The process of ground vehicle dynamic gravimetry is inevitably affected by the carrier’s maneuvering acceleration,which makes the result contain a large amount of dynamic error.In this paper,we propose a dynamic erro...The process of ground vehicle dynamic gravimetry is inevitably affected by the carrier’s maneuvering acceleration,which makes the result contain a large amount of dynamic error.In this paper,we propose a dynamic error suppression method of gravimetry based on the high-precision acquisition of external velocity for compensating the horizontal error of the inertial plat-form.On the basis of platform gravity measurement,firstly,the dynamic performance of the system is enhanced by optimizing the horizontal damping network of the inertial platform and selecting its parameter.Secondly,an improved federal Kalman filtering algorithm and a fault diagnosis method are designed using strapdown inertial navigation system(SINS),odometer(OD),and laser Doppler velocimeter(LDV).Simulation validates that these methods can improve the accuracy and robustness of the external velocity acquisition.Three survey lines are selected in Tianjin,China,for the gravimetry experiments with different maneuvering levels,and the results demonstrate that after dynamic error suppression,the internal coincidence accuracies of smooth and uniform operation,obvious acceleration and deceleration operation,and high-dynamic operation are improved by 70.2%,73.6%,and 77.9%to reach 0.81 mGal,1.30 mGal,and 1.94 mGal,respectively,and the external coinci-dence accuracies during smooth and uniform operation are improved by 48.6%up to 1.66 mGal.It is shown that the pro-posed method can effectively suppress the dynamic error,and that the accuracy improvement increases with carrier maneuver-ability.However,the amount of residual error that can not be entirely eliminated increases as well,so the ground vehicle dynamic gravimetry should be maintained in the carrier for smooth and uniform operation.展开更多
Near-fault strong ground motion of strike-slip and dip-slip of vertical and inclined rectangular fault in half-space and layered half-space is analyzed by dislocation source model. The Fourier spectra ratio of ground ...Near-fault strong ground motion of strike-slip and dip-slip of vertical and inclined rectangular fault in half-space and layered half-space is analyzed by dislocation source model. The Fourier spectra ratio of ground motion is adopted to study the characteristics of near-fault ground motion. For both slip models, near-fault strong ground motion with high amplitude is located in a narrow belt area along the projection of the fault on the ground and mainly controlled by the sub-faults nearby. Directivity of strike-slip fault is more dominant in long period for components perpendicular to the fault, and more dominant in long period for components parallel to the fault for dip-slip fault. The deeper the location of the source is, the more slowly the amplitude of ground motion attenuates. There is obvious hanging wall effect in ground motion of inclined fault, and the spatial distribution of ground motion is asymmetric which coincides with observational data. Finally, a fitting function of spatial distribution for near-fault ground motion is proposed and compared with near source factors of the 1997 Uniform Building Code of USA.展开更多
Physical model tests have been conducted by various researchers to investigate fault rupture propagation and ground deformation induced by bedrock faulting. However, the effects of pre-existing fracture on ground defo...Physical model tests have been conducted by various researchers to investigate fault rupture propagation and ground deformation induced by bedrock faulting. However, the effects of pre-existing fracture on ground deformation are not fully understood. In this work, six centrifuge tests are reported to investigate the influence of pre-existing fracture on ground deformation induced by normal faulting in sand, clay and nine-layered soil with interbedded sand and clay layers. Shear box tests were conducted to develop a filter paper technique, which was adopted in soil model preparation to simulate the effects of pre-existing fracture in centrifuge tests. Centrifuge test results show that ground deformation mechanism in clay, sand and nine-layered soil strata is classified as a stationary zone, a shearing zone and a rigid body zone. Inclination of the strain localization is governed by the dilatancy of soil material. Moreover, the pre-existing fracture provides a preferential path for ground deformation and results in a scarp at the ground surface in sand. On the contrary, fault ruptures are observed at the ground surface in clay and nine-layered soil strata.展开更多
