With different structural forms of ventilation pipes have various attenuation effects on incident shock waves while meeting ventilation requirements.The attenuation mechanism and the propagation law of shock waves in ...With different structural forms of ventilation pipes have various attenuation effects on incident shock waves while meeting ventilation requirements.The attenuation mechanism and the propagation law of shock waves in ventilation pipes of different structures are investigated by experiments and numerical simulations.Furthermore,for the same structure,the effects of peak pressure and positive pressure time on the attenuation rate are discussed.It is found that the attenuation rate increases with the incident shock wave pressure,and the shock wave attenuation rate tends to reach its limiting value k for the same structure and reasonably short positive pressure time.Under the same conditions,the attenuation rate is calculated using the pressure of the shock wave as follows:diffusion chamber pipe,branch pipe and selfconsumption pipe;the attenuation rate per unit volume is calculated as follows:self-consumption pipe,branch pipe and diffusion chamber pipe.In addition,an easy method is provided to calculate the attenuation rate of the shock wave in single and multi-stage ventilation pipes.Corresponding parameters are provided for various structures,and the margin of error between the formulae and experimental results is within 10%,which is significant for engineering applications.展开更多
The breakage and bending of ducts result in a difficulty to cope with ventilation issues in bidirectional excavation tunnels with a long inclined shaft using a single ventilation method based on ducts.To discuss the h...The breakage and bending of ducts result in a difficulty to cope with ventilation issues in bidirectional excavation tunnels with a long inclined shaft using a single ventilation method based on ducts.To discuss the hybrid ventilation system applied in bidirectional excavation tunnels with a long inclined shaft,this study has established a full-scale computational fluid dynamics model based on field tests,the Poly-Hexcore method,and the sliding mesh technique.The distribution of wind speed,temperature field,and CO in the tunnel are taken as indices to compare the ventilation efficiency of three ventilation systems(duct,duct-ventilation shaft,duct–ventilated shaft-axial fan).The results show that the hybrid ventilation scheme based on duct-ventilation shaft–axial fan performs the best among the three ventilation systems.Compared to the duct,the wind speed and cooling rate in the tunnel are enhanced by 7.5%–30.6%and 14.1%–17.7%,respectively,for the duct-vent shaft-axial fan condition,and the volume fractions of CO are reduced by 26.9%–73.9%.This contributes to the effective design of combined ventilation for bidirectional excavation tunnels with an inclined shaft,ultimately improving the air quality within the tunnel.展开更多
Because of the multiple problems on high energy consumption and unbalanced thermal comfort caused by the traditional ventilation system,a new concept of ventilation-stratum ventilation has been proposed,which sends th...Because of the multiple problems on high energy consumption and unbalanced thermal comfort caused by the traditional ventilation system,a new concept of ventilation-stratum ventilation has been proposed,which sends the fresh air to the breathing zone directly.In this paper,the local air distributions of the displacement ventilation and the stratum ventilation in a model office were measured.The air ages in the breathing zone for the displacement ventilation and stratum ventilation were compared with the tracer gas concentration decay method.The decay curves of tracer gas concentration for these two ventilation systems in the breathing zone were obtained,and the air ages were calculated.The experimental results show that the stratum ventilation system can offer lower air age for four mechanically ventilated cases in the breathing zone,and it can also provide better thermal comfort,which renews the air of breathing zone more quickly and reduces the energy consumption in some degree.The experimental investigation provides a theoretical basis for the application of stratum ventilation system.展开更多
In order to control the dust pollution produced by air leg rock drill in the trolley area during the excavation of long-distance single ended tunnel,the full-scale physical model of working face was established by usi...In order to control the dust pollution produced by air leg rock drill in the trolley area during the excavation of long-distance single ended tunnel,the full-scale physical model of working face was established by using FLUENT software,and the numerical simulation analysis of tunnel drilling ventilation and dust removal parameters was carried out.The results show that it is difficult to control the dust pollution of the face by conventional ventilation,and the drilling dust is distributed in the range of 10 m from the face;after the introduction of the long pressure and short suction ventilation scheme,when the ratio of compressed air volume to exhaust air volume is 0.72,the height of the pressure fan is 2.5 m,the distance between the pressure fan and the palm face is 20 m,and the exhaust fan is 12 m away from the palm,the dust concentration control efficiency of the working face is increased by about 60%.Therefore,in the similar long-distance single head tunnel construction,it is appropriate to adopt the dust removal method of long-distance short suction and exhaust fan to ensure the working environment.展开更多
The current popular methods for decision making and project optimisation in mine ventilation contain a number of deficiencies as they are solely based on either subjective knowledge or objective information.This paper...The current popular methods for decision making and project optimisation in mine ventilation contain a number of deficiencies as they are solely based on either subjective knowledge or objective information.This paper presents a new approach to rank the alternatives by G1-coefficient of variation method.The focus of this approach is the use of the combination weighing,which is able to compensate for the deficiencies in the method of evaluation index single weighing.In the case study,an appropriate evaluation index system was established to determine the evaluation value of each ventilation mode.Then the proposed approach was used to select the best development face ventilation mode.The result shows that the proposed approach is able to rank the alternative development face ventilation mode reasonably,the combination weighing method had the advantages of both subjective and objective weighing methods in that it took into consideration of both the experience and wisdom of experts,and the new changes in objective conditions.This approach provides a more reasonable and reliable procedure to analyse and evaluate different ventilation modes.展开更多
