB046200)the National Science Foundation of Jiangsu Province(No.BK2014059)+1 种基金the Priority Academic Program Development of Jiangsu Higher Education Institutionsthe National Natural Science Foundation of China(No.11172135)
文摘Two modeling methods of the root insert for wind turbine blade are presented,i.e.,the local mesh optimization method(LMOM)and the global modeling method(GMM).Based on the optimized mesh of the local model for the metal contact interface,LMOM is proposed to analyze the load path and stress distribution characteristics,while GMM is used to calculate and analyze the stress distribution characteristics of the resin layer established between the bushing and composite layers of root insert.To validate the GMM,a tension test is carried out.The result successfully shows that the shear strain expresses a similar strain distribution tendency with the GMM′s results.
基金supported by the Central University Basic Research Professional Expenses Special Foundation of Harbin Engineering University (Grant No. HEUCFL10101109)
文摘For our research, a new hybrid experimental-computational method is presented. We applied a least squares fitting method (LSFM) to reconstruct the wood moisture content (WMC) from the data measured with a planar capacitance sensor. A boundary element method (BEM) was used to compute the relationship between capacitance and the dielectric constant. A functional relationship between MC and the dielectric constant was identified by LSFM. The agreement of this final computation result with the experimental data indicates that this method can be used to estimate the WMC quickly and effectively with engineering analysis. Compared with popular statistical methods, a large number of experiments are avoided, some costs of testing are reduced and the efficiency of testing is enhanced.