The artificial bee colony(ABC) algorithm is improved to construct a hybrid multi-objective ABC algorithm, called HMOABC, for resolving optimal power flow(OPF) problem by simultaneously optimizing three conflicting obj...The artificial bee colony(ABC) algorithm is improved to construct a hybrid multi-objective ABC algorithm, called HMOABC, for resolving optimal power flow(OPF) problem by simultaneously optimizing three conflicting objectives of OPF, instead of transforming multi-objective functions into a single objective function. The main idea of HMOABC is to extend original ABC algorithm to multi-objective and cooperative mode by combining the Pareto dominance and divide-and-conquer approach. HMOABC is then used in the 30-bus IEEE test system for solving the OPF problem considering the cost, loss, and emission impacts. The simulation results show that the HMOABC is superior to other algorithms in terms of optimization accuracy and computation robustness.展开更多
The axial power flow (APF) magnitude and attenuation distributions of ultrasonic longitudinal guided waves in viscous liquid-filled elastic pipes are investigated. The optimal location, optimal mode and its frequency-...The axial power flow (APF) magnitude and attenuation distributions of ultrasonic longitudinal guided waves in viscous liquid-filled elastic pipes are investigated. The optimal location, optimal mode and its frequency-thickness product (fd) for the test of pipes filled with viscous liquid are chosen according to APF and attenuation distributions. The results show that the APF magnitude distribution is an important parameter in choosing the modes and parameters. A particular mode has weak dispersion in ranges of fd values with large group velocity, while other modes with smaller group velocity in the same fd ranges have stronger dispersion. It has been observed that, within these ranges, the chosen mode has a larger APF on the (pipe’s) wall. Therefore, in the region of fd values where a particular mode has a large group velocity, this mode will be effective to be used in testing elastic pipes filled with viscous liquid. The results obtained from both the APF analysis and attenuation distribution are consistent.展开更多
Two new methods were presented for power flow tracing(PFT).These two methods were compared and the results were discussed in detail.Both methods use the active and reactive power balance equations at each bus in order...Two new methods were presented for power flow tracing(PFT).These two methods were compared and the results were discussed in detail.Both methods use the active and reactive power balance equations at each bus in order to solve the tracing problem.The first method considers the proportional sharing assumption while the second one uses the circuit laws to find the relationship between power inflows and outflows through each line,generator and load connected to each bus of the network.Both methods are able to handle loop flow and loss issues in tracing problem.A formulation is also proposed to find the share of each unit in provision of each load.These methods are applied to find the producer and consumer's shares on the cost of transmission for each line in different case studies.As the results of these studies show,both methods can effectively solve the PFT problem.展开更多
There are many motors in operation or on standby in nuclear power plants,and the startup of group motors will have a great impact on the voltage of the emergency bus.At present,there is no special or inexpensive softw...There are many motors in operation or on standby in nuclear power plants,and the startup of group motors will have a great impact on the voltage of the emergency bus.At present,there is no special or inexpensive software to solve this problem,and the experience of engineers is not accurate enough.Therefore,this paper developed a method and system for the startup calculation of group motors in nuclear power plants and proposed an automatic generation method of circuit topology in nuclear power plants.Each component in the topology was given its unique number,and the component class could be constructed according to its type and upper and lower connections.The subordination and topology relationship of switches,buses,and motors could be quickly generated by the program according to the component class,and the simplified direct power flow algorithm was used to calculate the power flow for the startup of group motors according to the above relationship.Then,whether the bus voltage is in the safe range and whether the voltage exceeds the limit during the startup of the group motor could be judged.The practical example was used to verify the effectiveness of the method.Compared with other professional software,the method has high efficiency and low cost.展开更多
电力系统分析综合程序PSASP(power system analysis software package)和PowerFactory是目前广泛采用的电力系统分析软件,也是重庆大学电气工程学院"电力系统稳态分析"课程的实验教学工具软件。然而学生在实验中发现,对于同...电力系统分析综合程序PSASP(power system analysis software package)和PowerFactory是目前广泛采用的电力系统分析软件,也是重庆大学电气工程学院"电力系统稳态分析"课程的实验教学工具软件。然而学生在实验中发现,对于同一算例,两个软件的潮流计算结果并不一致。分析表明,结果不一致的原因在于两个软件所用变压器模型存在差异。为此,本文从变压器参数计算方法、对励磁支路的处理等方面,对PSASP和PowerFactory的双绕组/三绕组变压器模型进行对比分析,并提出使两个软件潮流结果差异尽可能小的参数及控制选项设置方法。本文用两个简单算例验证了对比分析结果的有效性。展开更多
基金Projects(61105067,61174164)supported by the National Natural Science Foundation of China
文摘The artificial bee colony(ABC) algorithm is improved to construct a hybrid multi-objective ABC algorithm, called HMOABC, for resolving optimal power flow(OPF) problem by simultaneously optimizing three conflicting objectives of OPF, instead of transforming multi-objective functions into a single objective function. The main idea of HMOABC is to extend original ABC algorithm to multi-objective and cooperative mode by combining the Pareto dominance and divide-and-conquer approach. HMOABC is then used in the 30-bus IEEE test system for solving the OPF problem considering the cost, loss, and emission impacts. The simulation results show that the HMOABC is superior to other algorithms in terms of optimization accuracy and computation robustness.
