Objective To qualitatively assess the diagnostic performance of dynamic contrast enhancement(DCE),diffusionweighted imaging(DWI),and T2-weighted imaging(T2WI),alone or in combination,in the evaluation of breast cancer...Objective To qualitatively assess the diagnostic performance of dynamic contrast enhancement(DCE),diffusionweighted imaging(DWI),and T2-weighted imaging(T2WI),alone or in combination,in the evaluation of breast cancer.Methods We retrospectively reviewed the records of 394 consecutive patients with pathologically confirmed breast lesions who had undergone 3-T magnetic resonance imaging(MRI).The morphological characteristics of breast lesions were evaluated using DCE,DWI,and T2WI based on BI-RADS lexicon descriptors by trained radiologists.Patients were categorized into mass and non-mass groups based on MRI characteristics of the lesions,and the differences between benign and malignant lesions in each group were compared.Clinical prediction models for breast cancer diagnosis were constructed using logistic regression analysis.Diagnostic efficacies were compared using the area under the receiver operating characteristic curve(AUC)and DeLong test.Results For mass-like lesions,all the morphological parameters significantly differentiated benign and malignant lesions on consensus DCE,DWI,and T2WI(P<0.05).The combined method(DCE+DWI+T2WI)had a higher AUC(0.865)than any of the individual modality(DCE:0.786;DWI:0.793;T2WI:0.809)(P<0.05).For non-mass-like lesions,DWI signal intensity was a significant predictor of malignancy(P=0.036),but the model using DWI alone had a low AUC(0.669).Conclusion Morphological assessment using the combination of DCE,DWI,and T2WI provides better diagnostic value in differentiating benign and malignant breast mass-like lesions than assessment with only one of the modalities.展开更多
Objective To explore the correlations of transcranial sonography of substantia nigra(SN-TCS)characteristics with MRI iron deposition on substantia nigra in patients with Parkinson disease(PD).Methods Data of SN-TCS an...Objective To explore the correlations of transcranial sonography of substantia nigra(SN-TCS)characteristics with MRI iron deposition on substantia nigra in patients with Parkinson disease(PD).Methods Data of SN-TCS and craniocerebral MRI in 120 PD patients were retrospectively analyzed.The patients were divided into iron deposition positive group(positive group,n=46)and iron deposition negative group(negative group,n=74)according to quantitative susceptibility mapping(QSM)value.Then parameters of SN-TCS and MRI were compared between groups(both P<0.05),and correlation analysis were also performed.Results The proportion of high echo positive,strong echo area and QSM value of substantia nigra,as well as of hyper-substantia nigra area/midbrain area(S/M)in positive group were all higher than those in negative group(all P<0.001).No significant difference of midbrain area was found between groups(P>0.05).Strong echo area of substantia nigra and S/M based on SN-TCS were both low-medium positively correlated with substantia nigra QSM value showed on MRI(r=0.497,0.529,both P<0.001).Conclusion SN-TCS characteristics of PD patients were correlated with MRI iron deposition on substantia nigra,among which strong echo area and S/M were valuable for evaluating iron deposition on substantia nigra.展开更多
Alzheimer's disease(AD)is a prevalent neurodegenerative disease characterized by cognitive decline in the early stage.Mild cognitive impairment(MCI)is considered as an intermediate stage between normal aging and A...Alzheimer's disease(AD)is a prevalent neurodegenerative disease characterized by cognitive decline in the early stage.Mild cognitive impairment(MCI)is considered as an intermediate stage between normal aging and AD.In recent years,studies related to resting-state functional MRI(rs-fMRI)indicated that the occurrence and development process of MCI and AD might be closely linked to spontaneous brain activity and alterations in functional connectivity among brain regions,and rs-fMRI could provide important reference for specific diagnosis and early treatment of MCI and AD.The research progresses of rs-fMRI for MCI and AD were reviewed in this article.展开更多
