Recently,unmanned aerial vehicle(UAV)-aided free-space optical(FSO)communication has attracted widespread attentions.However,most of the existing research focuses on communication performance only.The authors investig...Recently,unmanned aerial vehicle(UAV)-aided free-space optical(FSO)communication has attracted widespread attentions.However,most of the existing research focuses on communication performance only.The authors investigate the integrated scheduling of communication,sensing,and control for UAV-aided FSO communication systems.Initially,a sensing-control model is established via the control theory.Moreover,an FSO communication channel model is established by considering the effects of atmospheric loss,atmospheric turbulence,geometrical loss,and angle-of-arrival fluctuation.Then,the relationship between the motion control of the UAV and radial displacement is obtained to link the control aspect and communication aspect.Assuming that the base station has instantaneous channel state information(CSI)or statistical CSI,the thresholds of the sensing-control pattern activation are designed,respectively.Finally,an integrated scheduling scheme for performing communication,sensing,and control is proposed.Numerical results indicate that,compared with conventional time-triggered scheme,the proposed integrated scheduling scheme obtains comparable communication and control performance,but reduces the sensing consumed power by 52.46%.展开更多
The accuracy of spot centroid positioning has a significant impact on the tracking accuracy of the system and the stability of the laser link construction.In satellite laser communication systems,the use of short-wave...The accuracy of spot centroid positioning has a significant impact on the tracking accuracy of the system and the stability of the laser link construction.In satellite laser communication systems,the use of short-wave infrared wavelengths as beacon light can reduce atmospheric absorption and signal attenuation.However,there are strong non-uniformity and blind pixels in the short-wave infrared image,which makes the image distorted and leads to the decrease of spot centroid positioning accuracy.Therefore,the high-precision localization of the spot centroid of the short-wave infrared images is of great research significance.A high-precision spot centroid positioning model for short-wave infrared is proposed to correct for non-uniformity and blind pixels in short-wave infrared images and quantify the localization errors caused by the two,further model-based localization error simulations are performed,and a novel spot centroid positioning payload for satellite laser communications has been designed using the latest 640×512 planar array InGaAs shortwave infrared detector.The experimental results show that the non-uniformity of the corrected image is reduced from 7%to 0.6%,the blind pixels rejection rate reaches 100%,the frame rate can be up to 2000 Hz,and the spot centroid localization accuracy is as high as 0.1 pixel point,which realizes high-precision spot centroid localization of high-frame-frequency short-wave infrared images.展开更多
The Underwater Communication Link(UCL)is a crucial component of Underwater Wireless Optical Communication(UWOC)systems,requiring optimised design to mitigate the high power attenuation inherent in seawater.To ensure t...The Underwater Communication Link(UCL)is a crucial component of Underwater Wireless Optical Communication(UWOC)systems,requiring optimised design to mitigate the high power attenuation inherent in seawater.To ensure the reliability of an optimal UCL design,it is essential to account for the three primary scattering regimes:forward scattering(FSC),backward scattering(BSC),and isotropic scattering(ISC)in seawater channels.This study introduces a new photon-tracking model based on a discrete equation,facilitating Monte Carlo Simulation(MCS)to evaluate