期刊文献+
共找到13,645篇文章
< 1 2 250 >
每页显示 20 50 100
Field system-level calibration method for accelerometer considering nonlinear coefficients
1
作者 WU Haotian YU Ruihang +2 位作者 CAO Juliang MA Caixia YANG Bainan 《Journal of Systems Engineering and Electronics》 2025年第3期814-824,共11页
In order to get rid of the dependence on high-precision centrifuges in accelerometer nonlinear coefficients calibration,this paper proposes a system-level calibration method for field condition.Firstly,a 42-dimension ... In order to get rid of the dependence on high-precision centrifuges in accelerometer nonlinear coefficients calibration,this paper proposes a system-level calibration method for field condition.Firstly,a 42-dimension Kalman filter is constructed to reduce impact brought by turntable.Then,a biaxial rotation path is designed based on the accelerometer output model,including orthogonal 22 positions and tilt 12 positions,which enhances gravity excitation on nonlinear coefficients of accelerometer.Finally,sampling is carried out for calibration and further experiments.The results of static inertial navigation experiments lasting 4000 s show that compared with the traditional method,the proposed method reduces the position error by about 390 m. 展开更多
关键词 ACCELEROMETER nonlinear coefficient system-level calibration rotation path
在线阅读 下载PDF
Far-field calibration of automotive millimeter wave radar via near-field implementation
2
作者 SUN Jinghu LIU Jiahuan +3 位作者 WEI Wenqiang YU Xianxiang CUI Guolong ZHANG Xiuyin 《Journal of Systems Engineering and Electronics》 2025年第3期694-700,共7页
To enhance direction of arrival(DOA)estimation accuracy,this paper proposes a low-cost method for calibrating farfield steering vectors of large aperture millimeter wave radar(mmWR).To this end,we first derive the ste... To enhance direction of arrival(DOA)estimation accuracy,this paper proposes a low-cost method for calibrating farfield steering vectors of large aperture millimeter wave radar(mmWR).To this end,we first derive the steering vectors with amplitude and phase errors,assuming that mmWR works in the time-sharing mode.Then,approximate relationship between the near-field calibration steering vector and the far-field calibration steering vector is analyzed,which is used to accomplish the mapping between the two of them.Finally,simulation results verify that the proposed method can effectively improve the angle measurement accuracy of mmWR with existing amplitude and phase errors. 展开更多
关键词 automotive millimeter wave radar far-field steering vector calibration near-field steering vector calibration direction of arrival(DOA)estimation low cost
在线阅读 下载PDF
Kinematic calibration under the expectation maximization framework for exoskeletal inertial motion capture system
3
作者 QIN Weiwei GUO Wenxin +2 位作者 HU Chen LIU Gang SONG Tainian 《Journal of Systems Engineering and Electronics》 SCIE CSCD 2024年第3期769-779,共11页
This study presents a kinematic calibration method for exoskeletal inertial motion capture (EI-MoCap) system with considering the random colored noise such as gyroscopic drift.In this method, the geometric parameters ... This study presents a kinematic calibration method for exoskeletal inertial motion capture (EI-MoCap) system with considering the random colored noise such as gyroscopic drift.In this method, the geometric parameters are calibrated by the traditional calibration method at first. Then, in order to calibrate the parameters affected by the random colored noise, the expectation maximization (EM) algorithm is introduced. Through the use of geometric parameters calibrated by the traditional calibration method, the iterations under the EM framework are decreased and the efficiency of the proposed method on embedded system is improved. The performance of the proposed kinematic calibration method is compared to the traditional calibration method. Furthermore, the feasibility of the proposed method is verified on the EI-MoCap system. The simulation and experiment demonstrate that the motion capture precision is significantly improved by 16.79%and 7.16%respectively in comparison to the traditional calibration method. 展开更多
