期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Time-resolved ultra-small-angle X-ray scattering beamline(BL10U1)at SSRF
1
作者 Wen-Qiang Hua Chun-Ming Yang +12 位作者 Ping Zhou Feng Tian Jin-You Lin Yu-Zhu Wang Xiao-Yun Li Xia-Ran Miao Chun-Xia Hong Qiu-Shi Huang Xin-Tong Zhao Yong-Feng Men Jie Wang Xing-Yu Gao Xiu-Hong Li 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第2期6-19,共14页
The construction of a new beamline,BL10U1,was completed at the Shanghai synchrotron radiation facility in 2020.This multipurpose beamline was designed to provide X-ray scattering techniques such as ultra-small-angle X... The construction of a new beamline,BL10U1,was completed at the Shanghai synchrotron radiation facility in 2020.This multipurpose beamline was designed to provide X-ray scattering techniques such as ultra-small-angle X-ray scattering(USAXS),small-angle X-ray scattering(SAXS),wide-angle X-ray scattering,and microfocus SAXS(μSAXS)for a broad user community.To realize fast time-resolved USAXS experiments,the beamline adopted an in-vacuum undulator with a total length of 1.6 m as the photon source.An in-house cryogenic-cooled double multilayer monochromator was installed to deliver a photon flux of approximately 10^(13) photons/s at a photon energy of 10 keV.The three-year successful operation of this beamline demonstrated that the monochromator operated smoothly,as expected.BL10U1 has three end stations in succession:USAXS end station,μSAXS end station,and end station for industrial applications.The minimum scattering vector q~0.0042 nm^(-1) at 10 keV can be achieved at the USAXS end station equipped with a 28 m-long and 1.8 m-diameter vacuum flight tube.At theμSAXS end station,a beam spot of less than 10×8μm was achieved for micro-SAXS experiments.In contrast,in situ experimental instruments up to 5 m high and 8 m wide can be mounted at the industrial application end station,which offers industrial scientists the opportunity to use their large industrial equipment.BL10U1 opens up a new capability to investigate phenomena such as non-equilibrium and dynamic processes of materials with a wide length scale from angstroms to micrometers with millisecond time resolution.In this paper,we also report beamline design considerations and commissioning results. 展开更多
关键词 Synchrotron radiation Ultra-small-angle X-ray scattering Micro small-angle X-ray scattering USAXS time resolved μSAXS
在线阅读 下载PDF
垂直及斜出水流场的二维及三维TR-PIV试验 被引量:12
2
作者 张军 李英浩 金朋寿 《船舶力学》 EI 北大核心 2005年第2期9-17,共9页
本文对钝头回转体垂直及斜出水流场采用TR-(Time-Resolved)PIV技术进行测量,并对斜出水流场进行3D-StereoPIV(三维体视PIV)测量。文中介绍了测试技术及测量结果,揭示了出水过程中流动结构及其演变,展示了TR-PIV技术对具有瞬态历程特征... 本文对钝头回转体垂直及斜出水流场采用TR-(Time-Resolved)PIV技术进行测量,并对斜出水流场进行3D-StereoPIV(三维体视PIV)测量。文中介绍了测试技术及测量结果,揭示了出水过程中流动结构及其演变,展示了TR-PIV技术对具有瞬态历程特征的出水流场研究的适应性。 展开更多
关键词 出水 time—Resolved PIV:3D—Stereo PIV
在线阅读 下载PDF
Fast-sweeping Langmuir probes:what happens to theⅠ–Ⅴtrace when sweeping frequency is higher than the ion plasma frequency? 被引量:1
3
作者 Chenyao JIN chi-shung YIP +2 位作者 Wei ZHANG Di JIANG Guosheng XU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第2期93-106,共14页
Limited particle transit time is one of several limiting factors which determine the maximum temporal resolution of a Langmuir probe.In this work,we have revisited the known fast sweep Langmuir probe techniques in a u... Limited particle transit time is one of several limiting factors which determine the maximum temporal resolution of a Langmuir probe.In this work,we have revisited the known fast sweep Langmuir probe techniques in a uniform,quiescent multi-dipole confined hot cathode discharge with two operation scenarios:one in which the probe sweeping frequency fsweepis much lower than the ion plasma frequency fpi,another one where fsweepis much greater than fpi,respectively.This allows investigation into the effect of limited ion-motion on I–V traces.Serious distortions of I–V traces at high frequencies,previously claimed to be an ion-motion limitation effect,were not found unless shunt resistance is sufficiently