The 1/15 reduced-scale experiments using Froude scaling were designed to study the effect on the smoke control efficiency for subway tunnel fires with natural ventilation mode.The propane gas fires with heat release r...The 1/15 reduced-scale experiments using Froude scaling were designed to study the effect on the smoke control efficiency for subway tunnel fires with natural ventilation mode.The propane gas fires with heat release rate 11.48 kW was used,which corresponds to the heat release rate 10 MW in the full-scale tunnel.The temperature distributions under the ceiling were measured by K-type thermocouples to investigate smoke movement,and the velocity of smoke in shafts was measured by hot-wire anemometer to obtain the smoke extract amount of ventilation shafts.The results show that the smoke temperature under the ceiling varies with the longitudinal different distance from fire source.The results also show that the smoke temperature distributions and the smoke control efficiency in tunnel vary with the space between ventilation shafts and vary with the area and the height of ventilation shaft.展开更多
Ventilation system is significant in underground metal mine of alpine region.Reasonable evaluation of ventilation effectiveness will lead to a practical improvement for the maintenance and management of ventilation sy...Ventilation system is significant in underground metal mine of alpine region.Reasonable evaluation of ventilation effectiveness will lead to a practical improvement for the maintenance and management of ventilation system.However,it is difficult to make an effective evaluation of ventilation system due to the lack of classification criteria with respect to underground metal mine in alpine region.This paper proposes a novel evaluation method called the cloud model-clustering analysis(CMCA).Cloud model(CM)is utilized to process collected data of ventilation system,and they are converted into cloud descriptors by CM.Cloud similarity(CS)based Euclidean distance(ED)is proposed to make clustering analysis of assessed samples.Then the classification of assessed samples will be identified by clustering analysis results.A case study is developed based on CMCA.Evaluation results show that ventilation effectiveness can be well classified.Moreover,CM is used alone to make comparison of evaluation results obtained by CMCA.Then the availability and validity of CMCA is verified.Meanwhile,difference of CS based ED and classical ED is analyzed.Two new clustering analysis methods are introduced to make comparison with CMCA.Then the ability of proposed CMCA to meet evaluation requirements of ventilation system is verified.展开更多
Static aerobic composting of municipal sewage sludge with forced ventilation or air ventilation using matured compost as bulking conditioner was investigated. Physical and chemical parame ,eters, e.g., temperature, mo...Static aerobic composting of municipal sewage sludge with forced ventilation or air ventilation using matured compost as bulking conditioner was investigated. Physical and chemical parame ,eters, e.g., temperature, moisture content, VSS, CODcr, pH, and germination index (GI), were analyzed to characterize the composting process. Fermentation starts quickly in both forced and air ventilation compost heaps and reaches high-temperature stage after 2 d, owing to the bulking function of matured compost. Compared to air ventilation, however, forced ventilation enables the high-temperature stage to last longer for approximately 7 d. The moisture content of both compost bodies decreases from 62% to about 50% as a result of evaporation, and it decreases slightly faster in forced ventilation compost heap after 13 d due to the higher temperature and better ventilation condition. Although no obvious differences of VSS and pH are observed between both compost heaps, the soluble CODcr and GI show differences during the second half period of fermentation. In forced ventilation compost, the soluble CODcr has a small rebound after 13 d, and GI decreases from 46% to 35% but then increases. These results show that in general, the matured compost is a good conditioner and force ventilation with a proper air supply strategy can be more efficient than air ventilation.展开更多
Natural ventilation is driven by either buoyancy forces or wind pressure forces or their combinations that inherit stochastic variation into ventilation rates. Since the ventilation rate is a nonlinear function of mul...Natural ventilation is driven by either buoyancy forces or wind pressure forces or their combinations that inherit stochastic variation into ventilation rates. Since the ventilation rate is a nonlinear function of multiple variable factors including wind speed, wind direction, internal heat source and building structural thermal mass, the conventional methods for quantifying ventilation rate simply using dominant wind direction and average wind speed may not accurately describe the characteristic performance of natural ventilation. From a new point of view, the natural ventilation performance of a single room building under fluctuating wind speed condition using the Monte-Carlo simulation approach was investigated by incorporating building facade thermal mass effect. Given a same hourly turbulence intensity distribution, the wind speeds with 1 rain frequency fluctuations were generated using a stochastic model, the modified GARCH model. Comparisons of natural ventilation profiles, effective ventilation rates, and air conditioning electricity use for a three-month period show statistically significant differences (for 80% confidence interval) between the new calculations and the traditional methods based on hourly average wind speed.展开更多