how different scattering regimes influence received photon distribution.Three distinct Scattering Regime Contribution Weight(SRCW)probability sets were employed,each representing different UCL operational configurations dominated by specific scattering regimes.The proposed modeling approach enables a comprehensive assessment of the temporal characteristics of received optical pulses,channel loss,and time spread-ultimately defining the optimal UCL design parameters.The key findings of this study include:(1)Enhancing the FSC regime dominance leads to a quasi-light waveguide effect over link spans and small Fields of View(FOV)<25°,significantly improving channel performance in Harbor seawater compared to Coastal seawater.(2)A well-designed UCL with a small FOV(<25°)can minimise channel loss and time spread,ensuring high capacity and efficient performance in both Coastal and Harbor seawaters.(3)When BSC and ISC contributions exceed FSC dominance,the received optical pulse undergoes significant temporal broadening,particularly for larger FOV angles(>25°)and extended link spans.(4)The developed novel MCS-based discrete equation provides a simple yet robust model for simulating photon propagation in both homogeneous and inhomogeneous underwater channels.These insights contribute to developing more efficient and reliable UCL designs with military standards by enhancing UWOC system performance over a longer linkspan for a given limited optical power across various underwater environments.展开更多
应用SYBR Green I染料能选择性结合双链DNA的特点,可检测到沙门氏菌fimI基因特异性靶序列扩增所产生的荧光信号,通过熔解曲线可知其熔点值约为85.6℃,而对其他非沙门氏菌则检测不到荧光信号。建立了一种肉品中的沙门氏菌Real-time PCR...应用SYBR Green I染料能选择性结合双链DNA的特点,可检测到沙门氏菌fimI基因特异性靶序列扩增所产生的荧光信号,通过熔解曲线可知其熔点值约为85.6℃,而对其他非沙门氏菌则检测不到荧光信号。建立了一种肉品中的沙门氏菌Real-time PCR检测方法,用该方法检测市售牛肉、香肠中的沙门氏菌,其检测灵敏度分别为13,12 cfu/25 g,从样品的处理到得出检验结果可以在10 h内完成。该检测方法具有简便、快速、特异性强、敏感度高等特点。展开更多
目的建立快速、特异性好、灵敏度高的Real-Time PCR方法定量检测沙门菌。方法根据编码沙门菌肠毒素基因stn的核苷酸序列,设计荧光探针和一对引物,通过对荧光定量PCR反应体系和反应条件的摸索,建立定量检测沙门菌的方法。结果建立的Real-...目的建立快速、特异性好、灵敏度高的Real-Time PCR方法定量检测沙门菌。方法根据编码沙门菌肠毒素基因stn的核苷酸序列,设计荧光探针和一对引物,通过对荧光定量PCR反应体系和反应条件的摸索,建立定量检测沙门菌的方法。结果建立的Real-Ti me PCR方法有很好的特异性与敏感性,所检测沙门菌结果均为阳性,而非沙门菌均为阴性;标准曲线相关系数为R2=0.993,其敏感性为5CFU。运用该方法对108份鸡粪便、50份鸡肉以及58份水样进行检测,阳性率分别为3.7%(6/108)、4%(2/50)和3.4%(2/58),与传统细菌分离检测结果相符。结论结果表明该方法具有简便、快速、特异性强、敏感性高等特点,此研究为环境及疾病诊断中沙门菌快速检测提供了新方法。展开更多
文摘16.09.06‐NI (美国国家仪器公司,National Instruments ,简称NI)作为致力于为工程师和科学家提供解决方案来应对全球最严峻的工程挑战的供应商,宣布推出LabVIEW Communications系统设计套件2.0这一个专门用于无线通信系统原型开发的设计环境。新版本增加了NI Linux Real‐Time 功能,适用于所有软件定义无线电(SDR)产品,包括NI USRP RIO 和FlexRIO 。新增的功能可帮助工程师开发在 NI Linux Real‐Time 操作系统上运行实时算法,并与其他工具搭配使用,将协议栈上移到M AC层和网络层,同时访问搭建完整系统原型所需要的庞大的开源工具和技术库,系统原型的搭建是推进5G 项目的关键。
文摘Recently,unmanned aerial vehicle(UAV)-aided free-space optical(FSO)communication has attracted widespread attentions.However,most of the existing research focuses on communication performance only.The authors investigate the integrated scheduling of communication,sensing,and control for UAV-aided FSO communication systems.Initially,a sensing-control model is established via the control theory.Moreover,an FSO communication channel model is established by considering the effects of atmospheric loss,atmospheric turbulence,geometrical loss,and angle-of-arrival fluctuation.Then,the relationship between the motion control of the UAV and radial displacement is obtained to link the control aspect and communication aspect.Assuming that the base station has instantaneous channel state information(CSI)or statistical CSI,the thresholds of the sensing-control pattern activation are designed,respectively.Finally,an integrated scheduling scheme for performing communication,sensing,and control is proposed.Numerical results indicate that,compared with conventional time-triggered scheme,the proposed integrated scheduling scheme obtains comparable communication and control performance,but reduces the sensing consumed power by 52.46%.