关键词 human motion capture kinematic calibration EXOSKELETON gyroscopic drift expectation maximization(EM)
在线阅读 下载PDF
平行机的实时到达on-line算法下界的改进 被引量:1
4
作者 陈仕平 姚恩瑜 《高校应用数学学报(A辑)》 CSCD 北大核心 1999年第3期315-318,共4页
本文考虑了平行机实时到达的在线问题.模型中,工件是陆续到达的,工件的个数、到达时间是事先未知的,而且只有当工件到达,才知其加工时间,目标是使所有工件都加工完的时间达到最小.Chen与Vestjens(1996年)证明... 本文考虑了平行机实时到达的在线问题.模型中,工件是陆续到达的,工件的个数、到达时间是事先未知的,而且只有当工件到达,才知其加工时间,目标是使所有工件都加工完的时间达到最小.Chen与Vestjens(1996年)证明了该在线问题不存在性能比小于1.3473的on-line算法.本文将此界改进为(5-5)/2. 展开更多
关键词 排序 on-line算法 平行机 组合最优化 实时到达
在线阅读 下载PDF
On-line置换液与生理盐水在血液透析滤过回血中的应用效果比较 被引量:5
5
作者 祝喜鹰 刘金凤 肖静 《护理研究(上旬版)》 2014年第7期2370-2372,共3页
[目的]探讨On-line置换液与生理盐水在血液透析滤过(HDF)病人回血中的应用效果,以期为临床护理工作提供理论依据。[方法]选取30例规律HDF病人为研究对象,采用自身对照方法,每例病人每周依次采用On-line置换液和生理盐水回血,比较回血过... [目的]探讨On-line置换液与生理盐水在血液透析滤过(HDF)病人回血中的应用效果,以期为临床护理工作提供理论依据。[方法]选取30例规律HDF病人为研究对象,采用自身对照方法,每例病人每周依次采用On-line置换液和生理盐水回血,比较回血过程中残余血量、静脉壶液体温度、护士的工作量及经济效益。[结果]采用On-line置换液回血法残余血量及回血后静脉壶温度分别为(1.89±0.91)mL,(33.36±0.15)℃,而采用生理盐水法为(2.88±0.23)mL、(27.13±0.14)℃,差异均有统计学意义(P<0.01);而透析器凝血状况比较差异无统计学意义(P=0.08);采用On-line置换液回血时护士工作量减少,回血液体成本降低。[结论]应用接近生理温度的On-line置换液回血能稀释血液、降低血液黏稠度,减少血路管残余血量,增加病人舒适感,提高工作效率。 展开更多
关键词 联机血液透析滤过 液体回血 on-line置换液 生理盐水 残余血量 工作量
在线阅读 下载PDF
Multi-camera calibration method based on minimizing the difference of reprojection error vectors 被引量:6
6
作者 HUO Ju LI Yunhui YANG Ming 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2018年第4期844-853,共10页
In order to achieve a high precision in three-dimensional(3D) multi-camera measurement system, an efficient multi-cameracalibration method is proposed. A stitching method of large scalecalibration targets is deduced... In order to achieve a high precision in three-dimensional(3D) multi-camera measurement system, an efficient multi-cameracalibration method is proposed. A stitching method of large scalecalibration targets is deduced, and a fundamental of multi-cameracalibration based on the large scale calibration target is provided.To avoid the shortcomings of the method, the vector differencesof reprojection error with the presence of the constraint conditionof the constant rigid body transformation is modelled, and mini-mized by the Levenberg-Marquardt (LM) method. Results of thesimulation and observation data calibration experiment show thatthe accuracy of the system calibrated by the proposed methodreaches 2 mm when measuring distance section of 20 000 mmand scale section of 7 000 mm × 7 000 mm. Consequently, theproposed method of multi-camera calibration performs better thanthe fundamental in stability. This technique offers a more uniformerror distribution for measuring large scale space. 展开更多
关键词 vision measurement multi-camera calibration field stitching vector error
在线阅读 下载PDF
Solution for polarimetric radar cross section measurement and calibration 被引量:7
7
作者 Peikang Huang Chao Ning +2 位作者 Xiaojian Xu Hua Yan Zhaoguo Hou 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2014年第2期211-216,共6页
The exact radar cross-section (RCS) measurement is difficult when the scattering of targets is low. Ful polarimetric cali-bration is one technique that offers the potential for improving the accuracy of RCS measurem... The exact radar cross-section (RCS) measurement is difficult when the scattering of targets is low. Ful polarimetric cali-bration is one technique that offers the potential for improving the accuracy of RCS measurements. There are numerous polarimetric calibration algorithms. Some complex expressions in these algo-rithms cannot be easily used in an engineering practice. A radar polarimetric coefficients matrix (RPCM) with a simpler expression is presented for the monostatic radar polarization scattering matrix (PSM) measurement. Using a rhombic dihedral corner reflector and a metal ic sphere, the RPCM can be obtained by solving a set of equations, which can be used to find the true PSM for any target. An example for the PSM of a metal ic dish shows that the proposed method obviously improves the accuracy of cross-polarized RCS measurements. 展开更多
关键词 radar cross section (RCS) polarization scattering ma-trix (PSM) polarimetric calibration polarimetry.