A numerical study is carried out on particle deposition in ducts with either convex or concave wall cavity.Results show that,if compared with smooth duct,particle deposition velocitiesVd^+increase greatly in ducts wit...A numerical study is carried out on particle deposition in ducts with either convex or concave wall cavity.Results show that,if compared with smooth duct,particle deposition velocitiesVd^+increase greatly in ducts with wall cavities.More specifically,forτ+<1,Vd^+increase by about 2–4 orders of magnitude in the cases with the convex and concave wall cavities;forτ+>1,Vd^+grows relatively slower.Enhancement of particle deposition with wall cavities is caused by the following mechanisms,i.e.,interception by the wall cavities,expanded deposition area,and the enhanced flow turbulence.In general,addition of wall cavities is contributive for particle deposition,so it provides an efficient approach to remove particles,especially with small size,e.g.,PM2.5.Moreover,the convex wall cavity leads to a larger increment ofVd^+than the concave wall cavity.However,taking pressure loss into account,thoughVd^+is relatively lower,duct with the concave wall cavity is more efficient than that with the convex wall cavity.展开更多
Ventilation is an effective solution for improving indoor air quality and reducing airborne transmission.Buildings need sufficient ventilation to maintain a low infection risk but also need to avoid an excessive venti...Ventilation is an effective solution for improving indoor air quality and reducing airborne transmission.Buildings need sufficient ventilation to maintain a low infection risk but also need to avoid an excessive ventilation rate,which may lead to high energy consumption.The Wells-Riley(WR)model is widely used to predict infection risk and control the ventilation rate.However,few studies compared the non-steady-state(NSS)and steady-state(SS)WR models that are used for ventilation control.To fill in this research gap,this study investigates the effects of the mechanical ventilation control strategies based on NSS/SS WR models on the required ventilation rates to prevent airborne transmission and related energy consumption.The modified NSS/SS WR models were proposed by considering many parameters that were ignored before,such as the initial quantum concentration.Based on the NSS/SS WR models,two new ventilation control strategies were proposed.A real building in Canada is used as the case study.The results indicate that under a high initial quantum concentration(e.g.,0.3 q/m^(3))and no protective measures,SS WR control underestimates the required ventilation rate.The ventilation energy consumption of NSS control is up to 2.5 times as high as that of the SS control.展开更多
To explore the spatial-temporal evolution law of rock mass temperature in high geothermal roadway during mechar^ical ventilation, a series of experiments were conducted based on the physical simulation test system of ...To explore the spatial-temporal evolution law of rock mass temperature in high geothermal roadway during mechar^ical ventilation, a series of experiments were conducted based on the physical simulation test system of thermal and humid environment in high geothermal roadway, which is a method independently developed by China University of Mining and Technology. The results indicate that during ventilation, the disturbed region of the temperature extends gradually from shallow area to deep area in the surrounding rock mass of the roadway. Meanwhile, the temperature increases as the exponential function from shallow area to deep, with steady decrease of the temperature gradient and heat flux. As the ventilation proceeds, the relationship between dimensionless temperature and dimensionless time approximately meets Hill function.展开更多
The temporal variation of ventilation coefficient was estimated and a simple model for the prediction of urban ventilation coefficient in Changsha was developed. Firstly, Pearson correlation analysis was used to inves...The temporal variation of ventilation coefficient was estimated and a simple model for the prediction of urban ventilation coefficient in Changsha was developed. Firstly, Pearson correlation analysis was used to investigate the relationship between meteorological parameters and mixing layer height during 2005-2009 in Changsha, China. Secondly, the multi-linear regression model between daytime and nighttime was adopted to predict the temporal ventilation coefficient. Thirdly, the validation of the model between the predicted and observed ventilation coefficient in 2010 was conducted. The results showed that ventilation coefficient significantly varied and remained high during daytime, while it stayed relatively constant and low during nighttime. In addition, the diurnal ventilation coefficient was distinctly negatively correlated with PM10 (particle with the diameter less than 10 μm) concentration in Changsha, China. The predicted ventilation coefficient agreed well with the observed values based on the multi-linear regression models during daytime and nighttime. The urban temporal ventilation coefficient could be accurately predicted by some simple meteorological parameters during daytime and nighttime. The ventilation coefficient played an important role in the PM10 concentration level.展开更多
Depending on the numerical test approach on a computer, the relationships among relevant parameters, eg branch number, node number, mesh number, computation accuracy, preliminary value of airflow rate, iteration numbe...Depending on the numerical test approach on a computer, the relationships among relevant parameters, eg branch number, node number, mesh number, computation accuracy, preliminary value of airflow rate, iteration number, computation time and convergence in a mine ventilation network analysis, were investigated based on 5 mine ventilation systems. The results show that a higher computation accuracy greatly influences the iteration number. When the accuracy reaches 10-6m3·s-1 for solving a complicated mine ventilation network, the running time is too long though a high-speed computer is used. The preliminary value of airflow rate in the range of 1100m3·s-1 has little effects the iteration number. The structure of network also has some effect on the iteration number.展开更多