Objective To observe the clinical application value of total free-breathing cardiac MR(CMR)examination preliminarily.Methods Two patients who underwent CMR scanning under free-breathing state,including cine,motion cor...Objective To observe the clinical application value of total free-breathing cardiac MR(CMR)examination preliminarily.Methods Two patients who underwent CMR scanning under free-breathing state,including cine,motion correction T1 and T2 mapping,blood flow imaging,and late gadolinium enhancement scanning were retrospectively enrolled,and the qualities of the above images were evaluated and compared with that of conventional CMR images under breath-holding state.Results No significant difference of imaging quality was found between total free-breathing and conventional breath-holding CMR.The differences of left ventricular ejection fraction,cardiac output,left ventricular end-diastolic volume index and left ventricular mass measured based on CMR images under different breath conditions were limited.Conclusion Total free-breathing CMR was feasible in clinical practice,which could provide"one-stop"evaluation of cardiac structure,function and myocardial histological characteristics,hence having promising clinical prospects.展开更多
Objective To observe the value of isotropic volumetric MRI for displaying perineural spread(PNS)of cranial nerve(CN)in nasopharyngeal carcinoma.Methods Eighty-seven patients with pathologically proven nasopharyngeal c...Objective To observe the value of isotropic volumetric MRI for displaying perineural spread(PNS)of cranial nerve(CN)in nasopharyngeal carcinoma.Methods Eighty-seven patients with pathologically proven nasopharyngeal carcinoma were prospectively enrolled.MR scanning,including three-dimensional liver acquisition with volume acceleration-flexible(3D LAVA_Flex)image,T2WI with fat suppression(T2WI-FS),T1WI,contrast enhancement(CE)T1WI-FS of nasopharynx and neck region were performed.The displaying rates of CN PNS were evaluated and compared between 3D LAVA_Flex and T2WI-FS,T1WI,CE-T1WI-FS at patient level,CN group level and neural level,respectively.Results The displaying rate of CN PNS in all 87 nasopharyngeal carcinoma patients by 3D LAVA_Flex sequence was 49.43%(43/87),higher than that of conventional MRI(30/87,34.48%,P=0.001).Among 59 patients with advanced nasopharyngeal carcinoma diagnosed with conventional sequences,the displaying rate of CN PNS was 71.19%(42/59)by 3D LAVA-Flex sequence,higher than that of conventional MRI(30/59,50.85%,P=0.001).At both patient level and posterior CN level,significant differences of the displaying rate of CN PNS were found between 3D LAVA-Flex sequence and T2WI-FS,T1WI,CE-T1WI-FS,while at CN level,the displaying rates of mandibular nerve PNS,CNⅨ—ⅪPNS in jugular foramen(P<0.05)and CNⅨ—ⅫPNS in carotid space of 3D LAVA_Flex sequence were all significantly higher than that of T2WI-FS,T1WI and CE-T1WI-FS(all P<0.05),of PNS of CNⅢ—Ⅴin cavernous sinus were higher than that of T2WI-FS(P<0.05),while of PNS of hypoglossal nerve were significantly higher than that of T2WI-FS and T1WI(both P<0.05).Conclusion 3D LAVA_Flex sequence could be used to effectively display CN PNS of nasopharyngeal carcinoma.展开更多
Objective To observe the value of intravoxel incoherent motion(IVIM)and dynamic contrast-enhanced MRI(DCE-MRI)for assessing abnormalities of brucellosis spondylitis(BS)without conventional MRI changes.Methods Data of ...Objective To observe the value of intravoxel incoherent motion(IVIM)and dynamic contrast-enhanced MRI(DCE-MRI)for assessing abnormalities of brucellosis spondylitis(BS)without conventional MRI changes.Methods Data of 36 brucellosis patients with definite spinal lesions displayed on conventional MRI(BS 1 group),14 cases without brucellosis infection nor abnormal spinal signals on MRI(control group)and 36 brucellosis patients without definite spinal lesions on conventional MRI(BS 2 group)were retrospectively analyzed.The values of IVIM parameters,including perfusion fraction(f),pure water diffusion coefficient(D)and pseudo-diffusion coefficient(D*),also of DCE-MRI parameters,including time-intensity curve(TIC)type,volume transport constant(K trans),the rate constant(K ep)and volume fraction of extravascular extracellular space per unit tissue volume(V e)were compared among groups.Univariate and multivariate logistic regression were used to screen independent factors for discriminating BS 1 and BS 2.Receiver operating characteristic