A data acquisition system (DAS) to implement high-speed, real-time and multi-channel data acquisition and store is presented. The control of the system is implemented by the combination of complex programable logic ...A data acquisition system (DAS) to implement high-speed, real-time and multi-channel data acquisition and store is presented. The control of the system is implemented by the combination of complex programable logic device (CPLD) and digital signal processing (DSP), the bulk buffer of the system is implemented by the combination of CPLD, DSP, and synchronous dynamic random access memory (SDRAM), and the data transfer is implemented by the combination of DSP, first in first out (FIFO), universal serial bus (USB) and USB hub. The system could not only work independently in single-channel mode, but also implement high-speed real-time multi-channel data acquisition system (MCDAS) by the combination of multiple single-channels. The sampling rate and data storage capacity of each channel could reach up to 100 million sampiing per second and 256 MB respectively.展开更多
This article describes the data processing and acquisition system for the HT-7 mul-tipulse Thomson scattering diagnostic. An eight-pulse laser is used in the Thomson scattering system to obtain electron temperature pr...This article describes the data processing and acquisition system for the HT-7 mul-tipulse Thomson scattering diagnostic. An eight-pulse laser is used in the Thomson scattering system to obtain electron temperature profiles at eight different times throughout an entire plasma discharge. The major components of the diagnostic system consist of a multipulse Nd-glass laser, a photodetector's subsystem, a calibration set and a CAMAC data processing and acquisition system. The data processing software along with LeCroy 2250L will perform the data acquisition. In order to simplify the operation and extend the capability of its compatibility with other math softwares, the processing software has been improved by the authors. The new software based on the VC++ easily utilizes some math softwares to calculate the electron temperature. The new software is simpler and more operational than the old one.展开更多
A multi-channel retarding field analyzer(MC-RFA) including two RFA modules and two Langmuir probes to measure the ion and electron temperature profiles within the scrape-off layer was developed for investigations of...A multi-channel retarding field analyzer(MC-RFA) including two RFA modules and two Langmuir probes to measure the ion and electron temperature profiles within the scrape-off layer was developed for investigations of the interplay between magnetic topology and plasma transport at the plasma boundary.The MC-RFA probe for the stellarator W7-X and first measurements at the tokamak EAST was designed.The probe head allows simultaneous multichannel ion temperature as well as for electron temperature measurements.The usability for radial correlation measurements of the measured ion currents is also given.展开更多
文摘A data acquisition system (DAS) to implement high-speed, real-time and multi-channel data acquisition and store is presented. The control of the system is implemented by the combination of complex programable logic device (CPLD) and digital signal processing (DSP), the bulk buffer of the system is implemented by the combination of CPLD, DSP, and synchronous dynamic random access memory (SDRAM), and the data transfer is implemented by the combination of DSP, first in first out (FIFO), universal serial bus (USB) and USB hub. The system could not only work independently in single-channel mode, but also implement high-speed real-time multi-channel data acquisition system (MCDAS) by the combination of multiple single-channels. The sampling rate and data storage capacity of each channel could reach up to 100 million sampiing per second and 256 MB respectively.
基金The project supported by the National Science Foundation of China(No.10075049 and No.10275068)
文摘This article describes the data processing and acquisition system for the HT-7 mul-tipulse Thomson scattering diagnostic. An eight-pulse laser is used in the Thomson scattering system to obtain electron temperature profiles at eight different times throughout an entire plasma discharge. The major components of the diagnostic system consist of a multipulse Nd-glass laser, a photodetector's subsystem, a calibration set and a CAMAC data processing and acquisition system. The data processing software along with LeCroy 2250L will perform the data acquisition. In order to simplify the operation and extend the capability of its compatibility with other math softwares, the processing software has been improved by the authors. The new software based on the VC++ easily utilizes some math softwares to calculate the electron temperature. The new software is simpler and more operational than the old one.
基金funding from the Euratom research and training programme 2014–2018 under grant agreement No.633053supported by the National Magnetic Confinement Fusion Science Program of China under Contracts No.20113GB106003
文摘A multi-channel retarding field analyzer(MC-RFA) including two RFA modules and two Langmuir probes to measure the ion and electron temperature profiles within the scrape-off layer was developed for investigations of the interplay between magnetic topology and plasma transport at the plasma boundary.The MC-RFA probe for the stellarator W7-X and first measurements at the tokamak EAST was designed.The probe head allows simultaneous multichannel ion temperature as well as for electron temperature measurements.The usability for radial correlation measurements of the measured ion currents is also given.