To estimate the direction-of-arrival (DOA) of wideband coherent signals, a new method by modifying the orthogonality of the projected suhspaces method is proposed. And it can deal with randomly position perturbed ar...To estimate the direction-of-arrival (DOA) of wideband coherent signals, a new method by modifying the orthogonality of the projected suhspaces method is proposed. And it can deal with randomly position perturbed arrays by using the Toeplitz method. This method needn't the primary information of DOA for focusing matrix and the sector dividing of interpolated method, which improving the precision of estimation and reducing the computational complexity. Simulations illustrate the effectiveness of this method.展开更多
The approach of estimating the number of signals based on information theoretic criteria has good performance in the assumption of white noise, but it always leads to false estimation of the coherent sources in colore...The approach of estimating the number of signals based on information theoretic criteria has good performance in the assumption of white noise, but it always leads to false estimation of the coherent sources in colored noise. An approach combining the combined information theoretic criteria and eigen- value correction, is presented to determine number of signals. The method uses maximum likelihood (ML) and information theoretic criteria to estimate coherent signals alternately, then eliminate the inequality of the eigenvalues caused by colored noise by correcting the noise eigenvalues. The computer simulation results prove the effective performance of the method.展开更多
Vehicle positioning with the global navigation satellite system (GNSS) in urban environments faces two problems which are attenuation and dynamic. For traditional GNSS receivers hardly able to track dynamic weak sig...Vehicle positioning with the global navigation satellite system (GNSS) in urban environments faces two problems which are attenuation and dynamic. For traditional GNSS receivers hardly able to track dynamic weak signals, the coupling between all visible satellite signals is ignored in the absence of navigation state feedback, and thermal noise error and dynamic stress threshold are contradictory due to non-coherent discriminators. The vector delay/frequency locked loop (VDFLL) with navigation state feedback and the joint vector tracking loop (JVTL) with coherent discriminator which is a synchronization parameter tracking loop based on maximum likelihood estimation (MLE) are proposed to improve the tracking sensitivity of GNSS receiver in dynamic weak signal environments. A joint vector position tracking loop (JVPTL) directly tracking user position and velocity is proposed to further improve tracking sensitivity. The coherent navigation parameter discriminator of JVPTL, being able to ease the contradiction between thermal noise error and dynamic stress threshold, is based on MLE according to the navigation parameter based linear model of received baseband signals. Simulation results show that JVPTL, which combines the advantages of both VDFLL and JVTL, performs better than both VDFLL and JVTL in dynamic weak signal environments.展开更多
The problem of adaptive detection in the situation of signal mismatch is considered; that is, the actual signal steering vector is not aligned with the nominal one. Two novel tunable detectors are proposed. They can c...The problem of adaptive detection in the situation of signal mismatch is considered; that is, the actual signal steering vector is not aligned with the nominal one. Two novel tunable detectors are proposed. They can control the degree to which the mismatched signals are rejected. Remarkably, it is found that they both cover existing famous detectors as their special cases. More importantly, they possess the constant false alarm rate(CFAR)property and achieve enhanced mismatched signal rejection or improved robustness than their natural competitors. Besides, they can provide slightly better matched signals detection performance than the existing detectors.展开更多
Ubiquitous radar is a new radar system that provides continuous and uninterrupted multifunction capability within a coverage volume. Continuous coverage from close-in "pop-up" targets in clutter to long-range target...Ubiquitous radar is a new radar system that provides continuous and uninterrupted multifunction capability within a coverage volume. Continuous coverage from close-in "pop-up" targets in clutter to long-range targets impacts selection of waveform parameters. The coherent processing interval (CPI) must be long enough to achieve a certain signal-to-noise ratio (SNR) that ensures the efficiency of detection. The condition of detection in the case of low SNR is analyzed, and three different cases that would occur during integration are discussed and a method to determine the CPI is presented. The simulation results show that targets detection with SNR as low as -26 dB in the experimental system can possibly determine the CPI.展开更多
Perlecan,a heparan sulfate proteoglycan,acts as a mechanical sensor for bone to detect external loading.Deficiency of perlecan increases the risk of osteoporosis in patients with Schwartz-Jampel Syndrome(SJS)and atten...Perlecan,a heparan sulfate proteoglycan,acts as a mechanical sensor for bone to detect external loading.Deficiency of perlecan increases the risk of osteoporosis in patients with Schwartz-Jampel Syndrome(SJS)and attenuates loading4nduced bone formation in perlecan deficient mice(Hypo).Considering that intracellular calcium[Ca2+]i is an ubiquitous messenger controlling numerous cellular processes including mechanotransduction,we hypothesized that perlecan deficiency impairs bone’s calcium signaling in response to loading.To test this,we performed real-time[Ca2+]i imaging on in situ osteocytes of adult murine tibiae under cyclic loading(8 N,Figure 1).Relative to wild type(WT),Hypo osteocytes showed decreases in the overall[Ca2+]i response rate(-58%),calcium peaks(-33%),cells with multiple peaks(-53%),peak magnitude(-6.8%),and recovery speed to baseline(-23%).RNA sequencing and pathway analysis of tibiae from mice subjected to one or seven days of unilateral loading demonstrated that perlecan deficiency significantly suppressed the calcium signaling,ECM-receptor interaction,and focal adhesion pathways following repetitive loading.Defects in the endoplasmic reticulum(ER)calcium cycling regulators such as Ryr1/ryanodine receptors and Atp2a1/Sercal calcium pumps were identified in Hypo bones.Taken together,impaired calcium signaling may contribute to bone’s reduced anabolic response to loading,underlying the osteoporosis risk for the SJS patients.展开更多
文摘To estimate the direction-of-arrival (DOA) of wideband coherent signals, a new method by modifying the orthogonality of the projected suhspaces method is proposed. And it can deal with randomly position perturbed arrays by using the Toeplitz method. This method needn't the primary information of DOA for focusing matrix and the sector dividing of interpolated method, which improving the precision of estimation and reducing the computational complexity. Simulations illustrate the effectiveness of this method.