curves were drawn,and the areas under the curve(AUC)were calculated to evaluate the efficiency of the above parameters for discriminating BS 1 and BS 2.Results Among IVIM parameters,compared with control group,D*values decreased but D values increased in BS 1 group,while D*values increased in BS 2 group(all adjusted P<0.05).Compared with BS 2 group,BS 1 group had higher values of f and D and lower D*(all adjusted P<0.05).In BS 1 group,the TIC types were predominantly typeⅠ(23/36,63.89%),which were wholly or predominantly typeⅢin BS 2 group and control group,and of the former was significantly different with latter 2(both adjusted P<0.05).Compared with control group,K trans increased progressively in both BS 1 and BS 2 groups(both adjusted P<0.05).BS 1 group had lower K ep and higher V e than BS 2 and control groups(all adjusted P<0.05).Among univariate logistic regression models,the model including only f had lower capability for discriminating BS 1 and BS 2(AUC=0.759)than those including D,K trans and V e(AUC=0.951,0.833,0.894,all P<0.05).No significant different was found among multivariate logistic regression model including f and D,model including K trans and V e nor model including all above parameters(all P>0.05).Conclusion Both IVIM and DCE-MRI could be used to evaluate BS abnormality without conventional MRI changes.展开更多
The incidence of lumbar degenerative diseases is increasing year by year,and MRI is often used in clinical diagnosis.In recent years,artificial intelligence(AI)has rapidly developed in medical field and can be used fo...The incidence of lumbar degenerative diseases is increasing year by year,and MRI is often used in clinical diagnosis.In recent years,artificial intelligence(AI)has rapidly developed in medical field and can be used for image segmentation and auxiliary diagnosis of lumbar degenerative diseases.The research progresses of AI in MRI of lumbar degenerative diseases were reviewed in this article.展开更多
Objective To observe the value of grey-level histogram analysis based on T2WI for differentiating consistency of meningioma.Methods Data of 109 patients with meningioma were retrospectively analyzed.The patients were ...Objective To observe the value of grey-level histogram analysis based on T2WI for differentiating consistency of meningioma.Methods Data of 109 patients with meningioma were retrospectively analyzed.The patients were divided into hard group(n=71)and soft group(n=38)according to the consistency of tumors.Tumor ROI was outlined on axial T2WI showing the largest tumor section,gray levels were extracted and histogram analysis was performed.The value of each histogram parameter were compared between groups.Then receiver operating characteristic curve was drawn,and the area under the curve(AUC)was calculated to evaluate the efficiency for differentiating soft and hard meningioma.Results P 1,P 10,P 50,P 90,P 99 and the mean grey levels on T2WI in soft group were all higher than those in hard group(all P<0.05),while the variance,the kurtosis and the skewness were not significantly different between groups(all P>0.05).The differentiating efficiency of P 1,P 10,P 50,P 90,P 99 and the mean grey levels on T2WI were all fine,with AUC of 0.774 to 0.833,and no significant difference was found(all P>0.05).Conclusion Parameters of grey-level histogram analysis such as P 1,P 10,P 50,P 90,P 99 and the mean values based on T2WI were all valuable for differentiating soft and hard meningioma.展开更多
Objective To observe the value of long TR three-dimensional inversion recovery sequence with real reconstruction(3D real IR)for quantifying inner ear endolymphatic hydrops(EH).Methods Totally 46 Ménière'...Objective To observe the value of long TR three-dimensional inversion recovery sequence with real reconstruction(3D real IR)for quantifying inner ear endolymphatic hydrops(EH).Methods Totally 46 Ménière's disease(MD)patients and 21 healthy volunteers were prospectively enrolled.MR scanning for inner ear based on 3D real IR and 3D fluid attenuated inversion recovery(3D FLAIR)sequence 4—6 h after administration of contrast agents were performed.The imaging qualities were scored and compared between groups.The endolymphatic space area and the membranous labyrinth area of cochlea and vestibule,as well as endolymph/membranous labyrinth area percentage were calculated,the