In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line select...In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line selection always existed in existing methods. According to the characteristics that transient current was different between the fault feeder and other faultless feeders, wavelet transformation was performed on data of the transient current within a power frequency cycle after the fault occurred. Based on different fault angles, wavelet energy in corresponding frequency band was chosen to compare. The result was that wavelet energy in fault feeder was the largest of all, and it was larger than sum of those in other faultless feeders, when the bus broke down, the disparity between each wavelet energy was not significant. Fault line could be selected out by the criterion above. The results of MATLAB/simulink simulation experiment indicated that this method had anti-interference capacity and was feasible.展开更多
零序电流互感器(current transformer,CT)测量精度问题一直是限制配电网故障选线准确率的关键性问题,现有研究方法在理论层面已较为成熟,但在现场使用中受限于零序CT测量精度,耐过渡电阻能力往往不佳。灵活接地系统是一种新型接地方式,...零序电流互感器(current transformer,CT)测量精度问题一直是限制配电网故障选线准确率的关键性问题,现有研究方法在理论层面已较为成熟,但在现场使用中受限于零序CT测量精度,耐过渡电阻能力往往不佳。灵活接地系统是一种新型接地方式,系统感知永久性接地故障后,于中性点投入并联小电阻,使得配电网接地方式发生转变,从而导致同一电气信号量呈现两种完全不同的故障特征,故障信息量增加了一倍,综合利用两阶段故障特征有望突破现有故障选线装置性能极限,摆脱选线装置对零序CT测量精度的依赖。为此,该文首先分析了灵活接地系统不同阶段各电气量的故障特征,之后结合灵活接地系统特点提出了一种基于零序电流幅值比的高阻接地故障选线方法,最后通过合理设计选线算法,剔除误差较大数据,最大程度降低保护对零序CT测量精度的依赖。实时数字仿真系统(real time digital simulation system,RTDS)以及低压实验平台实验结果表明,该方法不受零序CT极性反接与相位测量误差影响,且无需故障信息间的横向比较,具有耐过渡电阻能力强、可靠性高、对零序CT测量精度要求低、易实现等优点。展开更多
基金supported by the Shanxi Provincial Natural Science Basic Research Program Young Talent Project(S2019-JC-QN-2408).
文摘The process of ground vehicle dynamic gravimetry is inevitably affected by the carrier’s maneuvering acceleration,which makes the result contain a large amount of dynamic error.In this paper,we propose a dynamic error suppression method of gravimetry based on the high-precision acquisition of external velocity for compensating the horizontal error of the inertial plat-form.On the basis of platform gravity measurement,firstly,the dynamic performance of the system is enhanced by optimizing the horizontal damping network of the inertial platform and selecting its parameter.Secondly,an improved federal Kalman filtering algorithm and a fault diagnosis method are designed using strapdown inertial navigation system(SINS),odometer(OD),and laser Doppler velocimeter(LDV).Simulation validates that these methods can improve the accuracy and robustness of the external velocity acquisition.Three survey lines are selected in Tianjin,China,for the gravimetry experiments with different maneuvering levels,and the results demonstrate that after dynamic error suppression,the internal coincidence accuracies of smooth and uniform operation,obvious acceleration and deceleration operation,and high-dynamic operation are improved by 70.2%,73.6%,and 77.9%to reach 0.81 mGal,1.30 mGal,and 1.94 mGal,respectively,and the external coinci-dence accuracies during smooth and uniform operation are improved by 48.6%up to 1.66 mGal.It is shown that the pro-posed method can effectively suppress the dynamic error,and that the accuracy improvement increases with carrier maneuver-ability.However,the amount of residual error that can not be entirely eliminated increases as well,so the ground vehicle dynamic gravimetry should be maintained in the carrier for smooth and uniform operation.
基金National Natural Science Foundation of China (59895410) Commonweal Foundation of the Ministry of Science and Technology of China (2001DIB20098).
