Temperature control curve is the key to achieving temperature control and crack prevention of high concrete dam during construction,and its rationality depends on the accurate measurement of temperature stress.With th...Temperature control curve is the key to achieving temperature control and crack prevention of high concrete dam during construction,and its rationality depends on the accurate measurement of temperature stress.With the simulation testing machine for the temperature stress,in the present study,we carried out the deformation process tests of concrete under three temperature curves:convex,straight and concave.Besides,we not only measured the early-age elastic modulus,creep parameters and stress process,but also proposed the preferred type.The results show that at early age,higher temperature always leads to greater elastic modulus and smaller creep.However,the traditional indoor experiments have underestimated the elastic modulus and creep development at early age,which makes the calculated value of temperature stress too small,thus increasing the cracking risk.In this study,the stress values of the three curves calculated based on the strain and early-age parameters are in good agreement with the temperature stress measured by the temperature stress testing machine,which verifies the method accuracy.When the temperature changes along the concave curve,the law of stress development is in consistent with that of strength.Under this condition,the stress fluctuation is small and the crack prevention safety of the concave type is higher,so the concave type is better.The test results provide a reliable basis and support for temperature control curve design and optimization of concrete dams.展开更多
The equivalent circuit with complex physical constants for a piezoelectric ceramic in thickness mode is established. In the equivalent circuit, electric components (equivalent circuit parameters) are connected to re...The equivalent circuit with complex physical constants for a piezoelectric ceramic in thickness mode is established. In the equivalent circuit, electric components (equivalent circuit parameters) are connected to real and imaginary parts of complex physical coefficients of piezoelectric materials. Based on definitions of dissipation factors, three of them (dielectric, elastic and piezoelectric dissipation factors) are represented by equivalent circuit parameters. Since the equivalent circuit parameters are detectable, the dissipation factors can be easily obtained. In the experiments, the temperature and the stress responses of the three dissipation factors are measured.展开更多
基金National Key R&D Plan Project(No.2021YFC3090102)。
文摘Temperature control curve is the key to achieving temperature control and crack prevention of high concrete dam during construction,and its rationality depends on the accurate measurement of temperature stress.With the simulation testing machine for the temperature stress,in the present study,we carried out the deformation process tests of concrete under three temperature curves:convex,straight and concave.Besides,we not only measured the early-age elastic modulus,creep parameters and stress process,but also proposed the preferred type.The results show that at early age,higher temperature always leads to greater elastic modulus and smaller creep.However,the traditional indoor experiments have underestimated the elastic modulus and creep development at early age,which makes the calculated value of temperature stress too small,thus increasing the cracking risk.In this study,the stress values of the three curves calculated based on the strain and early-age parameters are in good agreement with the temperature stress measured by the temperature stress testing machine,which verifies the method accuracy.When the temperature changes along the concave curve,the law of stress development is in consistent with that of strength.Under this condition,the stress fluctuation is small and the crack prevention safety of the concave type is higher,so the concave type is better.The test results provide a reliable basis and support for temperature control curve design and optimization of concrete dams.
基金Project supported by the National Natural Science Foundation of China (Grant No 50278098).
文摘The equivalent circuit with complex physical constants for a piezoelectric ceramic in thickness mode is established. In the equivalent circuit, electric components (equivalent circuit parameters) are connected to real and imaginary parts of complex physical coefficients of piezoelectric materials. Based on definitions of dissipation factors, three of them (dielectric, elastic and piezoelectric dissipation factors) are represented by equivalent circuit parameters. Since the equivalent circuit parameters are detectable, the dissipation factors can be easily obtained. In the experiments, the temperature and the stress responses of the three dissipation factors are measured.