present or not of EH and the grade of EH were evaluated.EH inner ears of MD patients were enrolled in EH group,while inner ears of healthy volunteers were taken as controls(control group).The endolymphatic space area,membranous labyrinth area and endolymph/membranous labyrinth area percentage of cochlea and vestibule were compared between groups.The receiver operating characteristic(ROC)curve was drawn to calculate the diagnostic efficacy of the above indexes.Results Cochlear and/or vestibular EH were detected in 56 ears,including cochlear EH in 52 ears and vestibular EH in 45 ears among 46 MD patients(EH group),but not in 42 ears in control group.The subjective quality scores of 3D real IR images were higher than those of 3D-FLAIR(both P<0.05).Quantitative analysis based on 3D real IR images revealed that,compared with control group,significantly larger endolymph areas and endolymph/membranous labyrinth area percentages in both cochlea and vestibule were found in EH group(all P<0.001).The area under the curve(AUC)of cochlear or vestibular endolymph/membranous labyrinth area percentage for identifying inner ear EH was 0.999 and 0.985,respectively.Taken 13.64%and 24.13%as the critical value of cochlear or vestibular endolymph,the specificity was 100%and 92.86%,respectively,and the sensitivity was 96.43%and 96.43%,respectively.Conclusion MR long TR 3D real IR was helpful to quantifying inner ear EH.展开更多
目的探讨商业化软件计算球后脂肪体积,分析其与甲状腺相关性眼病(TAO)进展及预后的关系。方法收集2016年1月~2016年12月在我院内分泌科确诊的35例(70个眼眶)TAO患者的临床资料。测量1.5T眼眶MRI球后脂肪体积及眼外肌信号强度比值(SIR)...目的探讨商业化软件计算球后脂肪体积,分析其与甲状腺相关性眼病(TAO)进展及预后的关系。方法收集2016年1月~2016年12月在我院内分泌科确诊的35例(70个眼眶)TAO患者的临床资料。测量1.5T眼眶MRI球后脂肪体积及眼外肌信号强度比值(SIR)分析其与临床各项指标的相关性,并收集12例(24个眼眶)健康人测量球后脂肪体积,初步比较TAO组及健康组体积的差异。结果脂肪体积与病程成正相关(r=0.480,P<0.01),病程6个月以内组与6~12个月组相比,脂肪体积差异不显著(P=0.084)。病程6个月以内组及病程6~12个月组球后脂肪体积均显著低于病程大于12个月组(P<0.01,P<0.05)。脂肪体积与突眼度存在相关性(r=0.622,P<0.01),突眼度每增加1 mm,球后脂肪体积将增加0.88 m L。临床活动性评分(CAS)与SIR值及促甲状腺素受体抗体(TRAb)存在相关性(r=0.536,r=0.416,P<0.01)。TAO组球后脂肪体积显著高于正常组(P<0.01)。结论 TAO病程1年以上可能是球后脂肪组织增多的高峰阶段,球后脂肪体积结合SIR值的测量有助于最佳激素治疗时机的探索及预后分析。展开更多
Dempster-Shafer evidence theory(DS theory) is widely used in brain magnetic resonance imaging(MRI) segmentation,due to its efficient combination of the evidence from different sources. In this paper, an improved MRI s...Dempster-Shafer evidence theory(DS theory) is widely used in brain magnetic resonance imaging(MRI) segmentation,due to its efficient combination of the evidence from different sources. In this paper, an improved MRI segmentation method,which is based on fuzzy c-means(FCM) and DS theory, is proposed. Firstly, the average fusion method is used to reduce the uncertainty and the conflict information in the pictures. Then, the neighborhood information and the different influences of spatial location of neighborhood pixels are taken into consideration to handle the spatial information. Finally, the segmentation and the sensor data fusion are achieved by using the DS theory. The simulated images and the MRI images illustrate that our proposed method is more effective in image segmentation.展开更多
Multi-modality medical image fusion has more and more important applications in medical image analysis and understanding. In this paper, we develop and apply a multi-resolution method based on wavelet pyramid to fuse ...Multi-modality medical image fusion has more and more important applications in medical image analysis and understanding. In this paper, we develop and apply a multi-resolution method based on wavelet pyramid to fuse medical images from different modalities such as PET-MRI and CT-MRI. In particular, we evaluate the different fusion results when applying different selection rules and obtain optimum combination of fusion parameters.展开更多