The effects of vents on thermal ventilation to save energy in the cold rolling workshop of Baosteel were investigated.According to the scale modeling theory,a small chamber was established.The details about constructi...The effects of vents on thermal ventilation to save energy in the cold rolling workshop of Baosteel were investigated.According to the scale modeling theory,a small chamber was established.The details about construction of experiment on thermal ventilation and the preparation and arrangement of apparatus were discussed,and then the effects of vents on thermal ventilation were studied through experiments,which includes the temperature distribution,the volume of ventilation,the temperature difference between inlets and outlets,the neutral plane,and the effective thermal coefficient of thermal natural ventilation.Based on this,the effects of natural ventilation based on varied area of inlets and outlets and those of vents on one side and on different sides were compared.According to the experiments,the area of inlet vents and outlet vents affect the temperature distribution in chamber,and their effects on ventilation volume are different,but the effects of vents in single side or different sides are the same under the condition that only thermal ventilation is considered.展开更多
Making the use of ventilation technology may decrease building energy consumption,improve indoor thermal environment,and ameliorate indoor air quality. Combining with the meteorological characteristics in the Changjia...Making the use of ventilation technology may decrease building energy consumption,improve indoor thermal environment,and ameliorate indoor air quality. Combining with the meteorological characteristics in the Changjiang river valley and focusing on Chongqing,this work makes an applied analysis of the feasibility of intermittent mechanical ventilation. By comparison of various ventilation modes,it gives a summary of the suitable ventilation ways for different weather conditions with the combination of testing data and experimental data.展开更多
This paper investigated the natural ventilation driven by hot pressure on a typical office building with single window opening.The actual result indicates that the ventilation rate of natural ventilation driven by hot...This paper investigated the natural ventilation driven by hot pressure on a typical office building with single window opening.The actual result indicates that the ventilation rate of natural ventilation driven by hot pressure in the actual single window opening construction is very different from that obtained by the theoretical formula,since the ventilation conditions between actual environment and ventilation driven by hot pressure in the single window opening are different.Therefore,the theoretical formula is amended,and it becomes more consistent with the actual ventilation rate of natural ventilation driven by hot pressure under conditions that the construction is in the form of single window opening.展开更多
Nowadays,the world is short of energy source,and larger proportion of building energy consumption is occupied by air conditioning system. It is urgent that not only importance should be attached on energy saving but a...Nowadays,the world is short of energy source,and larger proportion of building energy consumption is occupied by air conditioning system. It is urgent that not only importance should be attached on energy saving but also arcology energy technology based on green and sustainable thought should be advocated. Considering the ever growing energy consumption of residential buildings,intermittent ventilation is a solution to saving energy consumption and improving indoor thermal comfort. Aiming at reducing indoor air temperature by intermittent ventilation and decrease energy consumption of air conditioning system,with the help of DeST (Designer's Simulation Toolkit) this paper analyzes the characteristics of air conditioning load and year round air conditioning time in Chongqing located in hot summer and cold winter zone,obtains the amount of energy consumption saved at different ventilation rates,and recommends suitable ventilation rate in hot summer and cold winter zone.展开更多
The current ventilation condition of the hot and humid regions was analyzed through on-site investigation. It is found that residents in this region expect to improve indoor thermal environment through natural ventila...The current ventilation condition of the hot and humid regions was analyzed through on-site investigation. It is found that residents in this region expect to improve indoor thermal environment through natural ventilation as much as possible. Then,it comes to a conclusion by the field test that natural ventilation has certain practical effect on improving indoor thermal environment. CFD simulation software is employed to verify the test result. Based on PMV modified model,and according to norms,geography and climate combined with the measured and simulated results,the application of the time and effectiveness of natural ventilation in hot and humid region were analyzed,to some extent,providing a basis for reducing the air-conditioner's runtime with natural ventilation.展开更多
文摘With different structural forms of ventilation pipes have various attenuation effects on incident shock waves while meeting ventilation requirements.The attenuation mechanism and the propagation law of shock waves in ventilation pipes of different structures are investigated by experiments and numerical simulations.Furthermore,for the same structure,the effects of peak pressure and positive pressure time on the attenuation rate are discussed.It is found that the attenuation rate increases with the incident shock wave pressure,and the shock wave attenuation rate tends to reach its limiting value k for the same structure and reasonably short positive pressure time.Under the same conditions,the attenuation rate is calculated using the pressure of the shock wave as follows:diffusion chamber pipe,branch pipe and selfconsumption pipe;the attenuation rate per unit volume is calculated as follows:self-consumption pipe,branch pipe and diffusion chamber pipe.In addition,an easy method is provided to calculate the attenuation rate of the shock wave in single and multi-stage ventilation pipes.Corresponding parameters are provided for various structures,and the margin of error between the formulae and experimental results is within 10%,which is significant for engineering applications.