基金Supported by the Short-wave Infrared Camera Systems(B025F40622024)。
文摘The accuracy of spot centroid positioning has a significant impact on the tracking accuracy of the system and the stability of the laser link construction.In satellite laser communication systems,the use of short-wave infrared wavelengths as beacon light can reduce atmospheric absorption and signal attenuation.However,there are strong non-uniformity and blind pixels in the short-wave infrared image,which makes the image distorted and leads to the decrease of spot centroid positioning accuracy.Therefore,the high-precision localization of the spot centroid of the short-wave infrared images is of great research significance.A high-precision spot centroid positioning model for short-wave infrared is proposed to correct for non-uniformity and blind pixels in short-wave infrared images and quantify the localization errors caused by the two,further model-based localization error simulations are performed,and a novel spot centroid positioning payload for satellite laser communications has been designed using the latest 640×512 planar array InGaAs shortwave infrared detector.The experimental results show that the non-uniformity of the corrected image is reduced from 7%to 0.6%,the blind pixels rejection rate reaches 100%,the frame rate can be up to 2000 Hz,and the spot centroid localization accuracy is as high as 0.1 pixel point,which realizes high-precision spot centroid localization of high-frame-frequency short-wave infrared images.
基金The Deanship of Scientific Research(DSR)at King Abdulaziz University(KAU),Jeddah,Saudi Arabia,has funded this project under Grant No.(KEP-PhD:72-130-1443).
文摘The Underwater Communication Link(UCL)is a crucial component of Underwater Wireless Optical Communication(UWOC)systems,requiring optimised design to mitigate the high power attenuation inherent in seawater.To ensure the reliability of an optimal UCL design,it is essential to account for the three primary scattering regimes:forward scattering(FSC),backward scattering(BSC),and isotropic scattering(ISC)in seawater channels.This study introduces a new photon-tracking model based on a discrete equation,facilitating Monte Carlo Simulation(MCS)to evaluate how different scattering regimes influence received photon distribution.Three distinct Scattering Regime Contribution Weight(SRCW)probability sets were employed,each representing different UCL operational configurations dominated by specific scattering regimes.The proposed modeling approach enables a comprehensive assessment of the temporal characteristics of received optical pulses,channel loss,and time spread-ultimately defining the optimal UCL design parameters.The key findings of this study include:(1)Enhancing the FSC regime dominance leads to a quasi-light waveguide effect over link spans and small Fields of View(FOV)<25°,significantly improving channel performance in Harbor seawater compared to Coastal seawater.(2)A well-designed UCL with a small FOV(<25°)can minimise channel loss and time spread,ensuring high capacity and efficient performance in both Coastal and Harbor seawaters.(3)When BSC and ISC contributions exceed FSC dominance,the received optical pulse undergoes significant temporal broadening,particularly for larger FOV angles(>25°)and extended link spans.(4)The developed novel MCS-based discrete equation provides a simple yet robust model for simulating photon propagation in both homogeneous and inhomogeneous underwater channels.These insights contribute to developing more efficient and reliable UCL designs with military standards by enhancing UWOC system performance over a longer linkspan for a given limited optical power across various underwater environments.
文摘目的建立快速、特异性好、灵敏度高的Real-Time PCR方法定量检测沙门菌。方法根据编码沙门菌肠毒素基因stn的核苷酸序列,设计荧光探针和一对引物,通过对荧光定量PCR反应体系和反应条件的摸索,建立定量检测沙门菌的方法。结果建立的Real-Ti me PCR方法有很好的特异性与敏感性,所检测沙门菌结果均为阳性,而非沙门菌均为阴性;标准曲线相关系数为R2=0.993,其敏感性为5CFU。运用该方法对108份鸡粪便、50份鸡肉以及58份水样进行检测,阳性率分别为3.7%(6/108)、4%(2/50)和3.4%(2/58),与传统细菌分离检测结果相符。结论结果表明该方法具有简便、快速、特异性强、敏感性高等特点,此研究为环境及疾病诊断中沙门菌快速检测提供了新方法。