Magnetic nanoparticles (Fe304) were prepared by chemical precipitation method using Fe^2+ and Fe^3+ salts with sodium hydroxide in the nitrogen atmosphere. Fe3O4 nanoparticles were coated with human serum albumin...Magnetic nanoparticles (Fe304) were prepared by chemical precipitation method using Fe^2+ and Fe^3+ salts with sodium hydroxide in the nitrogen atmosphere. Fe3O4 nanoparticles were coated with human serum albumin(HSA) for magnetic resonance imaging as contrast agent. Characteristics of magnetic particles coated or uncoated were carried out using scanning electron microscopy and X-ray diffraction. Zeta potentials, package effects and distributions of colloid particles were measured to confirm the attachment of HSA on magnetic particles. Effects of Fe3O4 nanoparticles coated with HSA on magnetic resonance imaging were investigated with rats. The experimental results show that the adsorption of HSA on magnetic particles is very favorable to dispersing of magnetic Fe3O4 particles, while the sizes of Fe3O4 particles coated are related to the molar ratio of Fe3O4 to HSA. The diameters of the majority of particles coated are less than 100 nm. Fe3O4 nanoparticle coated with HSA has a good biocompatibility and low toxicity. This new contrast agent has some effects on the nuclear magnetic resonance imaging of liver and the lowest dosage is 20μmol/kg for the demands of diagnosis.展开更多
文摘Objective To qualitatively assess the diagnostic performance of dynamic contrast enhancement(DCE),diffusionweighted imaging(DWI),and T2-weighted imaging(T2WI),alone or in combination,in the evaluation of breast cancer.Methods We retrospectively reviewed the records of 394 consecutive patients with pathologically confirmed breast lesions who had undergone 3-T magnetic resonance imaging(MRI).The morphological characteristics of breast lesions were evaluated using DCE,DWI,and T2WI based on BI-RADS lexicon descriptors by trained radiologists.Patients were categorized into mass and non-mass groups based on MRI characteristics of the lesions,and the differences between benign and malignant lesions in each group were compared.Clinical prediction models for breast cancer diagnosis were constructed using logistic regression analysis.Diagnostic efficacies were compared using the area under the receiver operating characteristic curve(AUC)and DeLong test.Results For mass-like lesions,all the morphological parameters significantly differentiated benign and malignant lesions on consensus DCE,DWI,and T2WI(P<0.05).The combined method(DCE+DWI+T2WI)had a higher AUC(0.865)than any of the individual modality(DCE:0.786;DWI:0.793;T2WI:0.809)(P<0.05).For non-mass-like lesions,DWI signal intensity was a significant predictor of malignancy(P=0.036),but the model using DWI alone had a low AUC(0.669).Conclusion Morphological assessment using the combination of DCE,DWI,and T2WI provides better diagnostic value in differentiating benign and malignant breast mass-like lesions than assessment with only one of the modalities.
文摘Objective To explore the correlations of transcranial sonography of substantia nigra(SN-TCS)characteristics with MRI iron deposition on substantia nigra in patients with Parkinson disease(PD).Methods Data of SN-TCS and craniocerebral MRI in 120 PD patients were retrospectively analyzed.The patients were divided into iron deposition positive group(positive group,n=46)and iron deposition negative group(negative group,n=74)according to quantitative susceptibility mapping(QSM)value.Then parameters of SN-TCS and MRI were compared between groups(both P<0.05),and correlation analysis were also performed.Results The proportion of high echo positive,strong echo area and QSM value of substantia nigra,as well as of hyper-substantia nigra area/midbrain area(S/M)in positive group were all higher than those in negative group(all P<0.001).No significant difference of midbrain area was found between groups(P>0.05).Strong echo area of substantia nigra and S/M based on SN-TCS were both low-medium positively correlated with substantia nigra QSM value showed on MRI(r=0.497,0.529,both P<0.001).Conclusion SN-TCS characteristics of PD patients were correlated with MRI iron deposition on substantia nigra,among which strong echo area and S/M were valuable for evaluating iron deposition on substantia nigra.
文摘Alzheimer's disease(AD)is a prevalent neurodegenerative disease characterized by cognitive decline in the early stage.Mild cognitive impairment(MCI)is considered as an intermediate stage between normal aging and AD.In recent years,studies related to resting-state functional MRI(rs-fMRI)indicated that the occurrence and development process of MCI and AD might be closely linked to spontaneous brain activity and alterations in functional connectivity among brain regions,and rs-fMRI could provide important reference for specific diagnosis and early treatment of MCI and AD.The research progresses of rs-fMRI for MCI and AD were reviewed in this article.