基金Project(N2022G031)supported by the Science and Technology Research and Development Program Project of China RailwayProjects(2022-Key-23,2021-Special-01A)supported by the Science and Technology Research and Development Program Project of China Railway Group LimitedProject(52308419)supported by the National Natural Science Foundation of China。
文摘The breakage and bending of ducts result in a difficulty to cope with ventilation issues in bidirectional excavation tunnels with a long inclined shaft using a single ventilation method based on ducts.To discuss the hybrid ventilation system applied in bidirectional excavation tunnels with a long inclined shaft,this study has established a full-scale computational fluid dynamics model based on field tests,the Poly-Hexcore method,and the sliding mesh technique.The distribution of wind speed,temperature field,and CO in the tunnel are taken as indices to compare the ventilation efficiency of three ventilation systems(duct,duct-ventilation shaft,duct–ventilated shaft-axial fan).The results show that the hybrid ventilation scheme based on duct-ventilation shaft–axial fan performs the best among the three ventilation systems.Compared to the duct,the wind speed and cooling rate in the tunnel are enhanced by 7.5%–30.6%and 14.1%–17.7%,respectively,for the duct-vent shaft-axial fan condition,and the volume fractions of CO are reduced by 26.9%–73.9%.This contributes to the effective design of combined ventilation for bidirectional excavation tunnels with an inclined shaft,ultimately improving the air quality within the tunnel.
文摘Because of the multiple problems on high energy consumption and unbalanced thermal comfort caused by the traditional ventilation system,a new concept of ventilation-stratum ventilation has been proposed,which sends the fresh air to the breathing zone directly.In this paper,the local air distributions of the displacement ventilation and the stratum ventilation in a model office were measured.The air ages in the breathing zone for the displacement ventilation and stratum ventilation were compared with the tracer gas concentration decay method.The decay curves of tracer gas concentration for these two ventilation systems in the breathing zone were obtained,and the air ages were calculated.The experimental results show that the stratum ventilation system can offer lower air age for four mechanically ventilated cases in the breathing zone,and it can also provide better thermal comfort,which renews the air of breathing zone more quickly and reduces the energy consumption in some degree.The experimental investigation provides a theoretical basis for the application of stratum ventilation system.
基金Project(51874016)supported by the National Natural Science Foundation of China。
文摘In order to control the dust pollution produced by air leg rock drill in the trolley area during the excavation of long-distance single ended tunnel,the full-scale physical model of working face was established by using FLUENT software,and the numerical simulation analysis of tunnel drilling ventilation and dust removal parameters was carried out.The results show that it is difficult to control the dust pollution of the face by conventional ventilation,and the drilling dust is distributed in the range of 10 m from the face;after the introduction of the long pressure and short suction ventilation scheme,when the ratio of compressed air volume to exhaust air volume is 0.72,the height of the pressure fan is 2.5 m,the distance between the pressure fan and the palm face is 20 m,and the exhaust fan is 12 m away from the palm,the dust concentration control efficiency of the working face is increased by about 60%.Therefore,in the similar long-distance single head tunnel construction,it is appropriate to adopt the dust removal method of long-distance short suction and exhaust fan to ensure the working environment.