在线阅读 下载PDF
Calibration method of phase distortions for cross polarization channel of instantaneous polarization radar system 被引量:7
8
作者 Huanyao Dai Yuliang Chang Dahai Dai Yongzhen Li XuesongWang 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2010年第2期211-218,共8页
A novel polarimetric calibration method for new target property measurement radar system is presented. Its applica- tion in the real radar system is also discussed. The analysis indicates that instantaneous polarizati... A novel polarimetric calibration method for new target property measurement radar system is presented. Its applica- tion in the real radar system is also discussed. The analysis indicates that instantaneous polarization radar ([PR) has inherent cross-polarization measurement error. The proposed method can effectively eliminate this error, and thus enhance the polarization scattering matrix (PSM) measurement precision. The phase error caused by digital receiver's direct IF sampling and mixing of two orthogonal polarization channels can be removed. Consequently, the inherent error of target polarization scattering measurement of the instantaneous polarization radar system is well revised. It has good reference value for further ploarimetric calibration and high practical application prospect. 展开更多
关键词 instantaneous polarization radar target scattering ma- trix (PSM) polarization measurement polarimetric calibration.
在线阅读 下载PDF
Research of optimizing the microwave wide band blackbody calibration target 被引量:2
9
作者 Nian Feng Yang Yujie Wang Wei 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2009年第1期6-12,共7页
The blackbody calibration targets applied for microwave radiometer's prelaunch calibration are optimized with its electromagnetic and thermal characteristics. Based on the method of emissivity optimization with radar... The blackbody calibration targets applied for microwave radiometer's prelaunch calibration are optimized with its electromagnetic and thermal characteristics. Based on the method of emissivity optimization with radar cross section (RCS) simulation and the method of subgrid finite difference time domain (FDTD), the following design rules are summarized: that the round wedge is better than the square one, the best ratio from height to bottom radius is 4:1, for wide band calibration, the multilayer absorbing material coating is efficient to increase the emissivity, and the gradual thickness absorbing material coating is helpful to guarantee the uniform distribution of surface temperature even as it keeps a higher emissivity. Finally following the above conclusions, a new type of blackbody calibration target with the cellular array is preferred to improve the uniformity of polarization, which will increase the performance of the calibration targets further. 展开更多
关键词 BLACKBODY calibration target microwave radiometer remote sensing.
在线阅读 下载PDF
Method for array gain and phase uncertainties calibration based on ISM and ESPRIT 被引量:11
10
作者 Liao Bin Liao Guisheng 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2009年第2期223-228,共6页
A new method for array calibration of array gain and phase uncertainties, which severely degrade the performance of spatial spectrum estimation, is presented. The method is based on the idea of the instrumental sensor... A new method for array calibration of array gain and phase uncertainties, which severely degrade the performance of spatial spectrum estimation, is presented. The method is based on the idea of the instrumental sensors method (ISM), two well-calibrated sensors are added into the original array. By applying the principle of estimation of signal parameters via rotational invariance techniques (ESPRIT), the direction-of-arrivals (DOAs) and uncertainties can be estimated simultaneously through eigen-decomposition. Compared with the conventional ones, this new method has less computational complexity while has higher estimation precision, what's more, it can overcome the problem of ambiguity. Both theoretical analysis and computer simulations show the effectiveness of the proposed method. 展开更多
关键词 array calibration array gain and phase uncertainties direction of arrival instrumental sensors method estimation of signal parameters via rotationaJ invariance techniques.