文摘Objective To observe the clinical application value of total free-breathing cardiac MR(CMR)examination preliminarily.Methods Two patients who underwent CMR scanning under free-breathing state,including cine,motion correction T1 and T2 mapping,blood flow imaging,and late gadolinium enhancement scanning were retrospectively enrolled,and the qualities of the above images were evaluated and compared with that of conventional CMR images under breath-holding state.Results No significant difference of imaging quality was found between total free-breathing and conventional breath-holding CMR.The differences of left ventricular ejection fraction,cardiac output,left ventricular end-diastolic volume index and left ventricular mass measured based on CMR images under different breath conditions were limited.Conclusion Total free-breathing CMR was feasible in clinical practice,which could provide"one-stop"evaluation of cardiac structure,function and myocardial histological characteristics,hence having promising clinical prospects.
文摘Objective To observe the value of isotropic volumetric MRI for displaying perineural spread(PNS)of cranial nerve(CN)in nasopharyngeal carcinoma.Methods Eighty-seven patients with pathologically proven nasopharyngeal carcinoma were prospectively enrolled.MR scanning,including three-dimensional liver acquisition with volume acceleration-flexible(3D LAVA_Flex)image,T2WI with fat suppression(T2WI-FS),T1WI,contrast enhancement(CE)T1WI-FS of nasopharynx and neck region were performed.The displaying rates of CN PNS were evaluated and compared between 3D LAVA_Flex and T2WI-FS,T1WI,CE-T1WI-FS at patient level,CN group level and neural level,respectively.Results The displaying rate of CN PNS in all 87 nasopharyngeal carcinoma patients by 3D LAVA_Flex sequence was 49.43%(43/87),higher than that of conventional MRI(30/87,34.48%,P=0.001).Among 59 patients with advanced nasopharyngeal carcinoma diagnosed with conventional sequences,the displaying rate of CN PNS was 71.19%(42/59)by 3D LAVA-Flex sequence,higher than that of conventional MRI(30/59,50.85%,P=0.001).At both patient level and posterior CN level,significant differences of the displaying rate of CN PNS were found between 3D LAVA-Flex sequence and T2WI-FS,T1WI,CE-T1WI-FS,while at CN level,the displaying rates of mandibular nerve PNS,CNⅨ—ⅪPNS in jugular foramen(P<0.05)and CNⅨ—ⅫPNS in carotid space of 3D LAVA_Flex sequence were all significantly higher than that of T2WI-FS,T1WI and CE-T1WI-FS(all P<0.05),of PNS of CNⅢ—Ⅴin cavernous sinus were higher than that of T2WI-FS(P<0.05),while of PNS of hypoglossal nerve were significantly higher than that of T2WI-FS and T1WI(both P<0.05).Conclusion 3D LAVA_Flex sequence could be used to effectively display CN PNS of nasopharyngeal carcinoma.