基金Projects(51504286,51374242)supported by the National Natural Science Foundation of ChinaProject(2015M572270)supported by China Postdoctoral Science FoundationProject(2015RS4004)supported by the Science and Technology Plan of Hunan Province,China
文摘The current popular methods for decision making and project optimisation in mine ventilation contain a number of deficiencies as they are solely based on either subjective knowledge or objective information.This paper presents a new approach to rank the alternatives by G1-coefficient of variation method.The focus of this approach is the use of the combination weighing,which is able to compensate for the deficiencies in the method of evaluation index single weighing.In the case study,an appropriate evaluation index system was established to determine the evaluation value of each ventilation mode.Then the proposed approach was used to select the best development face ventilation mode.The result shows that the proposed approach is able to rank the alternative development face ventilation mode reasonably,the combination weighing method had the advantages of both subjective and objective weighing methods in that it took into consideration of both the experience and wisdom of experts,and the new changes in objective conditions.This approach provides a more reasonable and reliable procedure to analyse and evaluate different ventilation modes.
文摘The 1/15 reduced-scale experiments using Froude scaling were designed to study the effect on the smoke control efficiency for subway tunnel fires with natural ventilation mode.The propane gas fires with heat release rate 11.48 kW was used,which corresponds to the heat release rate 10 MW in the full-scale tunnel.The temperature distributions under the ceiling were measured by K-type thermocouples to investigate smoke movement,and the velocity of smoke in shafts was measured by hot-wire anemometer to obtain the smoke extract amount of ventilation shafts.The results show that the smoke temperature under the ceiling varies with the longitudinal different distance from fire source.The results also show that the smoke temperature distributions and the smoke control efficiency in tunnel vary with the space between ventilation shafts and vary with the area and the height of ventilation shaft.
基金Project(2018YFC0808404)supported by National Key Research and Development Program of China。
文摘Ventilation system is significant in underground metal mine of alpine region.Reasonable evaluation of ventilation effectiveness will lead to a practical improvement for the maintenance and management of ventilation system.However,it is difficult to make an effective evaluation of ventilation system due to the lack of classification criteria with respect to underground metal mine in alpine region.This paper proposes a novel evaluation method called the cloud model-clustering analysis(CMCA).Cloud model(CM)is utilized to process collected data of ventilation system,and they are converted into cloud descriptors by CM.Cloud similarity(CS)based Euclidean distance(ED)is proposed to make clustering analysis of assessed samples.Then the classification of assessed samples will be identified by clustering analysis results.A case study is developed based on CMCA.Evaluation results show that ventilation effectiveness can be well classified.Moreover,CM is used alone to make comparison of evaluation results obtained by CMCA.Then the availability and validity of CMCA is verified.Meanwhile,difference of CS based ED and classical ED is analyzed.Two new clustering analysis methods are introduced to make comparison with CMCA.Then the ability of proposed CMCA to meet evaluation requirements of ventilation system is verified.
基金Projects(50978087,50908081)supported by the National Natural Science Foundation of China
文摘Static aerobic composting of municipal sewage sludge with forced ventilation or air ventilation using matured compost as bulking conditioner was investigated. Physical and chemical parame ,eters, e.g., temperature, moisture content, VSS, CODcr, pH, and germination index (GI), were analyzed to characterize the composting process. Fermentation starts quickly in both forced and air ventilation compost heaps and reaches high-temperature stage after 2 d, owing to the bulking function of matured compost. Compared to air ventilation, however, forced ventilation enables the high-temperature stage to last longer for approximately 7 d. The moisture content of both compost bodies decreases from 62% to about 50% as a result of evaporation, and it decreases slightly faster in forced ventilation compost heap after 13 d due to the higher temperature and better ventilation condition. Although no obvious differences of VSS and pH are observed between both compost heaps, the soluble CODcr and GI show differences during the second half period of fermentation. In forced ventilation compost, the soluble CODcr has a small rebound after 13 d, and GI decreases from 46% to 35% but then increases. These results show that in general, the matured compost is a good conditioner and force ventilation with a proper air supply strategy can be more efficient than air ventilation.
文摘Natural ventilation is driven by either buoyancy forces or wind pressure forces or their combinations that inherit stochastic variation into ventilation rates. Since the ventilation rate is a nonlinear function of multiple variable factors including wind speed, wind direction, internal heat source and building structural thermal mass, the conventional methods for quantifying ventilation rate simply using dominant wind direction and average wind speed may not accurately describe the characteristic performance of natural ventilation. From a new point of view, the natural ventilation performance of a single room building under fluctuating wind speed condition using the Monte-Carlo simulation approach was investigated by incorporating building facade thermal mass effect. Given a same hourly turbulence intensity distribution, the wind speeds with 1 rain frequency fluctuations were generated using a stochastic model, the modified GARCH model. Comparisons of natural ventilation profiles, effective ventilation rates, and air conditioning electricity use for a three-month period show statistically significant differences (for 80% confidence interval) between the new calculations and the traditional methods based on hourly average wind speed.
