The chiral separation of phenylsuccinic acid(PSA)was studied by reversed phase high-performance liquid chromatography(RP-HPLC)with cyclodextrins(CDs)as chiral mobile phase additives.The effects of types of CDs,concent...The chiral separation of phenylsuccinic acid(PSA)was studied by reversed phase high-performance liquid chromatography(RP-HPLC)with cyclodextrins(CDs)as chiral mobile phase additives.The effects of types of CDs,concentration of hydroxypropyl-β-cyclodextrin(HP-β-CD),percentage of organic modifier,pH value and column temperature on enantioselective separation were investigated.The quantification property of the developed RP-HPLC method was examined.The chiral recognition mechanism of PSA was also discussed.The results show that a baseline separation of PSA enantiomers is achieved on a Lichrospher C18 column(4.6 mm(inner diameter)×250 mm,5μm)with HP-β-CD as chiral mobile phase additive.The capacity factors of R-PSA and S-PSA are 3.94 and 4.80,respectively.The separation factor and resolution are respectively 1.22 and 8.03.The mobile phase is a mixture of acetonitrile and deionized water(20-80,volume ratio)containing 10 mmol/L HP-β-CD and 0.05% trifluoroacetic acid(pH 2.5,adjusted with triethylamine)with a flow rate of 1.0 mL/min.The ultraviolet(UV)detector is set at 254 nm.The likely roles are inclusion interaction,induction and hydrogen bonding between HP-β-CD and PSA enantiomers.展开更多
The method of reversed-phase high performance liquid chromatography was established for the determination of effective components in OC-CS spray using double wavelength UV detection.The method was utilized under follo...The method of reversed-phase high performance liquid chromatography was established for the determination of effective components in OC-CS spray using double wavelength UV detection.The method was utilized under following conditions:a column of Kromasil C18(250 mm × 4.6 mm,5 μm),mobile phase consisting of methanol/water(80 /20) at a flow rate of 0.8 mL/min,column temperature of 25 ℃,and the UV detection at 227 nm and 300 nm.Three key components in OC-CS spray could be distinguished clearly,including o-chlorobenzalmalononitrile(CS),oleoresin capsicum(OC) and dihydrocapsaicin(DC).This method has the advantages of fast,simple and satisfactory linear relationship between UV absorption and concentration.It may be considered to turn into a standard method for detection of related components in the spray.展开更多
A high-performance liquid chromatography was describ-ed to measure the concentration of human 3-methylhistidine in urine witho-phthaldialdehyde pre-column derivatization.This assay system resultedin a clear separation...A high-performance liquid chromatography was describ-ed to measure the concentration of human 3-methylhistidine in urine witho-phthaldialdehyde pre-column derivatization.This assay system resultedin a clear separation of 3-methylhistidine derivative from other derivativ-es in urine within 25 min.Linearity,recovery and coefficients of vari-ation were studied.The method has been successfully applied to routineanalysis for clinical studies and diagnosis.展开更多
Modern porous monoliths have been conceived as a new class of stationary phases for high performance liquid chromatography(HPLC) in classical columns in the early 1990s and later extended to the capillary format.These...Modern porous monoliths have been conceived as a new class of stationary phases for high performance liquid chromatography(HPLC) in classical columns in the early 1990s and later extended to the capillary format.These monolithic materials are prepared using simple processes carried out in an external mold(inorganic monoliths) or within the confines of the column(organic monoliths and all capillary columns).These methods afford macroporous materials with large through-pores that enable applications in a rapid flow-through mode.Since all the mobile phase must flow through the monolith,the convection considerably accelerates mass transport within the monolithic separation medium and improves the separations.As a result,the monolithic columns perform well even at very high flow rates.The applications of monolithic capillary columns are demonstrated on numerous separations in the HPLC mode.展开更多
Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC...Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine.展开更多
