With the rapid increase of wind farms,the grid code needs to be improved to meet the requirement of wind farms and enhance grid stability.Doubly-fed induction generators are largely used in wind turbines,but they are ...With the rapid increase of wind farms,the grid code needs to be improved to meet the requirement of wind farms and enhance grid stability.Doubly-fed induction generators are largely used in wind turbines,but they are very sensitive to grid disturbances.The voltage swell can be caused by switching on capacitor banks or switching off large loads,which may result in the reversal of the power flow in the grid convertor;the current may flow from the grid into the DC link,which may step up DC voltage,and result in large faults of rotor currents and instantaneous power oscillation.The grid reactive compensation devices can not have the automatic swithing function after the low voltage fault,which will result in local reactive power surplus,so some wind power generators will retreat from the grid under high voltage protection.展开更多
In order to evaluate a full trailer’s vibration performance,lumped mass model of seven degrees of freedom is set up to predict the ride comfort of whole vehicle.The acceleration history and the transfer function of e...In order to evaluate a full trailer’s vibration performance,lumped mass model of seven degrees of freedom is set up to predict the ride comfort of whole vehicle.The acceleration history and the transfer function of each measuring point can be got from simulation.The analysis results show that the maximum acceleration RMS value of the vehicle mass center is about 0.3g,which satisfies the requirements of attenuating vibration of precision equipment being transported on particular roads and speeds.So the research provides valuable reference for the optimum selection of the suspension system’s parameters.展开更多
文摘With the rapid increase of wind farms,the grid code needs to be improved to meet the requirement of wind farms and enhance grid stability.Doubly-fed induction generators are largely used in wind turbines,but they are very sensitive to grid disturbances.The voltage swell can be caused by switching on capacitor banks or switching off large loads,which may result in the reversal of the power flow in the grid convertor;the current may flow from the grid into the DC link,which may step up DC voltage,and result in large faults of rotor currents and instantaneous power oscillation.The grid reactive compensation devices can not have the automatic swithing function after the low voltage fault,which will result in local reactive power surplus,so some wind power generators will retreat from the grid under high voltage protection.
基金Supported by Program of Natural and Science Funds of Shandong Province(ZR2009FL014)the Program of Natural and Science Funds of Shandong Jiaotong University(Z201228)
文摘In order to evaluate a full trailer’s vibration performance,lumped mass model of seven degrees of freedom is set up to predict the ride comfort of whole vehicle.The acceleration history and the transfer function of each measuring point can be got from simulation.The analysis results show that the maximum acceleration RMS value of the vehicle mass center is about 0.3g,which satisfies the requirements of attenuating vibration of precision equipment being transported on particular roads and speeds.So the research provides valuable reference for the optimum selection of the suspension system’s parameters.