文摘Near-fault strong ground motion of strike-slip and dip-slip of vertical and inclined rectangular fault in half-space and layered half-space is analyzed by dislocation source model. The Fourier spectra ratio of ground motion is adopted to study the characteristics of near-fault ground motion. For both slip models, near-fault strong ground motion with high amplitude is located in a narrow belt area along the projection of the fault on the ground and mainly controlled by the sub-faults nearby. Directivity of strike-slip fault is more dominant in long period for components perpendicular to the fault, and more dominant in long period for components parallel to the fault for dip-slip fault. The deeper the location of the source is, the more slowly the amplitude of ground motion attenuates. There is obvious hanging wall effect in ground motion of inclined fault, and the spatial distribution of ground motion is asymmetric which coincides with observational data. Finally, a fitting function of spatial distribution for near-fault ground motion is proposed and compared with near source factors of the 1997 Uniform Building Code of USA.
基金Project supported by the Earthquake Administration of Beijing Municipality and the National Development and Reform Commission of ChinaProject(IRT1125) supported by the program for Changjiang Scholars and Innovative Research Team in University, China
文摘Physical model tests have been conducted by various researchers to investigate fault rupture propagation and ground deformation induced by bedrock faulting. However, the effects of pre-existing fracture on ground deformation are not fully understood. In this work, six centrifuge tests are reported to investigate the influence of pre-existing fracture on ground deformation induced by normal faulting in sand, clay and nine-layered soil with interbedded sand and clay layers. Shear box tests were conducted to develop a filter paper technique, which was adopted in soil model preparation to simulate the effects of pre-existing fracture in centrifuge tests. Centrifuge test results show that ground deformation mechanism in clay, sand and nine-layered soil strata is classified as a stationary zone, a shearing zone and a rigid body zone. Inclination of the strain localization is governed by the dilatancy of soil material. Moreover, the pre-existing fracture provides a preferential path for ground deformation and results in a scarp at the ground surface in sand. On the contrary, fault ruptures are observed at the ground surface in clay and nine-layered soil strata.
文摘In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line selection always existed in existing methods. According to the characteristics that transient current was different between the fault feeder and other faultless feeders, wavelet transformation was performed on data of the transient current within a power frequency cycle after the fault occurred. Based on different fault angles, wavelet energy in corresponding frequency band was chosen to compare. The result was that wavelet energy in fault feeder was the largest of all, and it was larger than sum of those in other faultless feeders, when the bus broke down, the disparity between each wavelet energy was not significant. Fault line could be selected out by the criterion above. The results of MATLAB/simulink simulation experiment indicated that this method had anti-interference capacity and was feasible.
文摘零序电流互感器(current transformer,CT)测量精度问题一直是限制配电网故障选线准确率的关键性问题,现有研究方法在理论层面已较为成熟,但在现场使用中受限于零序CT测量精度,耐过渡电阻能力往往不佳。灵活接地系统是一种新型接地方式,系统感知永久性接地故障后,于中性点投入并联小电阻,使得配电网接地方式发生转变,从而导致同一电气信号量呈现两种完全不同的故障特征,故障信息量增加了一倍,综合利用两阶段故障特征有望突破现有故障选线装置性能极限,摆脱选线装置对零序CT测量精度的依赖。为此,该文首先分析了灵活接地系统不同阶段各电气量的故障特征,之后结合灵活接地系统特点提出了一种基于零序电流幅值比的高阻接地故障选线方法,最后通过合理设计选线算法,剔除误差较大数据,最大程度降低保护对零序CT测量精度的依赖。实时数字仿真系统(real time digital simulation system,RTDS)以及低压实验平台实验结果表明,该方法不受零序CT极性反接与相位测量误差影响,且无需故障信息间的横向比较,具有耐过渡电阻能力强、可靠性高、对零序CT测量精度要求低、易实现等优点。