文摘Objective To observe the value of intravoxel incoherent motion(IVIM)and dynamic contrast-enhanced MRI(DCE-MRI)for assessing abnormalities of brucellosis spondylitis(BS)without conventional MRI changes.Methods Data of 36 brucellosis patients with definite spinal lesions displayed on conventional MRI(BS 1 group),14 cases without brucellosis infection nor abnormal spinal signals on MRI(control group)and 36 brucellosis patients without definite spinal lesions on conventional MRI(BS 2 group)were retrospectively analyzed.The values of IVIM parameters,including perfusion fraction(f),pure water diffusion coefficient(D)and pseudo-diffusion coefficient(D*),also of DCE-MRI parameters,including time-intensity curve(TIC)type,volume transport constant(K trans),the rate constant(K ep)and volume fraction of extravascular extracellular space per unit tissue volume(V e)were compared among groups.Univariate and multivariate logistic regression were used to screen independent factors for discriminating BS 1 and BS 2.Receiver operating characteristic curves were drawn,and the areas under the curve(AUC)were calculated to evaluate the efficiency of the above parameters for discriminating BS 1 and BS 2.Results Among IVIM parameters,compared with control group,D*values decreased but D values increased in BS 1 group,while D*values increased in BS 2 group(all adjusted P<0.05).Compared with BS 2 group,BS 1 group had higher values of f and D and lower D*(all adjusted P<0.05).In BS 1 group,the TIC types were predominantly typeⅠ(23/36,63.89%),which were wholly or predominantly typeⅢin BS 2 group and control group,and of the former was significantly different with latter 2(both adjusted P<0.05).Compared with control group,K trans increased progressively in both BS 1 and BS 2 groups(both adjusted P<0.05).BS 1 group had lower K ep and higher V e than BS 2 and control groups(all adjusted P<0.05).Among univariate logistic regression models,the model including only f had lower capability for discriminating BS 1 and BS 2(AUC=0.759)than those including D,K trans and V e(AUC=0.951,0.833,0.894,all P<0.05).No significant different was found among multivariate logistic regression model including f and D,model including K trans and V e nor model including all above parameters(all P>0.05).Conclusion Both IVIM and DCE-MRI could be used to evaluate BS abnormality without conventional MRI changes.
文摘The incidence of lumbar degenerative diseases is increasing year by year,and MRI is often used in clinical diagnosis.In recent years,artificial intelligence(AI)has rapidly developed in medical field and can be used for image segmentation and auxiliary diagnosis of lumbar degenerative diseases.The research progresses of AI in MRI of lumbar degenerative diseases were reviewed in this article.
文摘Objective To observe the value of grey-level histogram analysis based on T2WI for differentiating consistency of meningioma.Methods Data of 109 patients with meningioma were retrospectively analyzed.The patients were divided into hard group(n=71)and soft group(n=38)according to the consistency of tumors.Tumor ROI was outlined on axial T2WI showing the largest tumor section,gray levels were extracted and histogram analysis was performed.The value of each histogram parameter were compared between groups.Then receiver operating characteristic curve was drawn,and the area under the curve(AUC)was calculated to evaluate the efficiency for differentiating soft and hard meningioma.Results P 1,P 10,P 50,P 90,P 99 and the mean grey levels on T2WI in soft group were all higher than those in hard group(all P<0.05),while the variance,the kurtosis and the skewness were not significantly different between groups(all P>0.05).The differentiating efficiency of P 1,P 10,P 50,P 90,P 99 and the mean grey levels on T2WI were all fine,with AUC of 0.774 to 0.833,and no significant difference was found(all P>0.05).Conclusion Parameters of grey-level histogram analysis such as P 1,P 10,P 50,P 90,P 99 and the mean values based on T2WI were all valuable for differentiating soft and hard meningioma.
文摘Objective To observe the value of long TR three-dimensional inversion recovery sequence with real reconstruction(3D real IR)for quantifying inner ear endolymphatic hydrops(EH).Methods Totally 46 Ménière's disease(MD)patients and 21 healthy volunteers were prospectively enrolled.MR scanning for inner ear based on 3D real IR and 3D fluid attenuated inversion recovery(3D FLAIR)sequence 4—6 h after administration of contrast agents were performed.The imaging qualities were scored and compared between groups.The endolymphatic space area and the membranous labyrinth area of cochlea and vestibule,as well as endolymph/membranous labyrinth area percentage were calculated,the present or not of EH and the grade of EH were evaluated.EH inner ears of MD patients were enrolled in EH group,while inner ears of healthy volunteers were taken as controls(control group).The endolymphatic space area,membranous labyrinth area and endolymph/membranous labyrinth area percentage of cochlea and vestibule were compared between groups.The receiver operating characteristic(ROC)curve was drawn to calculate the diagnostic efficacy of the above indexes.Results Cochlear and/or vestibular EH were detected in 56 ears,including cochlear EH in 52 ears and vestibular EH in 45 ears among 46 MD patients(EH group),but not in 42 ears in control group.The subjective quality scores of 3D real IR images were higher than those of 3D-FLAIR(both P<0.05).Quantitative analysis based on 3D real IR images revealed that,compared with control group,significantly larger endolymph areas and endolymph/membranous labyrinth area percentages in both cochlea and vestibule were found in EH group(all P<0.001).The area under the curve(AUC)of cochlear or vestibular endolymph/membranous labyrinth area percentage for identifying inner ear EH was 0.999 and 0.985,respectively.Taken 13.64%and 24.13%as the critical value of cochlear or vestibular endolymph,the specificity was 100%and 92.86%,respectively,and the sensitivity was 96.43%and 96.43%,respectively.Conclusion MR long TR 3D real IR was helpful to quantifying inner ear EH.