文摘The approach of estimating the number of signals based on information theoretic criteria has good performance in the assumption of white noise, but it always leads to false estimation of the coherent sources in colored noise. An approach combining the combined information theoretic criteria and eigen- value correction, is presented to determine number of signals. The method uses maximum likelihood (ML) and information theoretic criteria to estimate coherent signals alternately, then eliminate the inequality of the eigenvalues caused by colored noise by correcting the noise eigenvalues. The computer simulation results prove the effective performance of the method.
基金supported by the National Natural Science Foundation for Young Scientists of China(61201190)
文摘Vehicle positioning with the global navigation satellite system (GNSS) in urban environments faces two problems which are attenuation and dynamic. For traditional GNSS receivers hardly able to track dynamic weak signals, the coupling between all visible satellite signals is ignored in the absence of navigation state feedback, and thermal noise error and dynamic stress threshold are contradictory due to non-coherent discriminators. The vector delay/frequency locked loop (VDFLL) with navigation state feedback and the joint vector tracking loop (JVTL) with coherent discriminator which is a synchronization parameter tracking loop based on maximum likelihood estimation (MLE) are proposed to improve the tracking sensitivity of GNSS receiver in dynamic weak signal environments. A joint vector position tracking loop (JVPTL) directly tracking user position and velocity is proposed to further improve tracking sensitivity. The coherent navigation parameter discriminator of JVPTL, being able to ease the contradiction between thermal noise error and dynamic stress threshold, is based on MLE according to the navigation parameter based linear model of received baseband signals. Simulation results show that JVPTL, which combines the advantages of both VDFLL and JVTL, performs better than both VDFLL and JVTL in dynamic weak signal environments.
基金supported by the National Natural Science Foundation of China(6110216960925005)
文摘The problem of adaptive detection in the situation of signal mismatch is considered; that is, the actual signal steering vector is not aligned with the nominal one. Two novel tunable detectors are proposed. They can control the degree to which the mismatched signals are rejected. Remarkably, it is found that they both cover existing famous detectors as their special cases. More importantly, they possess the constant false alarm rate(CFAR)property and achieve enhanced mismatched signal rejection or improved robustness than their natural competitors. Besides, they can provide slightly better matched signals detection performance than the existing detectors.
文摘Ubiquitous radar is a new radar system that provides continuous and uninterrupted multifunction capability within a coverage volume. Continuous coverage from close-in "pop-up" targets in clutter to long-range targets impacts selection of waveform parameters. The coherent processing interval (CPI) must be long enough to achieve a certain signal-to-noise ratio (SNR) that ensures the efficiency of detection. The condition of detection in the case of low SNR is analyzed, and three different cases that would occur during integration are discussed and a method to determine the CPI is presented. The simulation results show that targets detection with SNR as low as -26 dB in the experimental system can possibly determine the CPI.
基金supported by NIH grants ( P30GM103333,R01AR054385)supported partially by a core access award through NIH NIGMS IDeA Program grant ( P20GM103446)
文摘Perlecan,a heparan sulfate proteoglycan,acts as a mechanical sensor for bone to detect external loading.Deficiency of perlecan increases the risk of osteoporosis in patients with Schwartz-Jampel Syndrome(SJS)and attenuates loading4nduced bone formation in perlecan deficient mice(Hypo).Considering that intracellular calcium[Ca2+]i is an ubiquitous messenger controlling numerous cellular processes including mechanotransduction,we hypothesized that perlecan deficiency impairs bone’s calcium signaling in response to loading.To test this,we performed real-time[Ca2+]i imaging on in situ osteocytes of adult murine tibiae under cyclic loading(8 N,Figure 1).Relative to wild type(WT),Hypo osteocytes showed decreases in the overall[Ca2+]i response rate(-58%),calcium peaks(-33%),cells with multiple peaks(-53%),peak magnitude(-6.8%),and recovery speed to baseline(-23%).RNA sequencing and pathway analysis of tibiae from mice subjected to one or seven days of unilateral loading demonstrated that perlecan deficiency significantly suppressed the calcium signaling,ECM-receptor interaction,and focal adhesion pathways following repetitive loading.Defects in the endoplasmic reticulum(ER)calcium cycling regulators such as Ryr1/ryanodine receptors and Atp2a1/Sercal calcium pumps were identified in Hypo bones.Taken together,impaired calcium signaling may contribute to bone’s reduced anabolic response to loading,underlying the osteoporosis risk for the SJS patients.