文摘The axial power flow (APF) magnitude and attenuation distributions of ultrasonic longitudinal guided waves in viscous liquid-filled elastic pipes are investigated. The optimal location, optimal mode and its frequency-thickness product (fd) for the test of pipes filled with viscous liquid are chosen according to APF and attenuation distributions. The results show that the APF magnitude distribution is an important parameter in choosing the modes and parameters. A particular mode has weak dispersion in ranges of fd values with large group velocity, while other modes with smaller group velocity in the same fd ranges have stronger dispersion. It has been observed that, within these ranges, the chosen mode has a larger APF on the (pipe’s) wall. Therefore, in the region of fd values where a particular mode has a large group velocity, this mode will be effective to be used in testing elastic pipes filled with viscous liquid. The results obtained from both the APF analysis and attenuation distribution are consistent.
文摘Two new methods were presented for power flow tracing(PFT).These two methods were compared and the results were discussed in detail.Both methods use the active and reactive power balance equations at each bus in order to solve the tracing problem.The first method considers the proportional sharing assumption while the second one uses the circuit laws to find the relationship between power inflows and outflows through each line,generator and load connected to each bus of the network.Both methods are able to handle loop flow and loss issues in tracing problem.A formulation is also proposed to find the share of each unit in provision of each load.These methods are applied to find the producer and consumer's shares on the cost of transmission for each line in different case studies.As the results of these studies show,both methods can effectively solve the PFT problem.
基金Key Project of National Natural Science Foundation of China(52237008)Beijing Municipal Education Commission Research Program Funding Project(KM202111232022)。
文摘There are many motors in operation or on standby in nuclear power plants,and the startup of group motors will have a great impact on the voltage of the emergency bus.At present,there is no special or inexpensive software to solve this problem,and the experience of engineers is not accurate enough.Therefore,this paper developed a method and system for the startup calculation of group motors in nuclear power plants and proposed an automatic generation method of circuit topology in nuclear power plants.Each component in the topology was given its unique number,and the component class could be constructed according to its type and upper and lower connections.The subordination and topology relationship of switches,buses,and motors could be quickly generated by the program according to the component class,and the simplified direct power flow algorithm was used to calculate the power flow for the startup of group motors according to the above relationship.Then,whether the bus voltage is in the safe range and whether the voltage exceeds the limit during the startup of the group motor could be judged.The practical example was used to verify the effectiveness of the method.Compared with other professional software,the method has high efficiency and low cost.
文摘电力系统分析综合程序PSASP(power system analysis software package)和PowerFactory是目前广泛采用的电力系统分析软件,也是重庆大学电气工程学院"电力系统稳态分析"课程的实验教学工具软件。然而学生在实验中发现,对于同一算例,两个软件的潮流计算结果并不一致。分析表明,结果不一致的原因在于两个软件所用变压器模型存在差异。为此,本文从变压器参数计算方法、对励磁支路的处理等方面,对PSASP和PowerFactory的双绕组/三绕组变压器模型进行对比分析,并提出使两个软件潮流结果差异尽可能小的参数及控制选项设置方法。本文用两个简单算例验证了对比分析结果的有效性。