文摘目的探讨商业化软件计算球后脂肪体积,分析其与甲状腺相关性眼病(TAO)进展及预后的关系。方法收集2016年1月~2016年12月在我院内分泌科确诊的35例(70个眼眶)TAO患者的临床资料。测量1.5T眼眶MRI球后脂肪体积及眼外肌信号强度比值(SIR)分析其与临床各项指标的相关性,并收集12例(24个眼眶)健康人测量球后脂肪体积,初步比较TAO组及健康组体积的差异。结果脂肪体积与病程成正相关(r=0.480,P<0.01),病程6个月以内组与6~12个月组相比,脂肪体积差异不显著(P=0.084)。病程6个月以内组及病程6~12个月组球后脂肪体积均显著低于病程大于12个月组(P<0.01,P<0.05)。脂肪体积与突眼度存在相关性(r=0.622,P<0.01),突眼度每增加1 mm,球后脂肪体积将增加0.88 m L。临床活动性评分(CAS)与SIR值及促甲状腺素受体抗体(TRAb)存在相关性(r=0.536,r=0.416,P<0.01)。TAO组球后脂肪体积显著高于正常组(P<0.01)。结论 TAO病程1年以上可能是球后脂肪组织增多的高峰阶段,球后脂肪体积结合SIR值的测量有助于最佳激素治疗时机的探索及预后分析。
基金supported by the National Natural Science Foundation of China(6167138461703338)+2 种基金the Natural Science Basic Research Plan in Shaanxi Province of China(2016JM6018)the Project of Science and Technology Foundationthe Fundamental Research Funds for the Central Universities(3102017OQD020)
文摘Dempster-Shafer evidence theory(DS theory) is widely used in brain magnetic resonance imaging(MRI) segmentation,due to its efficient combination of the evidence from different sources. In this paper, an improved MRI segmentation method,which is based on fuzzy c-means(FCM) and DS theory, is proposed. Firstly, the average fusion method is used to reduce the uncertainty and the conflict information in the pictures. Then, the neighborhood information and the different influences of spatial location of neighborhood pixels are taken into consideration to handle the spatial information. Finally, the segmentation and the sensor data fusion are achieved by using the DS theory. The simulated images and the MRI images illustrate that our proposed method is more effective in image segmentation.
基金the National Natural Science Foundation of China (No. 19675005).
文摘Multi-modality medical image fusion has more and more important applications in medical image analysis and understanding. In this paper, we develop and apply a multi-resolution method based on wavelet pyramid to fuse medical images from different modalities such as PET-MRI and CT-MRI. In particular, we evaluate the different fusion results when applying different selection rules and obtain optimum combination of fusion parameters.
文摘Magnetic nanoparticles (Fe304) were prepared by chemical precipitation method using Fe^2+ and Fe^3+ salts with sodium hydroxide in the nitrogen atmosphere. Fe3O4 nanoparticles were coated with human serum albumin(HSA) for magnetic resonance imaging as contrast agent. Characteristics of magnetic particles coated or uncoated were carried out using scanning electron microscopy and X-ray diffraction. Zeta potentials, package effects and distributions of colloid particles were measured to confirm the attachment of HSA on magnetic particles. Effects of Fe3O4 nanoparticles coated with HSA on magnetic resonance imaging were investigated with rats. The experimental results show that the adsorption of HSA on magnetic particles is very favorable to dispersing of magnetic Fe3O4 particles, while the sizes of Fe3O4 particles coated are related to the molar ratio of Fe3O4 to HSA. The diameters of the majority of particles coated are less than 100 nm. Fe3O4 nanoparticle coated with HSA has a good biocompatibility and low toxicity. This new contrast agent has some effects on the nuclear magnetic resonance imaging of liver and the lowest dosage is 20μmol/kg for the demands of diagnosis.