在线阅读 下载PDF
Model calibration concerning risk coefficients of driving safety field model 被引量:6
11
作者 LI Yang WANG Jian-qiang WU Jian 《Journal of Central South University》 SCIE EI CAS CSCD 2017年第6期1494-1502,共9页
Driving safety field(DSF) model has been proposed to represent comprehensive driving risk formed by interactions of driver-vehicle-road in mixed traffic environment. In this work, we establish an optimization model ba... Driving safety field(DSF) model has been proposed to represent comprehensive driving risk formed by interactions of driver-vehicle-road in mixed traffic environment. In this work, we establish an optimization model based on grey relation degree analysis to calibrate risk coefficients of DSF model. To solve the optimum solution, a genetic algorithm is employed. Finally, the DSF model is verified through a real-world driving experiment. Results show that the DSF model is consistent with driver's hazard perception and more sensitive than TTC. Moreover, the proposed DSF model offers a novel way for criticality assessment and decision-making of advanced driver assistance systems and intelligent connected vehicles. 展开更多
关键词 intelligent CONNECTED vehicles advanced DRIVER ASSISTANCE systems (ADAS) driving risk assessment driving safety field (DSF) model parameter calibration GREY relation DEGREE
在线阅读 下载PDF
Self-adaptive PID controller of microwave drying rotary device tuning on-line by genetic algorithms 被引量:6
12
作者 杨彪 梁贵安 +5 位作者 彭金辉 郭胜惠 李玮 张世敏 李英伟 白松 《Journal of Central South University》 SCIE EI CAS 2013年第10期2685-2692,共8页
The control design, based on self-adaptive PID with genetic algorithms(GA) tuning on-line was investigated, for the temperature control of industrial microwave drying rotary device with the multi-layer(IMDRDWM) and wi... The control design, based on self-adaptive PID with genetic algorithms(GA) tuning on-line was investigated, for the temperature control of industrial microwave drying rotary device with the multi-layer(IMDRDWM) and with multivariable nonlinear interaction of microwave and materials. The conventional PID control strategy incorporated with optimization GA was put forward to maintain the optimum drying temperature in order to keep the moisture content below 1%, whose adaptation ability included the cost function of optimization GA according to the output change. Simulations on five different industrial process models and practical temperature process control system for selenium-enriched slag drying intensively by using IMDRDWM were carried out systematically, indicating the reliability and effectiveness of control design. The parameters of proposed control design are all on-line implemented without iterative predictive calculations, and the closed-loop system stability is guaranteed, which makes the developed scheme simpler in its synthesis and application, providing the practical guidelines for the control implementation and the parameter design. 展开更多
关键词 industrial microwave DRYING ROTARY device SELF-ADAPTIVE PID controller genetic algorithm on-line tuning SELENIUM-ENRICHED SLAG
在线阅读 下载PDF
Recent progress on space-borne microwave sounder pre-launch calibration technologies in China 被引量:1
13
作者 Nian Feng Yang Yujie +2 位作者 Chen Yunmei Xu Dezhong Wang Wei 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2008年第4期643-651,658,共10页
The development processes and the application achievements of space-borne microwave sounder pre-launch calibration technologies in China are introduced briefly. Then, the general project plan for pre-launch calibratio... The development processes and the application achievements of space-borne microwave sounder pre-launch calibration technologies in China are introduced briefly. Then, the general project plan for pre-launch calibration, the latest research achievements on the optimization and development of the microwave wide band calibration targets, emissivity measurement technologies and the system level uncertainty analysis of the laboratory, and the thermal/vacuum microwave sounder calibration system for "FY-3" meteorological satellite are reported, respectively. Finally, the key technological problems of the calibration technologies under researching are analyzed predictively. 展开更多
关键词 microwave sounder calibration UNCERTAINTY remote sensing
在线阅读 下载PDF
Reagent optimization for on-line simultaneous polarographic determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in the presence of anextremely large excess of Zn^(2+) 被引量:4
14
作者 WANG Guo-wei YANG Chun-hua +2 位作者 ZHU Hong-qiu LI Yong-gang GUI Wei-hua 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第9期2199-2204,共6页
Reagents are optimized for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in zinc sulfate solution, which contains an extremely large excess of Zn^(2+). First, the reagents and their d... Reagents are optimized for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in zinc sulfate solution, which contains an extremely large excess of Zn^(2+). First, the reagents and their doses for the experiment are selected according to the characteristics of the zinc sulfate solution. Then, the reagent doses are optimized by analyzing the influence of reagent dose on the polarographic parameters(i.e. half-wave potential E_(1/2) and limiting diffusion current I_p). Finally, the optimization results are verified by simultaneously determining trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in the presence of an extremely large excess of Zn^(2+). The determination results indicate that the optimized reagents exhibit wide linearity, low detection limits, high accuracy and good precision for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in the presence of an extremely large excess of Zn^(2+). 展开更多