high,despite a f;/f;ratio of~3.On the other hand,evidences of sheath capacitance on the I–V traces have been observed.Distortions of I–V traces qualitatively agree with predictions of sheath capacitance response to the sweeping voltage.Additionally,techniques in fast sweep Langmuir probe are briefly discussed.The comparison between the high-speed dual Langmuir probe(HDLP)and the single probe setup shows that the capacitive response can be removed via subtracting a leakage current for the single probe setup almost as effectively as using the HDLP setup,but the HDLP setup does remain advantageous in its facilitation of better recovery of weak current signal commonly in low density plasma. 展开更多
关键词 high speed diagnostics time resolved diagnostics Langmuir probe
在线阅读 下载PDF
Exciton emission dynamics in single InAs/GaAs quantum dots due to the existence of plasmon-field-induced metastable states in the wetting layer
4
作者 Junhui Huang Hao Chen +8 位作者 Zhiyao Zhuo Jian Wang Shulun Li Kun Ding Haiqiao Ni Zhichuan Niu Desheng Jiang Xiuming Dou Baoquan Sun 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第9期552-557,共6页
A very long lifetime exciton emission with non-single exponential decay characteristics has been reported for single InA-s/GaAs quantum dot(QD)samples,in which there exists a long-lived metastable state in the wetting... A very long lifetime exciton emission with non-single exponential decay characteristics has been reported for single InA-s/GaAs quantum dot(QD)samples,in which there exists a long-lived metastable state in the wetting layer(WL)through radiative field coupling between the exciton emissions in the WL and the dipole field of metal islands.In this article we have proposed a new three-level model to simulate the exciton emission decay curve.In this model,assuming that the excitons in a metastable state will diffuse and be trapped by QDs,and then emit fluorescence in QDs,a stretchedlike exponential decay formula is derived as I(t)=At^(β−1)e^(−(rt)^(β)),which can describe well the long lifetime decay curve with an analytical expression of average lifetime(τ)=1/rГ(1/β+1),where G is the Gamma function.Furthermore,based on the proposed three-level model,an expression of the second-order auto-correlation function g^(2)(t)which can fit the measured g^(2)(t)curve well,is also obtained. 展开更多
关键词 quantum dots collective excitations charge carriers time resolved spectroscopy
在线阅读 下载PDF
Temperature dependent terahertz giant anisotropy and cycloidal spin wave modes in BiFeO3 single crystal
5
作者 Fan Liu Zuanming Jin +6 位作者 Xiumei Liu Yuqing Fang Jiajia Guo Yan Peng Zhenxiang Cheng Guohong Ma Yiming Zhu 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第7期135-140,共6页
THz time-domain spectroscopy(THz-TDS)is used to study the THz-optical properties of a single crystal bismuth ferrite BiFeO3(BFO).It can be found that the anisotropy of BiFeO3 is strongly dependent on the temperature.A... THz time-domain spectroscopy(THz-TDS)is used to study the THz-optical properties of a single crystal bismuth ferrite BiFeO3(BFO).It can be found that the anisotropy of BiFeO3 is strongly dependent on the temperature.A giant birefringence up to around 3.6 is observed at 1 THz.The presence of a spatially modulated cycloidal antiferromagnetic structure leads to spin cycloid resonances(SCR)ψandΦ,corresponding to the out-of-plane and in-plane modes of the spin cycloid,respectively.We distinguish the SCR with respect to their response to orthogonal polarizations of the electric fields of the incident THz beam.In addition,we observe a resonance appearing below 140 K,which might be interpreted as an electromagnon mode and related to a spin reorientation transition.Our present observations present that the temperature and polarization,as the external control parameters,can be used to modulate the THz optical properties of BFO single crystal. 展开更多
关键词 time resolved terahertz spectroscopy dielectric anisotropy spin cycloid resonance
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部