Development of effective chromatographic or electrophoretic separation involves judicious deciding of selection of optimal experimental conditions that can provide an adequate resolution at a reasonable run time for t...Development of effective chromatographic or electrophoretic separation involves judicious deciding of selection of optimal experimental conditions that can provide an adequate resolution at a reasonable run time for the separation of interested components. Box-Behnken factorial design was effectively applied for the separation optimization of eight structurally related sulfonamides using capillary zone electrophorosis and reverse high performance liquid chromatography. Optimum values for volume ratio of THF to H2O in eluent, column temperature and flow rate of eluent are found as 12 to 88, 35℃ and 1.0 mL/min, respectively. Box-Behnken modified optimization model is extended to separation by capillary electrophoresis (CE). While using CE, a satisfactory separation is achieved with a minimum resolution larger than 1.0 for a separation time less than 10 min.展开更多
为建立一种可同时检测鸽蛋中多类兽药残留的高通量液相色谱-串联质谱法,试验采用正己烷去脂,联合QuEChERS净化结合冷冻脂质过滤法,建立检测鸽蛋中5类24种兽药残留的高效液相色谱-串联质谱法。样品中的5类兽药(氯霉素类、磺胺类、硝基咪...为建立一种可同时检测鸽蛋中多类兽药残留的高通量液相色谱-串联质谱法,试验采用正己烷去脂,联合QuEChERS净化结合冷冻脂质过滤法,建立检测鸽蛋中5类24种兽药残留的高效液相色谱-串联质谱法。样品中的5类兽药(氯霉素类、磺胺类、硝基咪唑类、喹诺酮类和抗病毒类)经1.0%乙酸乙腈溶液提取,氮气吹干,冷冻过夜后,结合QuEChERS净化和正己烷去脂,采用1 mL 0.1%甲酸水-乙腈溶液(v/v,90∶10)复溶;高效液相色谱-串联质谱测定,内标法定量,采用实际样品建立方法的初步应用。结果显示:24种兽药在2.0~200 ng/mL线性关系良好(R2>0.99),该方法的定量限为2μg/kg,平均回收率为62.2%~117.1%,相对标准偏差4.3%~18.9%;实际样品检出的7种目标化合物与标准方法相比的相对标准偏差为1.34%~5.20%。研究表明,建立的检测鸽蛋中多类兽药残留的高通量液相色谱-串联质谱法省去固相萃取步骤,成本较低,灵敏高效,回收率优良、重复性稳定,适用于鸽蛋中多类兽药的快速监测分析。展开更多
为简化前处理过程,降低方法的检出限,进行了题示研究。采集鱼塘底泥样品,混匀、缩分、冷冻干燥、除杂、研磨、过筛后混匀,分取5.00 g,加入10.0μg·L^(-1)^(13)C_(6)-氯硝柳胺水合物标准溶液0.2 m L和含2.0%(体积分数)氨水的乙腈溶...为简化前处理过程,降低方法的检出限,进行了题示研究。采集鱼塘底泥样品,混匀、缩分、冷冻干燥、除杂、研磨、过筛后混匀,分取5.00 g,加入10.0μg·L^(-1)^(13)C_(6)-氯硝柳胺水合物标准溶液0.2 m L和含2.0%(体积分数)氨水的乙腈溶液20 m L,涡旋1 min,超声10 min,离心8 min。上清液于45℃旋蒸至近干,加入2.00 m L 70%(体积分数)乙腈溶液涡旋溶解残留物,再加入200 mg C18涡旋振荡30 s,离心5 min。收集上清液,过0.22μm有机滤膜,滤液采用高效液相色谱-串联质谱法测定。在色谱分析中,以Waters Atiantis^(TM) d C_(18)色谱柱为固定相,水-乙腈体系为流动相进行梯度洗脱;在质谱分析中,以电喷雾离子源负离子(ESI-)模式电离,选择反应监测(SRM)模式检测,内标法定量。结果显示,氯硝柳胺的质量浓度在0.20~50.00μg·L^(-1)内和其定量离子峰面积与同位素内标定量离子峰面积的比值呈线性关系,检出限(3S/N)为0.2μg·kg^(-1)。按照标准加入法进行回收试验,回收率为92.1%~113%,测定值的相对标准偏差(n=6)为1.6%~5.9%。方法用于实际样品的分析,检出的氯硝柳胺的质量分数为0.580~2.18 mg·kg^(-1)。展开更多
基金Project(20776038)supported by the National Natural Science Foundation of China
文摘The chiral separation of phenylsuccinic acid(PSA)was studied by reversed phase high-performance liquid chromatography(RP-HPLC)with cyclodextrins(CDs)as chiral mobile phase additives.The effects of types of CDs,concentration of hydroxypropyl-β-cyclodextrin(HP-β-CD),percentage of organic modifier,pH value and column temperature on enantioselective separation were investigated.The quantification property of the developed RP-HPLC method was examined.The chiral recognition mechanism of PSA was also discussed.The results show that a baseline separation of PSA enantiomers is achieved on a Lichrospher C18 column(4.6 mm(inner diameter)×250 mm,5μm)with HP-β-CD as chiral mobile phase additive.The capacity factors of R-PSA and S-PSA are 3.94 and 4.80,respectively.The separation factor and resolution are respectively 1.22 and 8.03.The mobile phase is a mixture of acetonitrile and deionized water(20-80,volume ratio)containing 10 mmol/L HP-β-CD and 0.05% trifluoroacetic acid(pH 2.5,adjusted with triethylamine)with a flow rate of 1.0 mL/min.The ultraviolet(UV)detector is set at 254 nm.The likely roles are inclusion interaction,induction and hydrogen bonding between HP-β-CD and PSA enantiomers.
基金Sponsored by the Basic Research Funds of Beijing Institute of Technology (20081642007)
文摘The method of reversed-phase high performance liquid chromatography was established for the determination of effective components in OC-CS spray using double wavelength UV detection.The method was utilized under following conditions:a column of Kromasil C18(250 mm × 4.6 mm,5 μm),mobile phase consisting of methanol/water(80 /20) at a flow rate of 0.8 mL/min,column temperature of 25 ℃,and the UV detection at 227 nm and 300 nm.Three key components in OC-CS spray could be distinguished clearly,including o-chlorobenzalmalononitrile(CS),oleoresin capsicum(OC) and dihydrocapsaicin(DC).This method has the advantages of fast,simple and satisfactory linear relationship between UV absorption and concentration.It may be considered to turn into a standard method for detection of related components in the spray.
