In this paper, a strategy for the reactive power compensation and harmonic suppression of the power supply system in HT-7U superconductive Tokamak is proposed. The optimized approach is given in the parameters design...In this paper, a strategy for the reactive power compensation and harmonic suppression of the power supply system in HT-7U superconductive Tokamak is proposed. The optimized approach is given in the parameters design for passive filter. Also a controlling method with fast response time and good accuracy is put forward for the compensator, which is more suitable for the dynamic load.展开更多
Intermittent new energy delivery requires increasing the flexibility of ultra-high voltage direct current(DC)power adjustment.Based on a converter steady-state model and a DC power model,the control angle constraints ...Intermittent new energy delivery requires increasing the flexibility of ultra-high voltage direct current(DC)power adjustment.Based on a converter steady-state model and a DC power model,the control angle constraints of a converter valve are relaxed for power regulation.In this paper,a flexible DC power control method based on a fixed tap changer position is proposed.The initial ratio of the converter transformer is optimized.The effects of the fixed-tap changer position control on the control angle,reactive power compensation,and commutation failure are analyzed.The new control method allows a DC system to operate at a large angle and increase the additional reactive power loss while improving the commutation security margin.Steady-state and electromagnetic transient simulations in the CIGRE test system verify the validity of the method proposed in this paper and the correctness of the analysis conclusions.展开更多
文摘In this paper, a strategy for the reactive power compensation and harmonic suppression of the power supply system in HT-7U superconductive Tokamak is proposed. The optimized approach is given in the parameters design for passive filter. Also a controlling method with fast response time and good accuracy is put forward for the compensator, which is more suitable for the dynamic load.
基金an independent research project from the Shandong Electric Power Research Institute,“Research on the control method of DC power under fixed converter transformer tap-changer position”(ZY-2020-01)Based on the achievement,a national invention patent(No.2020112240143)has been applied.
文摘Intermittent new energy delivery requires increasing the flexibility of ultra-high voltage direct current(DC)power adjustment.Based on a converter steady-state model and a DC power model,the control angle constraints of a converter valve are relaxed for power regulation.In this paper,a flexible DC power control method based on a fixed tap changer position is proposed.The initial ratio of the converter transformer is optimized.The effects of the fixed-tap changer position control on the control angle,reactive power compensation,and commutation failure are analyzed.The new control method allows a DC system to operate at a large angle and increase the additional reactive power loss while improving the commutation security margin.Steady-state and electromagnetic transient simulations in the CIGRE test system verify the validity of the method proposed in this paper and the correctness of the analysis conclusions.