关键词 on-line simultaneous determination trace polymetallic ions reagent optimization high concentration ratio
在线阅读 下载PDF
Optimal measurement configurations for kinematic calibration of six-DOF serial robot 被引量:4
15
作者 黎田 孙奎 +1 位作者 谢宗武 刘宏 《Journal of Central South University》 SCIE EI CAS 2011年第3期618-626,共9页
An optimal measurement pose number searching method was designed to improve the pose selection method.Several optimal robot measurement configurations were added to an initial pre-selected optimal configuration set to... An optimal measurement pose number searching method was designed to improve the pose selection method.Several optimal robot measurement configurations were added to an initial pre-selected optimal configuration set to establish a new configuration set for robot calibration one by one.The root mean squares (RMS) of the errors of each end-effector poses after being calibrated by these configuration sets were calculated.The optimal number of the configuration set corresponding to the least RMS of pose error was then obtained.Calibration based on those poses selected by this algorithm can get higher end-effector accuracy,meanwhile consumes less time.An optimal pose set including optimal 25 measurement configurations is found during the simulation.Tracking errors after calibration by using these poses are 1.54,1.61 and 0.86 mm,and better than those before calibration which are 7.79,7.62 and 8.29 mm,even better than those calibrated by the random method which are 2.22,2.35 and 1.69 mm in directions X,Y and Z,respectively. 展开更多
关键词 serial robot pose selection pose number kinematic calibration observability index
在线阅读 下载PDF
Weighted joint calibration for interferometric SAR 被引量:1
16
作者 Yongfei Mao Maosheng Xiang +1 位作者 Yunzhong Han Wenjun Gao 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2013年第5期761-771,共11页
Calibration is a processing procedure for across-track interferometric synthetic aperture radar (InSAR) to achieve an accurate three-dimensional location. A calibration technique, called weighted joint calibration, ... Calibration is a processing procedure for across-track interferometric synthetic aperture radar (InSAR) to achieve an accurate three-dimensional location. A calibration technique, called weighted joint calibration, for the generation of wide-area geocoded digital elevation models (DEMs) is proposed. It cali- brates multiple InSAR scenes simultaneously, and allows reducing the number of required ground control points (GCPs) by using tie points (TPs). This approach may ensure the continuity of three- dimensional location among adjacent scenes, which is necessary for mosaic and fusion of data coming from different scenes. In addition, it introduces weights to calibration to discriminate GCPs and TPs with different coherences and locations. This paper presents the principles and methodology of this weighted joint calibration technique and illustrates its successful application in airborne In- SAR data. 展开更多
关键词 calibration synthetic aperture radar (SAR) interfe- rometry radar data processing.
在线阅读 下载PDF
A smart calibration model on track's pressure-sinkage characteristic of a tracked vehicle moving on soft seabed sediments 被引量:2
17
作者 曾谊晖 周育才 +1 位作者 刘道才 左青松 《Journal of Central South University》 SCIE EI CAS 2013年第4期911-917,共7页
The bentonite-water mixture was selected as the substitute of seabed sediments according to the in-situ measurement data of sediments 15-20 cm deep in China's ocean poly-metallic mining contract area and the soft ... The bentonite-water mixture was selected as the substitute of seabed sediments according to the in-situ measurement data of sediments 15-20 cm deep in China's ocean poly-metallic mining contract area and the soft seabed sediments could be simulated with certain proportion of the bentonite and water; besides, based on the theory on the interaction between the vehicle and ground and referenced to Bekker's apparatus and related experimental methods, a scenario on the experimental system of the pressure-sinkage characteristics of interaction between the track of tracked vehicle and soft seabed sediments was designed. The pressure-sinkage experiments were performed with different dimensions of penetration plates. The "pressure-sinkage" model based on Bekker's formula and correlation parameters were obtained to describe the corresponding characteristics of the seabed sediments and a smart calibration model on the pressure-sinkage characteristic of the track was established based on the function chain neural network, which could provide boundary loading conditions for simulation analysis of the tracked vehicle moving on the seabed. 展开更多
关键词 tracked vehicle TRACK seabed sediments pressure-sinkage characteristic smart calibration
在线阅读 下载PDF