基金Project (51506069) supported by the National Natural Science Foundation of ChinaProject (2016YFB0600605) supported by the National Key Research and Development Program of ChinaProjects (HUST2016YXMS286,HUST2015061) supported by the Fundamental Research Funds for the Central Universities,China
文摘A numerical study is carried out on particle deposition in ducts with either convex or concave wall cavity.Results show that,if compared with smooth duct,particle deposition velocitiesVd^+increase greatly in ducts with wall cavities.More specifically,forτ+<1,Vd^+increase by about 2–4 orders of magnitude in the cases with the convex and concave wall cavities;forτ+>1,Vd^+grows relatively slower.Enhancement of particle deposition with wall cavities is caused by the following mechanisms,i.e.,interception by the wall cavities,expanded deposition area,and the enhanced flow turbulence.In general,addition of wall cavities is contributive for particle deposition,so it provides an efficient approach to remove particles,especially with small size,e.g.,PM2.5.Moreover,the convex wall cavity leads to a larger increment ofVd^+than the concave wall cavity.However,taking pressure loss into account,thoughVd^+is relatively lower,duct with the concave wall cavity is more efficient than that with the convex wall cavity.
基金Project(RGPIN-2019-05824)supported by the Start-up Fund of Universitéde Sherbrooke and Discovery Grants of Natural Sciences and Engineering Research Council of Canada(NSERC)。
文摘Ventilation is an effective solution for improving indoor air quality and reducing airborne transmission.Buildings need sufficient ventilation to maintain a low infection risk but also need to avoid an excessive ventilation rate,which may lead to high energy consumption.The Wells-Riley(WR)model is widely used to predict infection risk and control the ventilation rate.However,few studies compared the non-steady-state(NSS)and steady-state(SS)WR models that are used for ventilation control.To fill in this research gap,this study investigates the effects of the mechanical ventilation control strategies based on NSS/SS WR models on the required ventilation rates to prevent airborne transmission and related energy consumption.The modified NSS/SS WR models were proposed by considering many parameters that were ignored before,such as the initial quantum concentration.Based on the NSS/SS WR models,two new ventilation control strategies were proposed.A real building in Canada is used as the case study.The results indicate that under a high initial quantum concentration(e.g.,0.3 q/m^(3))and no protective measures,SS WR control underestimates the required ventilation rate.The ventilation energy consumption of NSS control is up to 2.5 times as high as that of the SS control.
基金Project(2014-6121)supported by Fundamental Research Funds for the Central Universities,ChinaProject(51504236)supported by the National Natural Science Foundation of ChinaProject supported by the Priority Academic Program Development of Jiangsu Higher Education Institutions,China
文摘To explore the spatial-temporal evolution law of rock mass temperature in high geothermal roadway during mechar^ical ventilation, a series of experiments were conducted based on the physical simulation test system of thermal and humid environment in high geothermal roadway, which is a method independently developed by China University of Mining and Technology. The results indicate that during ventilation, the disturbed region of the temperature extends gradually from shallow area to deep area in the surrounding rock mass of the roadway. Meanwhile, the temperature increases as the exponential function from shallow area to deep, with steady decrease of the temperature gradient and heat flux. As the ventilation proceeds, the relationship between dimensionless temperature and dimensionless time approximately meets Hill function.
基金Project(51178466) supported by the National Natural Science Foundation of ChinaProject(FANEDD200545) supported by Foundation for the Author of National Excellent Doctoral Dissertation of ChinaProject(2011JQ006) supported by Fundamental Research Funds of the Central Universities of China
文摘The temporal variation of ventilation coefficient was estimated and a simple model for the prediction of urban ventilation coefficient in Changsha was developed. Firstly, Pearson correlation analysis was used to investigate the relationship between meteorological parameters and mixing layer height during 2005-2009 in Changsha, China. Secondly, the multi-linear regression model between daytime and nighttime was adopted to predict the temporal ventilation coefficient. Thirdly, the validation of the model between the predicted and observed ventilation coefficient in 2010 was conducted. The results showed that ventilation coefficient significantly varied and remained high during daytime, while it stayed relatively constant and low during nighttime. In addition, the diurnal ventilation coefficient was distinctly negatively correlated with PM10 (particle with the diameter less than 10 μm) concentration in Changsha, China. The predicted ventilation coefficient agreed well with the observed values based on the multi-linear regression models during daytime and nighttime. The urban temporal ventilation coefficient could be accurately predicted by some simple meteorological parameters during daytime and nighttime. The ventilation coefficient played an important role in the PM10 concentration level.
