A chemical vapour deposition (CVD) diamond film detector was prepared and the main characteristics for pulsed proton detection were studied at Beijing Tandem Accelerator. The result shows that the charge collection ...A chemical vapour deposition (CVD) diamond film detector was prepared and the main characteristics for pulsed proton detection were studied at Beijing Tandem Accelerator. The result shows that the charge collection efficiency of the detector increases with increasing electric field intensity and reaches to 9.44% at 5 V/μm with the charge collection distance of 15.9 μm. The relationship between the sensitivity of the detector and proton energy is consistent with the Monte Carlo (MC) simulation result. Its plasma time for a pulse with 4.85×10^5 protons is 1l.2ns. The dose threshold for onset of damage under 9MeV proton irradiation in the detector is about 10^13 cm^-2. All of the results show that a CVD diamond detector has fast time response and high radiation hardness, and can be used in pulsed proton detection.展开更多
In optical performance monitoring system,the analog to digital converter is needed to detect the peak of nanosecond pulse and get the signal envelope.A scheme based on a designed anti-aliasing filter and analog to dig...In optical performance monitoring system,the analog to digital converter is needed to detect the peak of nanosecond pulse and get the signal envelope.A scheme based on a designed anti-aliasing filter and analog to digital converter is proposed to broaden the nanosecond pulse and make it easier for the analog to digital converter to catch the peak of the nanosecond pulse.The experimental results demonstrate that,with the proposed scheme,the optical performance system needs less time to get the recovered eye-diagram of high speed optical data signal,and is robust to phase mismatch in the analog to digital converter circuit.展开更多
基金Project supported by the National Natural Science Foundation of China (Grant No 10675074)
文摘A chemical vapour deposition (CVD) diamond film detector was prepared and the main characteristics for pulsed proton detection were studied at Beijing Tandem Accelerator. The result shows that the charge collection efficiency of the detector increases with increasing electric field intensity and reaches to 9.44% at 5 V/μm with the charge collection distance of 15.9 μm. The relationship between the sensitivity of the detector and proton energy is consistent with the Monte Carlo (MC) simulation result. Its plasma time for a pulse with 4.85×10^5 protons is 1l.2ns. The dose threshold for onset of damage under 9MeV proton irradiation in the detector is about 10^13 cm^-2. All of the results show that a CVD diamond detector has fast time response and high radiation hardness, and can be used in pulsed proton detection.
基金supported by National 863 Program of China(2013AA013401),P.R.ChinaNational Natural Science Foundation of China under Grant No.61177067,No.61027007,and No.61331010
文摘In optical performance monitoring system,the analog to digital converter is needed to detect the peak of nanosecond pulse and get the signal envelope.A scheme based on a designed anti-aliasing filter and analog to digital converter is proposed to broaden the nanosecond pulse and make it easier for the analog to digital converter to catch the peak of the nanosecond pulse.The experimental results demonstrate that,with the proposed scheme,the optical performance system needs less time to get the recovered eye-diagram of high speed optical data signal,and is robust to phase mismatch in the analog to digital converter circuit.