An iterative calibration method for nonlinear coefficients of marine triaxial accelerometers 被引量:2
18
作者 杨杰 吴文启 +1 位作者 武元新 练军想 《Journal of Central South University》 SCIE EI CAS 2013年第11期3103-3115,共13页
Single-axis rotation technique is often used in the marine laser inertial navigation system so as to modulate the constant biases of non-axial gyroscopes and accelerometers to attain better navigation performance.Howe... Single-axis rotation technique is often used in the marine laser inertial navigation system so as to modulate the constant biases of non-axial gyroscopes and accelerometers to attain better navigation performance.However,two significant accelerometer nonlinear errors need to be attacked to improve the modulation effect.Firstly,the asymmetry scale factor inaccuracy enlarges the errors of frequent zero-cross oscillating specific force measured by non-axial accelerometers.Secondly,the traditional linear model of accelerometers can hardly measure the continued or intermittent acceleration accurately.These two nonlinear errors degrade the high-precision specific force measurement and the calibration of nonlinear coefficients because triaxial accelerometers is urgent for the marine navigation.Based on the digital signal sampling property,the square coefficients and cross-coupling coefficients of accelerometers are considered.Meanwhile,the asymmetry scale factors are considered in the I-F conversion unit.Thus,a nonlinear model of specific force measurement is established compared to the linear model.Based on the three-axis turntable,the triaxial gyroscopes are utilized to measure the specific force observation for triaxial accelerometers.Considering the nonlinear combination,the standard calibration parameters and asymmetry factors are separately estimated by a two-step iterative identification procedure.Besides,an efficient specific force calculation model is approximately derived to reduce the real-time computation cost.Simulation results illustrate the sufficient estimation accuracy of nonlinear coefficients.The experiments demonstrate that the nonlinear model shows much higher accuracy than the linear model in both the gravimetry and sway navigation validations. 展开更多
关键词 ship navigation single-axis rotation inertial system laser gyroscopes quartz accelerometers nonlinear calibration
在线阅读 下载PDF
SAGE-based algorithm for DOA estimation and array calibration in the presence of sensor location errors 被引量:1
19
作者 XIONG Kunlai LIU Zhangmeng WANG Pei 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2019年第6期1074-1080,共7页
The direction of arrival(DOA) estimation problem in the presence of sensor location errors is studied and an algorithm based on space alternating generalized expectation-maximization(SAGE) is presented. First, the nar... The direction of arrival(DOA) estimation problem in the presence of sensor location errors is studied and an algorithm based on space alternating generalized expectation-maximization(SAGE) is presented. First, the narrowband case is considered.Based on the small perturbation assumption, this paper proposes an augmentation scheme so as to estimate DOA and perturbation parameters. The E-step and M-step of the SAGE algorithm in this case are derived. Then, the algorithm is extended to the wideband case. The wideband SAGE algorithm is derived in frequency domain by jointing all frequency bins. Simulation results show that the algorithm achieves good convergence and high parameter estimation precision. 展开更多
关键词 direction of arrival(DOA) array calibration space alternating generalized expectation-maximization(SAGE) wide band signal.
在线阅读 下载PDF
Novel camera calibration method based on invariance of collinear points and pole-polar constraint 被引量:2
20
作者 WEI Liang ZHANG Guiyang +1 位作者 HUO Ju XUE Muyao 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2023年第3期744-753,共10页
To address the eccentric error of circular marks in camera calibration,a circle location method based on the invariance of collinear points and pole–polar constraint is proposed in this paper.Firstly,the centers of t... To address the eccentric error of circular marks in camera calibration,a circle location method based on the invariance of collinear points and pole–polar constraint is proposed in this paper.Firstly,the centers of the ellipses are extracted,and the real concentric circle center projection equation is established by exploiting the cross ratio invariance of the collinear points.Subsequently,since the infinite lines passing through the centers of the marks are parallel,the other center projection coordinates are expressed as the solution problem of linear equations.The problem of projection deviation caused by using the center of the ellipse as the real circle center projection is addressed,and the results are utilized as the true image points to achieve the high precision camera calibration.As demonstrated by the simulations and practical experiments,the proposed method performs a better location and calibration performance by achieving the actual center projection of circular marks.The relevant results confirm the precision and robustness of the proposed approach. 展开更多
关键词 camera calibration cross ratio invariance infinite lines eccentricity error compensate
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部