基金Project (50474050) supported by the National Natural Science Foundation of China
文摘Depending on the numerical test approach on a computer, the relationships among relevant parameters, eg branch number, node number, mesh number, computation accuracy, preliminary value of airflow rate, iteration number, computation time and convergence in a mine ventilation network analysis, were investigated based on 5 mine ventilation systems. The results show that a higher computation accuracy greatly influences the iteration number. When the accuracy reaches 10-6m3·s-1 for solving a complicated mine ventilation network, the running time is too long though a high-speed computer is used. The preliminary value of airflow rate in the range of 1100m3·s-1 has little effects the iteration number. The structure of network also has some effect on the iteration number.
文摘The effects of vents on thermal ventilation to save energy in the cold rolling workshop of Baosteel were investigated.According to the scale modeling theory,a small chamber was established.The details about construction of experiment on thermal ventilation and the preparation and arrangement of apparatus were discussed,and then the effects of vents on thermal ventilation were studied through experiments,which includes the temperature distribution,the volume of ventilation,the temperature difference between inlets and outlets,the neutral plane,and the effective thermal coefficient of thermal natural ventilation.Based on this,the effects of natural ventilation based on varied area of inlets and outlets and those of vents on one side and on different sides were compared.According to the experiments,the area of inlet vents and outlet vents affect the temperature distribution in chamber,and their effects on ventilation volume are different,but the effects of vents in single side or different sides are the same under the condition that only thermal ventilation is considered.
基金Projects(2006BAJ02A02-052006BAJ01A05-06-04) supported by the National Key Technology R&D Program of China
文摘Making the use of ventilation technology may decrease building energy consumption,improve indoor thermal environment,and ameliorate indoor air quality. Combining with the meteorological characteristics in the Changjiang river valley and focusing on Chongqing,this work makes an applied analysis of the feasibility of intermittent mechanical ventilation. By comparison of various ventilation modes,it gives a summary of the suitable ventilation ways for different weather conditions with the combination of testing data and experimental data.
基金Supported by "Eleventh Five-Year" National Scientific and Technological Support Scheme Funded Projects(2006BAJ02A02,2006BAJ02A05)Ministry of Education,the New Century Talents Scheme Funded Projects(Education and Technology Divi-sion[2007]No.209)National Personnel Merit-Based Projects(Office of Hair People[2007]170)
文摘This paper investigated the natural ventilation driven by hot pressure on a typical office building with single window opening.The actual result indicates that the ventilation rate of natural ventilation driven by hot pressure in the actual single window opening construction is very different from that obtained by the theoretical formula,since the ventilation conditions between actual environment and ventilation driven by hot pressure in the single window opening are different.Therefore,the theoretical formula is amended,and it becomes more consistent with the actual ventilation rate of natural ventilation driven by hot pressure under conditions that the construction is in the form of single window opening.
基金Projects(2006BAJ02A02-05,2006BAJ01A05-06-04) supported by the National Key Technologies R & D Program of China
文摘Nowadays,the world is short of energy source,and larger proportion of building energy consumption is occupied by air conditioning system. It is urgent that not only importance should be attached on energy saving but also arcology energy technology based on green and sustainable thought should be advocated. Considering the ever growing energy consumption of residential buildings,intermittent ventilation is a solution to saving energy consumption and improving indoor thermal comfort. Aiming at reducing indoor air temperature by intermittent ventilation and decrease energy consumption of air conditioning system,with the help of DeST (Designer's Simulation Toolkit) this paper analyzes the characteristics of air conditioning load and year round air conditioning time in Chongqing located in hot summer and cold winter zone,obtains the amount of energy consumption saved at different ventilation rates,and recommends suitable ventilation rate in hot summer and cold winter zone.
基金Project(50838009) supported by the National Natural Science Foundation of ChinaProject(2006BAJ01A05) supported by the National Key Technologies R&D Program of ChinaProject(CSTC,2008AB7110) supported by Key Technologies R & D Program of Chongqing City,China
文摘The current ventilation condition of the hot and humid regions was analyzed through on-site investigation. It is found that residents in this region expect to improve indoor thermal environment through natural ventilation as much as possible. Then,it comes to a conclusion by the field test that natural ventilation has certain practical effect on improving indoor thermal environment. CFD simulation software is employed to verify the test result. Based on PMV modified model,and according to norms,geography and climate combined with the measured and simulated results,the application of the time and effectiveness of natural ventilation in hot and humid region were analyzed,to some extent,providing a basis for reducing the air-conditioner's runtime with natural ventilation.