---Double data rate synchronous dynamic random access memory (DDR3) has become one of the most mainstream applications in current server and computer systems. In order to quickly set up a system-level signal integri...---Double data rate synchronous dynamic random access memory (DDR3) has become one of the most mainstream applications in current server and computer systems. In order to quickly set up a system-level signal integrity (SI) simulation flow for the DDR3 interface, two system-level SI simulation methodologies, which are board-level S-parameter extraction in the frequency-domain and system-level simulation assumptions in the time domain, are introduced in this paper. By comparing the flow of Speed2000 and PowerSI/Hspice, PowerSI is chosen for the printed circuit board (PCB) board-level S-parameter extraction, while Tektronix oscilloscope (TDS7404) is used for the DDR3 waveform measurement. The lab measurement shows good agreement between simulation and measurement. The study shows that the combination of PowerSI and Hspice is recommended for quick system-level DDR3 SI simulation.展开更多
A simulation method to simulate the pseudorandom code P. M PP radar' s echo signal is proposed that makes use of the pre-generated Doppler simulation data, according to the relative movement parameter of the radar an...A simulation method to simulate the pseudorandom code P. M PP radar' s echo signal is proposed that makes use of the pre-generated Doppler simulation data, according to the relative movement parameter of the radar and the target. It resolves the problem of the high precision distance simulation and the high speed digital shift phase. At the same time, the radar dynamic digital video frequency target signal simulator is designed. Simulation results of the critical unit and the output waveform are given. The result of the test satisfies the system's request.展开更多
We develop an improved design of thin gap chamber (TGC) simulation signal source. To further simulate the feature of TGC detector, a novel thought is proposed. The TGC source has 256 channels. Every channel can rand...We develop an improved design of thin gap chamber (TGC) simulation signal source. To further simulate the feature of TGC detector, a novel thought is proposed. The TGC source has 256 channels. Every channel can randomly output the signal in 25 ns. The design is based on true random number generator (TRNG). Considering the electrical connection between the TGC source and the developing trigger electronics, the GFZ connector is used. The experimental results show that the improved TGC simulation signal source can uniformly output the random signal in every channel. The output noise is less than 3 mVrms.展开更多
The neutron flux monitor(NFM)system is an important diagnostic subsystem introduced by large nuclear fusion devices such as international thermonuclear experimental reactor(ITER),Japan torus-60,tokamak fusion test rea...The neutron flux monitor(NFM)system is an important diagnostic subsystem introduced by large nuclear fusion devices such as international thermonuclear experimental reactor(ITER),Japan torus-60,tokamak fusion test reactor,and HL-2 A.Neutron fluxes can provide real-time parameters for nuclear fusion,including neutron source intensity and fusion power.Corresponding to different nuclear reaction periods,neutron fluxes span over seven decades,thereby requiring electronic devices to operate in counting and Campbelling modes simultaneously.Therefore,it is crucial to design a real-time NFM system to encompass such a wide dynamic range.In this study,a high-precision NFM system with a wide measurement range of neutron flux is implemented using realtime multipoint linear calibration.It can automatically switch between counting and Campbelling modes with variations in the neutron flux.We established a testing platform to verify the feasibility of the NFM system,which can output the simulated neutron signal using an arbitrary waveform generator.Meanwhile,the accurate calibration interval of the Campbelling mode is defined well.Based on the above-mentioned design,the system satisfies the requirements,offering a dynamic range of 10~8 cps,temporal resolution of 1 ms,and maximal relative error of 4%measured at the signal-to-noise ratio of 15.8 dB.Additionally,the NFM system is verified in a field experiment involving HL-2 A,and the measured neutron flux is consistent with the results.展开更多
基金supported by the National Natural Science Foundation of China under Grant No.61161001
文摘---Double data rate synchronous dynamic random access memory (DDR3) has become one of the most mainstream applications in current server and computer systems. In order to quickly set up a system-level signal integrity (SI) simulation flow for the DDR3 interface, two system-level SI simulation methodologies, which are board-level S-parameter extraction in the frequency-domain and system-level simulation assumptions in the time domain, are introduced in this paper. By comparing the flow of Speed2000 and PowerSI/Hspice, PowerSI is chosen for the printed circuit board (PCB) board-level S-parameter extraction, while Tektronix oscilloscope (TDS7404) is used for the DDR3 waveform measurement. The lab measurement shows good agreement between simulation and measurement. The study shows that the combination of PowerSI and Hspice is recommended for quick system-level DDR3 SI simulation.
文摘A simulation method to simulate the pseudorandom code P. M PP radar' s echo signal is proposed that makes use of the pre-generated Doppler simulation data, according to the relative movement parameter of the radar and the target. It resolves the problem of the high precision distance simulation and the high speed digital shift phase. At the same time, the radar dynamic digital video frequency target signal simulator is designed. Simulation results of the critical unit and the output waveform are given. The result of the test satisfies the system's request.
基金Supported by the State Key Laboratory of Particle Detection and Electronicsthe National Natural Science Foundation of China under Grant No 11375179
文摘We develop an improved design of thin gap chamber (TGC) simulation signal source. To further simulate the feature of TGC detector, a novel thought is proposed. The TGC source has 256 channels. Every channel can randomly output the signal in 25 ns. The design is based on true random number generator (TRNG). Considering the electrical connection between the TGC source and the developing trigger electronics, the GFZ connector is used. The experimental results show that the improved TGC simulation signal source can uniformly output the random signal in every channel. The output noise is less than 3 mVrms.
基金supported by the National Natural Science Foundation of China(Nos.11475131,11975307,and 11575184)the National Magnetic Confinement Fusion Energy Development Research(No.2013GB104003)。
文摘The neutron flux monitor(NFM)system is an important diagnostic subsystem introduced by large nuclear fusion devices such as international thermonuclear experimental reactor(ITER),Japan torus-60,tokamak fusion test reactor,and HL-2 A.Neutron fluxes can provide real-time parameters for nuclear fusion,including neutron source intensity and fusion power.Corresponding to different nuclear reaction periods,neutron fluxes span over seven decades,thereby requiring electronic devices to operate in counting and Campbelling modes simultaneously.Therefore,it is crucial to design a real-time NFM system to encompass such a wide dynamic range.In this study,a high-precision NFM system with a wide measurement range of neutron flux is implemented using realtime multipoint linear calibration.It can automatically switch between counting and Campbelling modes with variations in the neutron flux.We established a testing platform to verify the feasibility of the NFM system,which can output the simulated neutron signal using an arbitrary waveform generator.Meanwhile,the accurate calibration interval of the Campbelling mode is defined well.Based on the above-mentioned design,the system satisfies the requirements,offering a dynamic range of 10~8 cps,temporal resolution of 1 ms,and maximal relative error of 4%measured at the signal-to-noise ratio of 15.8 dB.Additionally,the NFM system is verified in a field experiment involving HL-2 A,and the measured neutron flux is consistent with the results.