文摘A high-performance liquid chromatography was describ-ed to measure the concentration of human 3-methylhistidine in urine witho-phthaldialdehyde pre-column derivatization.This assay system resultedin a clear separation of 3-methylhistidine derivative from other derivativ-es in urine within 25 min.Linearity,recovery and coefficients of vari-ation were studied.The method has been successfully applied to routineanalysis for clinical studies and diagnosis.
基金Supported by grants of the National Institute of General Medical Sciences,National Institutes of Health(GM-48364),and the Materials Sciences and Engineering Division of the U.S.Department of Energy(DE-AC02-05CH11231).
文摘Modern porous monoliths have been conceived as a new class of stationary phases for high performance liquid chromatography(HPLC) in classical columns in the early 1990s and later extended to the capillary format.These monolithic materials are prepared using simple processes carried out in an external mold(inorganic monoliths) or within the confines of the column(organic monoliths and all capillary columns).These methods afford macroporous materials with large through-pores that enable applications in a rapid flow-through mode.Since all the mobile phase must flow through the monolith,the convection considerably accelerates mass transport within the monolithic separation medium and improves the separations.As a result,the monolithic columns perform well even at very high flow rates.The applications of monolithic capillary columns are demonstrated on numerous separations in the HPLC mode.
文摘Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine.
基金Project(20235010) support by the NSFC-KOSEF Scientific Cooperation ProgramProject supported by the Program for New Century Talents of University in Henan ProvinceProgram for Backbone Teacher in Henan Province, China
文摘Development of effective chromatographic or electrophoretic separation involves judicious deciding of selection of optimal experimental conditions that can provide an adequate resolution at a reasonable run time for the separation of interested components. Box-Behnken factorial design was effectively applied for the separation optimization of eight structurally related sulfonamides using capillary zone electrophorosis and reverse high performance liquid chromatography. Optimum values for volume ratio of THF to H2O in eluent, column temperature and flow rate of eluent are found as 12 to 88, 35℃ and 1.0 mL/min, respectively. Box-Behnken modified optimization model is extended to separation by capillary electrophoresis (CE). While using CE, a satisfactory separation is achieved with a minimum resolution larger than 1.0 for a separation time less than 10 min.
文摘为建立一种可同时检测鸽蛋中多类兽药残留的高通量液相色谱-串联质谱法,试验采用正己烷去脂,联合QuEChERS净化结合冷冻脂质过滤法,建立检测鸽蛋中5类24种兽药残留的高效液相色谱-串联质谱法。样品中的5类兽药(氯霉素类、磺胺类、硝基咪唑类、喹诺酮类和抗病毒类)经1.0%乙酸乙腈溶液提取,氮气吹干,冷冻过夜后,结合QuEChERS净化和正己烷去脂,采用1 mL 0.1%甲酸水-乙腈溶液(v/v,90∶10)复溶;高效液相色谱-串联质谱测定,内标法定量,采用实际样品建立方法的初步应用。结果显示:24种兽药在2.0~200 ng/mL线性关系良好(R2>0.99),该方法的定量限为2μg/kg,平均回收率为62.2%~117.1%,相对标准偏差4.3%~18.9%;实际样品检出的7种目标化合物与标准方法相比的相对标准偏差为1.34%~5.20%。研究表明,建立的检测鸽蛋中多类兽药残留的高通量液相色谱-串联质谱法省去固相萃取步骤,成本较低,灵敏高效,回收率优良、重复性稳定,适用于鸽蛋中多类兽药的快速监测分析。
文摘为简化前处理过程,降低方法的检出限,进行了题示研究。采集鱼塘底泥样品,混匀、缩分、冷冻干燥、除杂、研磨、过筛后混匀,分取5.00 g,加入10.0μg·L^(-1)^(13)C_(6)-氯硝柳胺水合物标准溶液0.2 m L和含2.0%(体积分数)氨水的乙腈溶液20 m L,涡旋1 min,超声10 min,离心8 min。上清液于45℃旋蒸至近干,加入2.00 m L 70%(体积分数)乙腈溶液涡旋溶解残留物,再加入200 mg C18涡旋振荡30 s,离心5 min。收集上清液,过0.22μm有机滤膜,滤液采用高效液相色谱-串联质谱法测定。在色谱分析中,以Waters Atiantis^(TM) d C_(18)色谱柱为固定相,水-乙腈体系为流动相进行梯度洗脱;在质谱分析中,以电喷雾离子源负离子(ESI-)模式电离,选择反应监测(SRM)模式检测,内标法定量。结果显示,氯硝柳胺的质量浓度在0.20~50.00μg·L^(-1)内和其定量离子峰面积与同位素内标定量离子峰面积的比值呈线性关系,检出限(3S/N)为0.2μg·kg^(-1)。按照标准加入法进行回收试验,回收率为92.1%~113%,测定值的相对标准偏差(n=6)为1.6%~5.9%。方法用于实际样品的分析,检出的氯硝柳胺的质量分数为0.580~2.18 mg·kg^(-1)。