Magnetized target fusion is an alternative method to fulfill the goal of controlled fusion, which combines advan- tages of both magnetic confinement fusion and inertial confinement fusion since its parameter space lie...Magnetized target fusion is an alternative method to fulfill the goal of controlled fusion, which combines advan- tages of both magnetic confinement fusion and inertial confinement fusion since its parameter space lies between the two traditional ways. Field reversed configuration (FFtC) is a good candidate of magnetized targets due to its translatable, compressible, high /3 and high energy density properties. Dynamic formation process of high density FFtC is observed on the YingGuang 1 device for the first time in China. The evolution of a magnetic field is detected with magnetic probes, and the compression process can be clearly seen from images taken with a high-speed multi-frame CCD camera. The process is also studied with two-dimensional magneto hydrodynamic code MPF-2D theoretically, and the results agree well with the experiment. Combining the experimental data and the theoretical analysis, the length of the formed FRC is about 39 cm, the diameter is about 2-2. 7cm, the average density is 1.3× 1016 cm-3, and the average temperature is 137eV.展开更多
基金Supported by the Development Foundation of China Academy of Engineering Physics under Grant No 2011B0402009the National Natural Science Foundation of China under Grant Nos 11375163,11575029 and 11175028
文摘Magnetized target fusion is an alternative method to fulfill the goal of controlled fusion, which combines advan- tages of both magnetic confinement fusion and inertial confinement fusion since its parameter space lies between the two traditional ways. Field reversed configuration (FFtC) is a good candidate of magnetized targets due to its translatable, compressible, high /3 and high energy density properties. Dynamic formation process of high density FFtC is observed on the YingGuang 1 device for the first time in China. The evolution of a magnetic field is detected with magnetic probes, and the compression process can be clearly seen from images taken with a high-speed multi-frame CCD camera. The process is also studied with two-dimensional magneto hydrodynamic code MPF-2D theoretically, and the results agree well with the experiment. Combining the experimental data and the theoretical analysis, the length of the formed FRC is about 39 cm, the diameter is about 2-2. 7cm, the average density is 1.3× 1016 cm-3, and the average temperature is 137eV.